Granite City Illinois Hospital Corporation, LLC
2100 Madison Ave, Granite City, Illinois, United States
FEI 1472015
FDA has 4 inspections on file for Granite City Illinois Hospital Corporation, LLC in Granite City, Illinois (FEI 1472015), from 2010 to 2017. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 606.160(a)(1).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 4, 2010–2017
- 0 OAI · 2 VAI · 2 NAI
- Inspections with 483 observations shown
- 2 of 4
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the storage of blood and blood components for homologous transfusion are not always maintained and followed.
Biological product deviation report
Failure to submit a biological product deviation report.
Concurrent documentation
Records are not concurrently maintained with the performance of each significant step in the storage of each unit of blood and blood components so that all steps can be clearly traced.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Concurrent documentation
Records are not concurrently maintained with the performance of each significant step in the collection and processing of each unit of blood and blood components so that all steps can be clearly traced.
Required records
Failure to maintain donor, processing, storage and distribution, quality control, and general records.
Thorough investigations
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy and a failure of a lot or unit to meet any of its specifications.
Following manufacturer's instructions
Failure to use supplies and reagents in a manner consistent with instructions provided by the manufacturer.
Legibility and indelibility
Records are illegible.
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
Regulations FDA cited here
The 4 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 606.100Standard operating procedures2 of 2
- 21 CFR 606.160Records2 of 2
- 21 CFR 606.65Supplies and reagents1 of 2
- 21 CFR 606.171Reporting of product deviations by licensed manufacturers, unlicensed registered blood establishments, and transfusion services1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1472015 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1472015. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.