FDA has 8 inspections on file for Alembic Pharmaceuticals Limited in Panchmahal, India (FEI 3004956904), from 2010 to 2024. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant, Alembic Pharmaceuticals Limited (D-U-N-S 650574663), has registered 6 other sites.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
8, 2010–2024
0 OAI · 5 VAI · 3 NAI
Inspections with 483 observations shown
2 of 8
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
2 requests, latest Aug 1, 2022
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    2. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    3. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function and written procedures required by current good manufacturing practice regulations.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Change control not followed for packaging

      The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, For blister packaging machines, the change to include a piece of PO prepared on-site into the the pill and capsule [illegible] and [illegible], to prevent vibration and pill ejection from the [illegible], was not done in accordance with the established change control procedure, to include review, evaluation, and approval by quality assurance. On 22 March 2016, the packaging of [illegible] mg tablet (batch [illegible]), [illegible] mg capsules (batch [illegible]), and [illegible] mg capsules (batch [illegible]) was observed for different packaging lines. On packaging machine [illegible], capsules of [illegible] mg were observed vibrating in the [illegible] and the [illegible], with several capsules being slowly forced upward and falling onto the machine (Photo Taken). Blister packaging lines were in operation, but the vibration was mitigated using a piece of [illegible] placed in the [illegible] to mitigate vibration. While the equipment was designed to include a piece of [illegible] to dampen vibrations in the [illegible] described, it is unclear whether the new material is of similar design and quality to ensure that it does not lead to contamination of the packaged material with foreign material. Moreover, the change from the manufacturer's supplied component, to that which was cut and prepared on-site, was not done per the change control procedure, and was not evaluated by quality assurance for its potential impact on product quality.

    2. Observation 2

      Records not documented contemporaneously

      Written production and process control procedures are not documented at the time of performance. Specifically, During the inspection of blister packaging, in Blister Pack room [illegible], 9 mg capsules batch [illegible] was in the process of set up. It was observed on the batch packaging record that the operator had completed the Challenge Test by initialing the "Done by" column. This was verified with the "Checked by" column being initialed and dated. However, it was observed on the blister pack line the Challenge test was still in progress and was stated as such by the operator. Your firm is not documenting records contemporaneously as activities are completed.

    Show observations 3 to 4
    1. Observation 3

      Inadequate microbiological procedures and monitoring

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written and followed. For example, 1) On 22 March 2016, for plates under incubation, air bubbles were observed between the [illegible] and [illegible] used to perform filtration and microbiological enumeration of [illegible] samples; the test procedure, APL/RT0122, for testing is inadequate in that it does not contain sufficient detail to ensure the absence of air bubbles between the [illegible] and [illegible] prior to incubation. [illegible] is used during the production of non-sterile drugs and for cleaning of manufacturing equipment. There is no data to support the accuracy and sensitivity of this test method when air bubbles are present between the filtration [illegible] and the [illegible] during incubation. 2) The written procedure for environmental monitoring and swab sampling, ALP/QC/SOP098, fails to include the use of [illegible] for the total combined yeast and mold test, which is specified for cleaning validation studies performed for non-dedicated drug manufacturing equipment. 3) On 23 March 2016, a leak was observed from a pipe connecting the [illegible] liter storage tank for distribution and use for production and cleaning operations. The leak was identified as originating from the [illegible] clamp connecting the use-point distribution pipe to the [illegible] tank. There were no controls in place to prevent the potential ingress of objectionable microorganisms into the tank from this leak if [illegible] pressure changes were to occur, and microbiological control systems such as [illegible] are all upstream of this connection. [illegible] from the [illegible] liter tank is distributed through the continuous loop, and is used during the production of non-sterile drugs and for cleaning of manufacturing equipment.

    2. Observation 4

      Insufficient deviation investigations and controls

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, 1) Deviation Investigation #ALP/QA/DC6020 failed to address other drug products that may have been affected by the [illegible] breach coming from the [illegible] and entering the [illegible] (PD/09/[illegible] 02) through the duct pipe. [illegible] tablets [illegible] mg trial batch [illegible] was being [illegible] at the time. The gasket of the line was found damaged and was leaking from the service area, which is the floor [illegible] the [illegible] area. The [illegible] was traveling down the duct work into the [illegible]. Your firm did not assess batches prior to the breach to assure there was no product impact. 2) Deviation Investigation #ALP/QA/DC5175 reported metal detection in tablets [illegible] mg batch [illegible] (Lot rejected). The probable root cause was attributed to a damaged screw on the compression machine which was mishandled with incorrect tools to cause abrasions on the screw. Your firm failed to document re-training on disassembly procedures for the operators identified as a preventative action measure to prevent or mitigate future re-occurrence of the deviation. 3) Tablet and capsule filled bottles that are initially rejected at the checkweigher after filling, labeling, sealing, and capping are re-passed through the checkweigher without investigation into the cause of the initial rejection. If the rejected bottles pass the second pass-through, they are accepted. On 21 March 2016, a bottling operation was observed on the equipment (PD/67/704) in room [illegible] wherein an operator removed a bottle that had been rejected from the [illegible] checkweigher and re-passed it through the checkweigher without investigating the cause of the initial rejection. The procedure describing rejected bottle handling, ALP/PR/SOP243, does not include instructions for investigations into rejected bottles failing at the checkweigher. Since 20 February 2015, there have been 20 market quality complaints regarding bottles which were missing pills or tablets.

  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Aug 1, 2022. Each one asked for a Form 483.

  • Inspection ending Mar 13, 2020VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Aug 1, 2022FDA-FOIA-2022-5539Form 483Closed
  • Inspection date not given

    1 request.

    1. Nov 1, 2018FDA-FOIA-2018-8906Form 483Open

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 3 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 8 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2027
Registrant
Alembic Pharmaceuticals LimitedD-U-N-S 650574663

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Alembic Pharmaceuticals Limited (D-U-N-S 650574663) as the registrant for this site and the 6 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Other FEIs recorded as Alembic Pharmaceuticals Limited

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3004956904 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3004956904. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.