Sincerus Florida, LLC
Pompano Beach, Florida, United States
FEI 3012384835
FDA has 6 inspections on file for Sincerus Florida, LLC in Pompano Beach, Florida (FEI 3012384835), from 2016 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Jul 15, 2016. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.192 and FDCA 503B(a)(10)(B).
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 6, 2016–2026
- 1 OAI · 4 VAI · 0 NAI
- Inspections with 483 observations shown
- 6 of 6
- 2 posted 483s not matched to an inspection
- Requested under FOIA
- 2 requests, latest Jul 21, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetClassification not posted yetPosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate smoke visualization validation
OBSERVATION 1 Procedures designed to prevent microbiological contamination include adequate validation of the aseptic process. 1) The following deficiencies were identified during October 2025 for the [illegible] ISO 5 Laminar Air Flow Hood (LAFH) used for 2 GM Magnesium Sulfate in 5% Dextrose 50 mL Bag Injection: a. Processes which occur during routine operations, such as removing stoppers and drawing 4 mL from the vial using a syringe, sanitizing [illegible] Port, injecting the contents of the syringe into the Dextrose bag, and placing an IV seal on each IV port after injection, were not simulated during the Dynamic Smoke Study. b. During the Dynamic Smoke Study, where the technician was performing operations within the LAFH, the operations could not be visualized. c. The set-up of environmental monitoring (EM) during the smoke study and the units were not turned on to visualize the flow pattern. 2) The following deficiencies were identified during May 2025 for the Cleanroom Suite and the [illegible] (Equipment ID: 00167) in which sterile 2 GM Magnesium Sulfate is produced: a. During the Dynamic Smoke Study, no smoke was positioned to visualize the syringe insertion into the Magnesium Sulfate vial to visualize the air flow pattern. b. Processes which occur during routine operations, such as removing stoppers, sanitizing each 5% Dextrose Bag Injection Port, placing an IV seal on each IV port, and injecting, were not simulated during the Dynamic Smoke Study.
- Observation 2
LAFH/HEPA physical defects
OBSERVATION 2 Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. The following deficiencies were identified during the review of the ISO 5 Laminar Air Flow Hood (LAFH) (Equipment ID: 00167) used for Magnesium Sulfate in 5% Dextrose 50 mL Bag Injection: 1) Scratches were observed on the HEPA filter grate on the left side of the ISO 5 LAFH. Additionally, a similar inward curve/indentation was observed in the Dynamic Smoke Study video which coincided with 5% Dextrose 50 mL Bag Injection Lots 74946 and 75101 compounded in the ISO 5 LAFH. 2) Cracks were observed on the interior of the ISO 5 LAFH. Additionally, similar cracks were observed in October 2025; 2 GM Magnesium Sulfate compounded in the ISO 5 LAFH on [illegible]. 3) Yellow stains that appeared to be sticky and glue-like were observed on the bottom of the HEPA filter grate that holds the HEPA filter in place, and discoloration was observed on the rod within the ISO 5 LAFH which is used to hang the 50 mL Dextrose bags. The firm has not characterized or identified the nature of these residues/potential contaminants. A review of the Compounding Batch Records for 2 GM Magnesium Sulfate in 5% Dextrose 50 mL Bag Injection Lots 74946 and 75101 revealed that line clearance procedures do not include instructions requiring compounding technicians to perform a visual inspection of the ISO 5 LAFH and HEPA filter integrity prior to initiating compounding operations.
Show observations 3 to 7
- Observation 3
No independent AQL testing
OBSERVATION 3 Acceptance criteria for the sampling and testing conducted on batches of drug products meet appropriate statistical quality control criteria as a condition for their approval and release. Specifically, the firm's Quality Unit does not perform independent Acceptable Quality Limit (AQL) sampling and testing of finished sterile drug products following 100% manual visual inspection. The firm's procedure # SC-03 "Visual Inspection of Compounded Sterile Preparations (CSPs)" does not include instructions for Quality Unit AQL sampling and testing. Without independent AQL testing by the Quality Unit, there is no objective, statistically sound evaluation of whether released product is essentially free of visible defects. Specifically, Sterile Drug Product 2 GM Magnesium Sulfate (Compounding Date: (b)(4); BUD: 08JAN2026; Batch Size: [illegible]; and (b)(4); BUD: 24JAN2026; Batch Size: [illegible]) was inspected and released following visual inspection performed solely by the same compounding technician who produced the respective lots, without any independent AQL sampling or testing performed by the Quality Unit prior to release for distribution.
- Observation 4
Inadequate visual inspection qualification
OBSERVATION 4 Your firm failed to establish adequate written procedures for production and process controls that assure the drug products have the identity, strength, purity, and quality they purport or possess. Specifically, the firm's procedure # SC-03 "Final Visual Inspection of Compounded Sterile Preparations (CSPs)" does not include instructions for creation and characterization of the Visual Inspection Qualification (defect) used in, and instructions for the qualification of, manual visual inspectors. The defect [illegible] designed on [illegible] and used to qualify manual visual inspectors contains defects of unknown size. No threshold studies (e.g., probability of detection studies) have been performed to determine whether the particulates encountered in the finished sterile drug product, and whether trained personnel can reproducibly detect them. As a result, there is no scientific basis for concluding that the compounding technician, who was qualified on [illegible], and who conducted the 100% visual inspection of Sterile Drug Product 2 GM Magnesium Sulfate in 5% Dextrose 50 mL Bag Injection Lot 74946 (Compounding Date: [illegible]) and Lot 75101 (Compounding Date: [illegible]), both of which were released for distribution, was adequately qualified to reliably detect visible particulates in the sterile drug product.
- Observation 5
Insufficient cleaning contact documentation
OBSERVATION 5 Written procedures are not established and followed for the cleaning of the equipment and utensils used in the manufacture, processing, packing or holding of drug products. The contact times maintained during the cleaning used for producing sterile drug product 2 GM Magnesium Sulfate in 5% Dextrose 50 mL Bag Injection (Compounding Date: [illegible]) and Lot 75101 were not documented. The firm's procedure # SC-17 "Sterile Compounding Area Cleaning and Disinfecting" specifies a required minimum contact time of [illegible] and [illegible]; however, the contact times are not recorded in the compounding batch records or cleaning logs and the firm does not have documentation of the contact time.
- Observation 6
Complaint and change control failures
OBSERVATION 6 The responsibilities and procedures applicable to complaint handling, investigations, and Quality Unit review are inadequate. Specifically: 1) No assessment of retain samples, batch records, or laboratory testing data was performed for the below listed complaints, as required by the firm's procedure "Customer Complaints" and Management Steps 7.6.1 and 7.6.3 which state that Quality investigates whether the compounded product may have resulted in a Quality Non-Adverse Event, Adverse Event, or Serious Adverse Event and retains samples and Quality checks respectively. a. Complaint # CR25-540 (SKU: 031098; Product: Holixia Solution; Lot # 71065): Patient Complaint Description: Severe migraines and causing scalp to burn/itch. b. Complaint # CR25-389 (SKU: 031098; Product: Holixia Solution; Lot # 71065): Patient Complaint Description: Redness on the skin/itchy scalp. c. Complaint # CR25-365 (SKU: 031098; Product: Holixia Solution; Lot # 71466): Patient Complaint Description: Bumps on scalp; she felt "bumps" on her scalp. d. Complaint # CR25-538 (SKU: 141057; Product: Melidu Emulsion; Lot # 71829): Patient Complaint Description: Prescription makes her eye swell up. e. Complaint # CR25-530 (SKU: 141057; Product: Melidu Emulsion; Lot # 71466): Patient Complaint Description: Prescription made face red and itchy. f. Complaint # CR25-708a (SKU: 011554; Product: Diasoxia Cream; Lot # 73139): Patient Complaint Description: Patient complaint about product texture hurting when they rub on their skin. g. Complaint # CR25-708b (SKU: 011554; Product: Diasoxia Cream; Lot # 73139): Patient Complaint Description: Patient complaint about product texture hurting when they rub on their skin. 2) No formal risk and product impact assessment for changes implemented under Planned Deviation #25-37: Planned Deviation #25-37 (issued 18JUL2025) was initiated to allow the compounding department to: (i) substitute [illegible] 5-Fluorouracil API and (ii) eliminate the [illegible], resulting in alterations to both the drug substance form and the validated manufacturing process. No formal risk or product impact assessment documenting the potential effect on identity, strength, or purity was performed prior to release of Lots 73314, 73316, and 73325, manufactured under this deviation, for distribution. 3) Inadequate corrective action for analyst error was identified for an out-of-specification result for FLU20250 ISM (QC25-5918) failing [illegible]. Reanalysis was performed on 12DEC2025 by the same analyst who conducted the initial failing analysis, yielding a passing result of 0.96227. Although analyst error was identified as the root cause, no retraining was implemented as a corrective and preventive action (CAPA). 4) The Quality Unit has not conducted a documented review of the third-party vendor for either the May 2025 or October 2025 smoke visualization studies, and the Quality Unit did not evaluate the adequacy of the smoke visualization studies prior to the manufacture of Sterile Drug Product 2 GM Magnesium Sulfate in 5% Dextrose 50 mL Bag Injection Lots 74946 and 75101. The firm does not have an established written procedure governing the review of smoke visualization studies conducted by the third-party vendor.
- Observation 7
No testing for objectionable microorganisms
OBSERVATION 7 Procedures designed to prevent objectionable microorganisms are not established, written, or followed. Specifically, the firm's non-sterile topical drug products and water-containing products are not routinely tested for objectionable microorganisms such as Burkholderia cepacia complex (BCC). Water is used as an ingredient in the formulation of several non-sterile products, including Clobetasol Propionate 0.05%/Niacinamide 4% Emulsion and other topical products. Additionally, the firm's procedure # TM-47 "Microbial Analysis of [illegible]" does not require testing of the [illegible] Water for BCC.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
- FDCA 501(a)(2)(A)
Beta-lactam, hazardous, highly potent drugs, prevention of cross-contamination
Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination.
- FDCA 503B(a)(10)(B)
Drug product container, fails to include
The container of your outsourcing facility's drug products does not include information required by section 503B(a)(10)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 503B(b)(2)(A)
Outsourcing facility, compounded drug report follow up
Your outsourcing facility did not submit a report to FDA identifying the drugs compounded during the previous six month period.
- FDCA 503B(a)(10)(B)
Drug product container, fails to include
The container of your outsourcing facility's drug products does not include information required by section 503B(a)(10)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Components withheld from use pending release
Each lot of components is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Mixing adequacy
The in process control procedures were deficient in that they did not include an examination of the adequacy of mixing to assure uniformity and homogeneity.
Show 1 more citation
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures are written, and followed
Procedures designed to assure that correct labeling and packaging materials are used for drug products are not written and followed.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
- FDCA 503B(a)(10)
Drug product label, outsourcer facility
The labels of your outsourcing facility’s drug products are deficient.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance1 citation published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Missing required product label information
The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A). Specifically, • The date the drug was compounded, dosage form, storage and handling conditions, list of inactive ingredients and the statement "Office use only" are not on your drug product labels. For example, labels for the following drug products do not contain the aforementioned: 1. Item# - - ROSACEA SILICONE GEL (IVERMECTIN 1%/METRONIDAZOLE 1%/NIACINAMIDE 4%/POTASSIUM AZELOYL DIGLYCINATE 5%), lot PC051716MNP 2. Item# - - ANTI-FUNGAL NAIL SOLUTION, 15ML (FLUCONAZOLE 4%/IBUPROFEN 2%/ITRACONAZOLE 1%/TERBINAFINE 4%), lot PC061416FUT 3. Item# - ROSACEA SILICONE GEL (NIACINAMIDE 2%/POTASSIUM AZELOYL DIGLYCINATE 15%), lot PC060616NP15 4. Item# - MELASMA EMULSION (HYDROCORTISONE 0.5%/HYDROQUINONE 8%/KOJIC ACID 4%/TRETINOIN 0.025%), lot PC0601316HH8K4T 5. Item# - MELASMA EMULSION (HYDROCORTISONE 0.5%/HYDROQUINONE 4%/KOJIC ACID 6%/TRETINOIN 0.025%/VITAMIN E 1%), lot PC061516HHKTE Your firm has produced approximately [illegible] types of product formulations and shipped approximately [illegible] units since registering as an outsourcing facility on March 10, 2016.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 21, 2026. Each one asked for a Form 483.
Inspection ending May 29, 2026Not classified yet
1 request. In the inspection history above. FDA has posted its Form 483.
- Jul 21, 2026FDA-FOIA-2026-6932Form 483· 1 of 4 sitesRecords released
Inspection ending May 23, 2024VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jul 25, 2024FDA-FOIA-2024-6551Form 483· 1 of 2 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.192Production record review2 of 4
- 21 CFR 211.67Equipment cleaning and maintenance1 of 4
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 4
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 4
- 21 CFR 211.113Control of microbiological contamination1 of 4
- 21 CFR 211.130Packaging and labeling operations1 of 4
- 21 CFR 211.165Testing and release for distribution1 of 4
- 21 CFR 211.166Stability testing1 of 4
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012384835 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012384835. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.