Colonia Care Pharmacy
515 Inman Ave Ste A, Colonia, New Jersey, United States
FEI 3012223534
FDA has 3 inspections on file for Colonia Care Pharmacy in Colonia, New Jersey (FEI 3012223534), from 2016 to 2021. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 3 citations from this inspection. They are listed below.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 3, 2016–2021
- 3 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 2 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Inadequate sporicidal agents, cleanroom and ISO 5 area
The use of sporicidal agents in the ISO 5 classified aseptic processing area was inadequate and infrequent.
- FDCA 501(a)(2)(A)
Highly potent drugs, prevention of cross-contamination
You produced highly potent drugs without providing adequate containment, segregation, cleaning of work surfaces, cleaning of utensils and cleaning of personnel to prevent cross-contamination.
- FDCA 501(a)(2)(A)
Non-microbial contamination, production area
Non-microbial contamination was observed in your production area.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance3 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
ISO 5 inside non-classified room
OBSERAVTfON 1 The ISO5 classified area is located within a non-classified room. Specifically, the ISO 5 classified (b)(4) located within a non-classified room. In addition, the ISO 5 classified (b)(4) is where sterile compounding move in and out of the unclassified room. This is a Repeat Observation from previous inspection in
- Observation 2
Non-pharmaceutical components used
OBSERAVTION 2 Non-Pharmaceutical grade components are used in the formulation. Specifically, non-pharmaceutical grade components [(5)] were observed on the shelf with the firm's inventory barcode on the bottle. These components were used in the formulation of non-sterile veterinary drug products: The following 1-prescription for veterinary drug was prepared (b)(4) Exp Date: 11/7/2019 Cyclosporine 2% Ophthalmic Solution in Corn Oil (VET) The following 12-prescriptions for veterinary drugs was Exp Date: 02/02/2018 Atenolol Oil Suspension (Chicken Flavor) (Olive Oil) [additional dated atenolol prescription entries appear in the record]
Show observation 3
- Observation 3
Inadequate cleaning and environmental controls
OBS ERVATION 3 The use of sporicidal agents in the cleanroom and/or ISO 5 area is inadequate or infrequent. a). The firm uses a re-sealable pouch of pre-wetted (b)(4) sterile wipes for cleaning of surfaces inside the ISO 5 classified (b)(4) which on 04/01/19, we observed. There is no assurance that the sterile wipes remain sterile if the pouch is reused, and an expiration date after opening has not been established. A re-sealable pouch of pre-wetted wipes was observed in the ISO 5 classified (b)(4) on 04/01/19, but there was no production occurring at the time. b). On 04/01/19, we observed brown spots forming on the IV bags. According to the pharmacist these brown spots are due to the cleaning product corroding over time. This ISO 5 classified (b)(4) is used for aseptic filling. c). Adequate smoke studies under dynamic conditions have not been performed to demonstrate unidirectional airflow in the ISO 5 area. On 04/01/19, it was observed that (b)(4) and [(5)(4)] were stored inside the ISO 5 classified area. Items are stored in the ISO 5 classified area and not removed because they are needed for operations. The ISO 5 classified air pressure and report provided, dated 12/13/18, do not contain these items within the report.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Protection from external factors
Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Regulations FDA cited here
The 5 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.94Drug product containers and closures1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.166Stability testing1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012223534 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012223534. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.