Versiti Wisconsin, Inc
638 N 18th St, Milwaukee, Wisconsin, United States
FEI 2171378
FDA has 15 inspections on file for Versiti Wisconsin, Inc in Milwaukee, Wisconsin (FEI 2171378), from 2009 to 2026. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 15, 2009–2026
- 0 OAI · 4 VAI · 11 NAI
- Inspections with 483 observations shown
- 2 of 15
- 1 with citations published, text not held
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
15 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
One or more approved screening tests
Blood and blood components intended for transfusion or for use in manufacturing a product were not tested for evidence of infection due to relevant transfusion-transmitted infections in accordance with the manufacturer's instructions.
Additional Medical Assessment Factors
Medical history assessment failed to include factors that make the donor ineligible to donate when donating could adversely affect the health of the donor or the safety, purity, or potency of the blood or blood component could be affected adversely by travel to, or residence in, an area endemic for a transfusion-transmitted infection.
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene TherapiesCitations published; text not held
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Maintain and clean equipment
Failure to maintain equipment used in the collection of blood and blood products so as to facilitate cleaning and maintenance.
Closed system
The blood is not collected by aseptic methods in a sterile system.
Biological product deviation report
Failure to submit a biological product deviation report.
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
Regulations FDA cited here
The 5 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 15 inspections, with how many of them cited each.
- 21 CFR 606.60Equipment1 of 2
- 21 CFR 606.171Reporting of product deviations by licensed manufacturers, unlicensed registered blood establishments, and transfusion services1 of 2
- 21 CFR 610.40Test requirements1 of 2
- 21 CFR 630.10General donor eligibility requirements1 of 2
- 21 CFR 640.4Collection of the blood1 of 2
Other FEIs recorded as Versiti Wisconsin, Inc
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Versiti Wisconsin, IncFEI 2177744Mount Pleasant, Wisconsin, United States
Last inspected 2025-06-12NAI
Versiti Wisconsin, IncFEI 2177747Waukesha, Wisconsin, United States
Last inspected 2024-04-22NAI
Versiti Wisconsin, IncFEI 1000116289Wauwatosa, Wisconsin, United States
Last inspected 2024-04-19NAI
Versiti Wisconsin, IncFEI 3002860769Fitchburg, Wisconsin, United States
Last inspected 2018-05-31NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 2171378 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 2171378. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.