Skip to content

Cryo-Cell International, Inc

700 Brooker Creek Blvd Ste 1800, Oldsmar, Florida, United States

FEI 2246948

FDA has 7 inspections on file for Cryo-Cell International, Inc in Oldsmar, Florida (FEI 2246948), from 2009 to 2024. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
7, 2009–2024
0 OAI · 3 VAI · 4 NAI
Inspections with 483 observations shown
2 of 7
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
1 request, latest May 13, 2024
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  2. NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic ProductsNone
  3. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Postmarket Assurance: Devices2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Nonconforming product, Lack of or inadequate procedures

      Procedures have not been adequately established to control product that does not conform to specified requirements.

    2. Lack of System for Determining MDR Events

      The written MDR procedure does not include an internal system which provides for a standardized review process/procedure for determining when an event meets the criteria for reporting.

  5. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Validation & approval--established procedures

      Processes with results which could not be fully verified by inspection and tests, were not validated and approved according to established procedures.

    2. Documentation--determination, by whom, date

      Documentation of the donor-eligibility determination, the responsible person who made the donor-eligibility determination, and the date of the donor-eligibility determination was not maintained.

    3. SOP for release; reactive for CMV

      A standard operating procedure for the release of HCT/Ps from donors that test reactive for cytomegalovirus (CMV) was not established and maintained.

    4. Testing, screening, donor eligibility procedures

      Procedures for all steps performed in the screening of donor eligibility of HCT/Ps were not established and maintained.

    5. Risk factors, clinical evidence

      Donors were not screened by a review of relevant medical records for clinical evidence of communicable disease agents and diseases.

  7. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene TherapiesCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on May 13, 2024. It asked for a Form 483.

  • Inspection ending Sep 19, 2017VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. May 13, 2024FDA-FOIA-2024-4309Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 7 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 7 inspections, with how many of them cited each.

  • 21 CFR 803.17What are the requirements for developing, maintaining, and implementing written MDR procedures that apply to me?1 of 2
  • 21 CFR 820.90Nonconforming product1 of 2
  • 21 CFR 1271.47What procedures must I establish and maintain?1 of 2
  • 21 CFR 1271.55What records must accompany an HCT/P after the donor-eligibility determination is complete; and what records must I retain?1 of 2
  • 21 CFR 1271.75How do I screen a donor?1 of 2
  • 21 CFR 1271.85What donor testing is required for different types of cells and tissues?1 of 2
  • 21 CFR 1271.230Process validation1 of 2

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 2246948 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 2246948. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.