Skip to content

Coast Quality Pharmacy, LLC dba Anazao Health

5710 Hoover Blvd, Tampa, Florida, United States

FEI 3004483463

FDA has 2 inspections on file for Coast Quality Pharmacy, LLC dba Anazao Health in Tampa, Florida (FEI 3004483463), from 2018 to 2019. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published 5 citations from this inspection. They are listed below.

The most recent OAI inspection ended on May 7, 2018. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Three regulations were cited at more than one inspection: 21 CFR 211.113(b), 21 CFR 211.166(a)(3) and FDCA 501(a)(2)(A).

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2018–2019
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
3 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
4 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Valid stability test methods

      The written stability program for drug products does not include reliable, meaningful and specific test methods.

    2. FDCA 501(a)(2)(A)

      Actionable microbial contamination, adjacent area

      You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in an area adjacent to the ISO 5 classified aseptic processing area during aseptic production.

    3. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process.

    4. FDCA 501(a)(2)(A)

      Use of non-pharmaceutical grade components

      You used a non-pharmaceutical grade component in the formulation of a drug product.

    5. FDCA 501(a)(2)(A)

      Disinfecting and cleaning agents, ISO 5 area

      Disinfecting agents and used in the ISO 5 classified aseptic processing areas were not sterile.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Improper gowning, contamination

      Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated.

    2. Valid stability test methods

      The written stability program for drug products does not include reliable, meaningful and specific test methods.

    3. FDCA 501(a)(2)(A)

      Disinfecting materials, aseptic processing area

      Equipment was and Materials or supplies were not disinfected prior to entering the aseptic processing areas.

    4. FDCA 501(a)(2)(A)

      Dust-collecting overhangs, surrounding area of ISO 5

      The ISO 5 classified aseptic processing areas and segregated production areas surrounding the ISO 5 classified aseptic processing area contained dust-collecting overhangs without adequate and frequent cleaning.

    5. FDCA 501(a)(2)(A)

      Disruption of airflow from personnel movement

      Personnel moved rapidly in the vicinity of open sterile units and instruments, which disrupted the airflow and increased the risk of bringing lesser quality air into the ISO 5 classified aseptic processing area.

    Show 8 more citations
    1. Extent of discrepancy, failure investigations

      Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product.

    2. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval and rejection of components, drug product containers and closures.

    3. FDCA 501(a)(2)(A)

      Use of non-pharmaceutical grade components

      You used a non-pharmaceutical grade component in the formulation of a drug product.

    4. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    5. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    6. Air Supply

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

    7. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    8. FDCA 501(a)(2)(A)

      Actionable microbial contamination, ISO 5 area

      You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production.

  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF

Regulations FDA cited here

The 5 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004483463 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004483463. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.