Skip to content

Takeda Pharmaceutical Company Limited

Takeda 4720, Mitsui, Hikari, Japan

FEI 3004664162DUNS 695132431

Company: TAKEDA PHARMACEUTICAL COMPANY LIMITED · Linked by exact D-U-N-S match (690538228) in FDA registration data

FDA has 9 inspections on file for Takeda Pharmaceutical Company Limited in Hikari, Japan (FEI 3004664162), from 2010 to 2023. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below. One of the eight FOIA requests for this site has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Nov 26, 2019. FDA issued a warning letter on (CDER). 1 import refusal is filed under this FEI, on . No court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing and analysis, through Dec 31, 2026. Its registrant, TAKEDA PHARMACEUTICAL COMPANY LIMITED (D-U-N-S 690538228), has registered 3 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
9, 2010–2023
1 OAI · 7 VAI · 1 NAI
Inspections with 483 observations shown
2 of 9
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
8 requests, latest Jun 17, 2025
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      No investigation records for components

      OBSERVATION 1 Written records are not made of investigations of any of its components to meet specifications. Specifically, A. You have not initiated a comprehensive [illegible] complaints reported on your [illegible]. B. Without initiating an investigation into the root cause of drug/device defect complaints, you have [illegible] these complaints which have been reported on a lot of [illegible] and another lot for device component issues.

    2. Observation 2

      Failure to review unexplained discrepancies

      OBSERVATION 2 There is a failure to thoroughly review any unexplained discrepancy and/or the failure of a batch or any of its components to meet any of its specifications. Specifically, A. Your SOP no. 225372 "Visual Inspection" describes your visual inspection process which is followed by your AQL [illegible]. Your Quality Unit does not initiate or consider additional evaluations of your sterile injectable product when action limits are reached. Negative quality signals are not acted upon with additional visual inspections and/or tightened AQL evaluations until the product is sent through a normal AQL evaluation and defects exceeding that [illegible]. B. In your Defect Library dirt is considered [illegible]. In addition, if particulates are experienced on the outside of the drug product they are not given a classification of intrinsic or extrinsic.

    Show observations 3 to 4
    1. Observation 3

      Inadequate environmental monitoring system

      OBSERVATION 3 Aseptic processing areas are deficient regarding the system for monitoring environmental [illegible]. Specifically, During my review of "EM Risk Assessment and EM [illegible]" presented to me on 11/06/2023, the firm [illegible] particle counter [illegible] is approximately [illegible] during filling operations.

    2. Observation 4

      Endotoxin and lab testing deficiencies

      OBSERVATION 4 Each batch of drug product required to be free of objectionable microorganisms [illegible] appropriate laboratory testing. Specifically, On 10/31/2023 a microbiologist was observed performing Endotoxin Testing on material manufactured on 10/28/2023 using the harmonized Kinetic Photometric assay. The firm's test procedure [illegible] requires the measurement of pH value of the sample and [illegible] sample with LAL reagents after the test [illegible].

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include maintenance and cleaning schedules, description in sufficient detail of methods, equipment and materials used, description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance and instructions for protection of clean equipment from contamination prior to use.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    3. Extent of discrepancy, failure investigations

      Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    5. Failing drug products not rejected

      Drug products failing to meet established specifications are not rejected.

    Show 2 more citations
    1. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process.

    2. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions that would alter the safety, identity, strength, quality or purity of the drug product.

  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  10. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Eight requests to FDA under the Freedom of Information Act named this site, most recently on Jun 17, 2025.

  • Inspection ending Nov 6, 2023VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Nov 5, 2024FDA-FOIA-2024-9824Form 483· 1 of 2 sitesClosed
  • Inspection ending Jul 19, 2021VAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 28, 2025. FDAgent holds no copy that FDA posted.

    1. Jun 17, 2025FDA-FOIA-2025-7806Form 483· 1 of 3 sitesRecords released
    2. May 23, 2025FDA-FOIA-2025-4671Form 483· 1 of 3 sitesWithdrawn
  • Inspection ending Nov 26, 2019OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Mar 9, 2021FDA-FOIA-2021-1599EIRClosed
  • Inspection date not given

    4 requests. None of FDA’s log entries for these requests say records were released.

    1. Jan 2, 2024FDA-FOIA-2024-11Form 483Closed
    2. Nov 1, 2023FDA-FOIA-2023-9577Form 483Closed
    3. Apr 5, 2022FDA-FOIA-2022-2534EIRClosed
    4. Nov 16, 2021FDA-FOIA-2021-7870Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 5 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 9 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3004664162, one row per refused product line.

1 refusal on 2025-06-03 · charged NO ENGLISH on 1, UNAPPROVED on 1 · no FDA sample analysis

FDA firm profile
  • 2025-06-03

    ANTI-INFLAMMATORY N.E.C.62GDL99

    NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-7622704-2/12/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, API manufacturing, packing, analysis
Registration runs through
Dec 31, 2026
Registrant
TAKEDA PHARMACEUTICAL COMPANY LIMITEDD-U-N-S 690538228

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names TAKEDA PHARMACEUTICAL COMPANY LIMITED (D-U-N-S 690538228) as the registrant for this site and the 3 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Other FEIs recorded as Takeda Pharmaceutical Company Limited

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3004664162 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3004664162. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.