Skip to content

OneSource Specialty Pharma Limited

Beta Lactam Division, Doresanipalya, 152/6 & 154/16, Bannerghatta Road, Bengaluru, India

FEI 3005652193DUNS 650391548

Company: ONESOURCE SPECIALTY PHARMA LIMITED · Linked by exact D-U-N-S match (867530307) in FDA registration data

FDA has 3 inspections on file for OneSource Specialty Pharma Limited in Bengaluru, India (FEI 3005652193), from 2011 to 2019. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Nov 22, 2024 that FDAgent has not matched to an inspection on the Data Dashboard.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published one citation from this inspection, under 21 CFR Part 211, the manufacturing rules for finished drugs. It is listed below. Three FOIA requests asked FDA for the 483 from a later inspection, ending Nov 22, 2024, that FDA's Data Dashboard doesn't list yet.

The most recent OAI inspection ended on Sep 1, 2015. No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis and sterilization, through Dec 31, 2027. Its registrant, ONESOURCE SPECIALTY PHARMA LIMITED (D-U-N-S 867530307), has registered 2 other sites.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2011–2019
1 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
1 of 3
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Requested under FOIA
3 requests, latest Aug 4, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Aug 4, 2026. Each one asked for a Form 483.

  • Inspection ending Nov 22, 2024

    3 requests. Not listed in FDA’s Data Dashboard yet. FDA has posted its Form 483.

    1. Aug 4, 2026FDA-FOIA-2026-7498Form 483· 1 of 2 sitesWithdrawn
    2. Jun 9, 2026FDA-FOIA-2026-5660Form 483Records released
    3. Apr 30, 2026FDA-FOIA-2026-4273Form 483· 1 of 2 sitesClosed, no reply from requester

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 1 section of 21 CFR in FDA’s published citations for 1 of this facility’s 3 inspections.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis, sterilization
Registration runs through
Dec 31, 2027
Registrant
ONESOURCE SPECIALTY PHARMA LIMITEDD-U-N-S 867530307

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names ONESOURCE SPECIALTY PHARMA LIMITED (D-U-N-S 867530307) as the registrant for this site and the 2 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3005652193 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3005652193. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.