Ioannis Lougaris VA Medical Center Laboratory Service (113) Blood Bank
975 Kirman Ave # 113, Reno, Nevada, United States
FEI 2972635
FDA has 7 inspections on file for Ioannis Lougaris VA Medical Center Laboratory Service (113) Blood Bank in Reno, Nevada (FEI 2972635), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 5 citations from this inspection, all under 21 CFR Part 606, the manufacturing rules for blood and blood components. They are listed below. Three FOIA requests have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 606.100(b) and 21 CFR 606.160(b).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 7, 2009–2025
- 0 OAI · 2 VAI · 5 NAI
- Inspections with 483 observations shown
- 2 of 7
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 3 requests, latest May 19, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Biological product deviation report
Failure to submit a biological product deviation report.
Required records
Failure to maintain processing, compatibility testing and general records.
Thorough investigations
Failure to make a record of the conclusions and follow-up of an unexplained discrepancy and a failure of a lot or unit to meet any of its specifications.
SOPs for investigations, records
Written standard operating procedures for all steps in the investigation of product deviations under the regulations were not established.
Adverse Reaction - Investigations
A thorough investigation of each reported adverse reaction was not made.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene Therapies4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Required records
Failure to maintain quality control records.
Equipment observed, standardized, calibrated
Equipment used in the processing of blood and blood components is not standardized and calibrated on a regularly scheduled basis as prescribed in the SOP Manual to assure that it performs in the manner for which it was designed.
Person performing, test results, interpretation
Records fail to identify the person performing the work and show test results so as to provide a complete history of the work performed.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the compatibility testing of blood and blood components for are not always followed.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on May 19, 2026. Each one asked for a Form 483.
Inspection ending Feb 28, 2025VAI
3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on May 19, 2026. FDAgent holds no copy that FDA posted.
- May 19, 2026FDA-FOIA-2026-5094Form 483· 1 of 5 sitesClosed
- Feb 16, 2026FDA-FOIA-2026-1594Form 483Records released
- Apr 29, 2025FDA-FOIA-2025-3784Form 483· 1 of 5 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 5 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 606.100Standard operating procedures2 of 2
- 21 CFR 606.160Records2 of 2
- 21 CFR 606.60Equipment1 of 2
- 21 CFR 606.170Adverse reaction file1 of 2
- 21 CFR 606.171Reporting of product deviations by licensed manufacturers, unlicensed registered blood establishments, and transfusion services1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 2972635 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 2972635. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.