Alembic Pharmaceuticals Limited (Units I and II)

API Division, Village Panelav, P.O. Tajpura, Near Baska, Taluka Halol, Panchmahal, India

FEI 3003821360DUNS 650574705

Company: Alembic Pharmaceuticals Limited · Linked by exact D-U-N-S match (650574663) in FDA registration data

FDA has 8 inspections on file for Alembic Pharmaceuticals Limited (Units I and II) in Panchmahal, India (FEI 3003821360), from 2011 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant, Alembic Pharmaceuticals Limited (D-U-N-S 650574663), has registered 6 other sites.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
8, 2011–2025
0 OAI · 4 VAI · 4 NAI
Inspections with 483 observations shown
1 of 8
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Untimely/inadequate lab investigations

      [Laboratory investigations were not conducted timely based on an identifiable trend or thoroughly to determine the root cause. Specifically, A. An investigation into (b)(4) API (DMF: (b)(4)), stability batch number (b)(4) for the Related Compound was not performed until the impurity was OOS at the 12M timeframe even though the impurity was approximately doubling through the first 6 months and borderline OOS. The OOT procedure, C/QA/SOP/0187, Titled: "Handling of Out of Trend (OOT) Test Results", Effective date: 28-Nov-2024, Annexure X (Trend Analysis for Stability Testing) only requires an OOT investigation if there is a difference in value (b)(4) between stability testing points and does not consider proactively investigating an identifiable trend. Table 1 Batch — Stability Time point [illegible table entries] B. (b)(4) API (DMF: (b)(4)), batch number (b)(4) failed to meet specification limit for Related Compound impurity at 12 month, 18 month and 36 month long term (25°C ±2°C/60%RH ±5%RH) stability time points. The following OOS investigations were performed: OOS No.: OOS/A1/22/0053, Reported date: 11-May-2022, Stability time point: 12M, Result: [illegible]; NMT [illegible] OOS No.: OOS/A1/22/0150, Reported date: 10-Nov-2022, Stability time point: 18M, Result: [illegible]; NMT [illegible] OOS No.: OOS/A1/24/0054, Reported date: 13-May-2024, Stability time point: 36M, Result: [illegible]; NMT [illegible] These OOS investigations concluded that the root cause was based on improper stability sample (b)(4) packing i.e. not (b)(4) with (b)(4) after (b)(4) sample (b)(4) prior to packing leading to oxidative degradation of the stability samples. However, the consistent upward trend of Related Compound impurity from Initial to 9 month stability time points (Table 1) confirmed quality issues with (b)(4) API, batch number (b)(4). In addition, your laboratory investigation checklist (Phase-I (b)) reported no issues with sample integrity and its storage and handling. Re-measurement (re-injection and re-vial) results confirmed the original (OOS) test result during each of these investigations. However, your firm performed retest analyses in triplicate using additional (b)(4) (new sample) which showed passing test results at 12 month and 18 month time points. Your firm provided no justification for differences in the test results of original and retest analyses considering the stability samples were packaged in (b)(4) at the same time following the same practices of not (b)(4) each (b)(4) with (b)(4) by the same QA Executive. Further, your firm provided no justification for not conducting side-by-side comparative analyses on the same sample set sequence to demonstrate that slight variations in chromatographic conditions, diluent, mobile phase, etc. may not have led to variation in the test results.]

    2. Observation 2

      Inadequate stability test validation

      [Laboratory control does not include establishment of scientifically sound and appropriate test procedures and specifications designed to assure quality of drug substances. Specifically, Analytical test procedures used to perform stability testing on APIs for the US market are not adequately validated as stability indicating. For several products there is incomplete data on degradant products and pathways as the Related Substances by HPLC and Assay by HPLC test methods did not meet the validation protocol degradation acceptance limits of 10% for at least (b)(4) conditions. For many of these products the degradation level achieved was 0%. Some examples include: Sr. DMF Acid Base Thermal Photo i. [illegible table entries and examples truncated in the document]]

    Show observations 3 to 4
    1. Observation 3

      Equipment not properly cleaned/maintained

      [Equipment is not cleaned and maintained to prevent contamination that would alter the safety, identity, strength, quality and purity of the drug product. Specifically, On 26-May-2025, I observed non-dedicated production equipment used to manufacture US products in API Unit I plant in a state of disrepair, and it contained residual powdery materials while in the clean status. For example, 1. (b)(4) ID: 013 contained a very thin layer of white powdery residues in some sections post filter in the direction of high velocity air (b)(4) cfm towards [illegible] bowl while this equipment was tagged in "Ready for use" status upon product changeover cleaning post manufacturing of (b)(4) API USP, Batch Number (b)(4). There is no additional filter post I filter to prevent residual powder materials from getting blown towards the [illegible] bowl and contaminating the product. This equipment was tagged in "Ready for use" status upon product changeover cleaning post manufacturing of (b)(4) API USP, Batch Number (b)(4) when these issues were observed. These issues were identified to management at the initiation of this inspection on 26-May-2025 but the equipment continued to be used. 2. (b)(4) ID 047 was observed encrusted in parts with white to off-white powdery materials on the side walls of (b)(4) along with black color (b)(4) that was missing, peeled-off, and loosely hanging on many areas of this equipment that comes directly and indirectly in contact with the product under manufacturing. Additionally, there were dent marks, rough surfaces, and corrosion formation in some areas which may interfere with cleaning of (b)(4) 047. This equipment was tagged in "Ready for use" status upon product changeover cleaning when these issues were observed. Further, this equipment underwent (b)(4) preventative maintenance on 06-May-2025 i.e. about 20 days prior to the start of this inspection; however, the severity of damage to (b)(4) was underreported as a minor issue and there was no mention of issues relating to dent marks, corrosion, and rough surfaces in the preventative maintenance report. 3. (b)(4) ID: 012 was observed encrusted with and color residues in product contact areas. Additionally, it had numerous dent and scratch marks through the product hold areas which may interfere with equipment cleaning. This equipment was tagged in "Ready for use" status upon product changeover cleaning post (b)(4) API USP, Batch Number (b)(4) manufacturing when these issues were observed.]

    2. Observation 4

      Quality Unit lacks document oversight

      [Lack of Quality Unit oversight on document control and review. Specifically, your Quality Unit lacked adequate oversight on employees' practices of documenting GMP activities on uncontrolled papers. For example, On 26-May-2025, I observed torn pieces of uncontrolled papers along with a few intact pieces containing handwritten information in black color indelible ink relating to equipment cleaning, maintenance, and QC testing activities. According to your procedure C/QA/SOP/0018, Titled: "Good Documentation Practices", Effective date: 26-Apr-2025, section 4.1.3 black color indelible ink is used for documentation of GMP activities. These papers were found disposed inside the main scrapyard of your API Unit facility. The evaluation of one of the torn pieces revealed that your operator communicated issues relating to heavy leakage through (b)(4) valve of (b)(4) 150 while this equipment was in use at intermediate stage for (b)(4) batch number (b)(4). There was no incident logged, no impact assessment done, and there was no mention of this issue anywhere in the batch manufacturing record and (b)(4) usage logbook.]

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2027
Registrant
Alembic Pharmaceuticals LimitedD-U-N-S 650574663

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Alembic Pharmaceuticals Limited (D-U-N-S 650574663) as the registrant for this site and the 6 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3003821360 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3003821360. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.