FDA has 5 inspections on file for Ascend Laboratories, LLC in Bedminster, New Jersey (FEI 3004459274), from 2011 to 2021. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 3 citations from this inspection, all under 21 CFR Part 314, the rules for new drug applications. They are listed below. One FOIA request has asked FDA for this inspection's 483.
FDA's compliance record also lists 2 other actions under this FEI, the latest Injunction, . 1 import refusal is filed under this FEI, on . No warning letter is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.22(d).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2011–2021
- 0 OAI · 3 VAI · 2 NAI
- Inspections with 483 observations shown
- 3 of 5
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest Oct 2, 2023
- Warning letters
- None on file
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch Monitoring3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Late submission of annual safety reports
Not all annual periodic adverse drug experience reports have been submitted within 60 days of the anniversary date of the approval of the application.
Failure to develop written procedures
Written procedures have not been developed for the reporting to FDA of post marketing adverse drug experiences.
Timely submission
An annual report was not submitted within 60 days of the anniversary date of U.S. approval of the application to the FDA division responsible for reviewing the application.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- NAINo objectionable conditions that need follow-upDrugs · Unapproved and Misbranded DrugsNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.
Recall facilitation
A system by which the distribution of each lot of drug product can be readily determined to facilitate its recall if necessary, has not been established.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Oct 2, 2023. It asked for a Form 483.
Inspection ending Nov 10, 2021VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Oct 2, 2023FDA-FOIA-2023-8386Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 3
- 21 CFR 211.25Personnel qualifications1 of 3
- 21 CFR 211.150Distribution procedures1 of 3
- 21 CFR 211.192Production record review1 of 3
- 21 CFR 211.198Complaint files1 of 3
- 21 CFR 314.80Postmarketing reporting of adverse drug experiences1 of 3
- 21 CFR 314.81Other postmarketing reports1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- InjunctionCDER · DrugsFDA record
- SeizureCDER · DrugsFDA record
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3004459274, one row per refused product line.
1 refusal on 2020-07-08 · charged UNAPPROVED on 1 · no FDA sample analysis
FDA firm profile- 2020-07-08
ATORVASTATIN CALCIUM (ANTI-CHOLESTEREMIC)61JCA08
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-7512285-2/31/1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004459274 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004459274. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.