Skip to content

Richmond VA Medical Center

Richmond, Virginia, United States

FEI 1174302

FDA has 12 inspections on file for Richmond VA Medical Center in Richmond, Virginia (FEI 1174302), from 2009 to 2026. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
12, 2009–2026
0 OAI · 5 VAI · 6 NAI
Inspections with 483 observations shown
3 of 12
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

12 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Hands blocking first air

      OBSERVATION 1 Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted. Specifically, On 05/05/2026, a compounding technician was observed preparing the following prescription in Buffer Room 1H-110A: RX# (b)(5).(b)(7)(C) - TPN, 2000 mL IV Bag During the preparation of RX# (b)(5).(b)(7)(C) the following deficiency was observed: While injecting components into the 2000 mL IV bag, the technician's hand placement was observed blocking the bag port and needle. The technician's hands were positioned in a manner that obstructed the unidirectional first air between the HEPA filter face and the critical work surface, thereby compromising the sterility assurance of the critical area.

    2. Observation 2

      Exposed skin in ISO 5

      OBSERVATION 2 Personnel performed aseptic manipulations with exposed hair or skin. Specifically, a. The compounding technician was observed leaning into the ISO 5 Laminar Airflow Workbench (LAFW) with exposed skin around the eyes and forehead while performing aseptic manipulations of RX# (b)(5).(b)(7)(C) - TPN, 2000 mL IV Bag, increasing the risk of contamination to the critical work surface. b. The compounding technician's upper torso was observed physically introduced into the ISO 5 LAFW environment during aseptic manipulations. As gowns are not sterile, the introduction of the technician's torso into the ISO 5 environment represents an independent contamination risk, regardless of the gown's condition. This action resulted in the technician's body blocking and disrupting the unidirectional HEPA-filtered airflow (first air) over the critical work surface, compromising the sterility assurance of the critical area.

    Show observations 3 to 8
    1. Observation 3

      Equipment not disinfected between transitions

      OBSERVATION 3 Lack of disinfection of equipment at each transition from areas of lower quality air to areas of higher quality air. Specifically, On 05/05/2026, a compounding technician was observed preparing the following prescription in Sterile Buffer Room 1H-110A: RX# (b)(5).(b)(7)(C) - TPN, 2000 mL IV bag During TPN compounding, the technician was observed operating a scanner connected to the (b)(4) TPN Compounder Computer while entering multiple times into and out of the ISO 5 LAFW without disinfecting the scanner or gloves each time. Additionally, the technician was observed touching the TPN formulation via the (b)(4) Control Panel (Version (b)(4)) touchscreen on the (b)(4) TPN Compounder Computer touchscreen, which is located outside of the ISO 5 LAFW, then going back into the ISO 5 hood to perform aseptic manipulations without disinfecting their gloves.

    2. Observation 4

      Rapid movement disrupting airflow

      OBSERVATION 4 Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow. Specifically, On 05/05/2026, a compounding technician was observed preparing the following prescription in Buffer Room 1H-110A: RX# (b)(6).(b)(?)(C) - Remicade (Infliximab) 500 mg/0.9% NS, 250 mL IV bag The compounding technician was observed moving quickly within the ISO 5 LAFW workspace during aseptic manipulations, disrupting unidirectional airflow and increasing the risk of introducing lesser-quality air into the ISO 5 critical area.

    3. Observation 5

      Inadequate disinfectant wiping technique

      OBSERVATION 5 Use of a disinfectant in a manner insufficient to achieve adequate levels of disinfection. Specifically, On 5/6/2026 during cleaning operations, cleaning performed within the ISO 5 classified laminar airflow hood (LAFH), cleaning procedures were found to be inadequate in the following respects: a. A compounding technician was observed wiping the interior surfaces of the ISO 5 LAFH without using overlapping wipe passes during the cleaning procedure. The absence of overlapping strokes resulted in visible gaps in surface contact, with some interior surface areas visibly not contacted or wetted by the disinfectant wipe. b. The compounding technician was observed using a back-and-forth scrubbing motion while wiping the interior surfaces of the ISO 5 classified LAFH, rather than the required unidirectional wiping technique, potentially spreading contaminants to previously cleaned areas and negating the effectiveness of the disinfection process.

    4. Observation 6

      Improper sporicidal application

      OBSERVATION 6 Use of a sporicidal agent in the facility's ISO 5 areas was improper. Specifically, The compounding technician was observed performing the [illegible] cleaning of the ISO 5 classified laminar airflow hoods and ISO 7 classified buffer room. The technician [illegible] a [illegible]-wetted sterile wipe treated with sterile (b)(6) (b)(4) (manufactured by (b)(6) (b)(4)) to the (b)(6) (b)(4) workbench and the [illegible] and interior surfaces of the laminar airflow hoods. Following application, all treated surfaces were observed to air-dry within a couple of seconds. This is inconsistent with the sterile (b)(6) (b)(4) manufacturer's (b)(6) (b)(4) specified dwell time of [illegible] for sporicidal effect.

    5. Observation 7

      Light fixture housing gap

      OBSERVATION 7 Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area. Specifically, All (b)(6)(4) light fixture housing in the ISO 5 laminar flow hood (LFH) is not properly seated, creating a gap between the housing and the surrounding surface. This gap constitutes a hard-to-clean area that may harbor particulate matter and microbial contamination, posing a risk to product quality.

    6. Observation 8

      Smoke studies not dynamic

      OBSERVATION 8 Smoke studies were not performed under dynamic conditions. Specifically, The smoke study videos for the pharmacy's (b)(4) laminar airflow workbenches (LAFWs) and (b)(4) biological safety cabinets (BSCs) did not demonstrate manipulations or conditions representative of the dynamic processes used in the compounding of sterile preparations; therefore, the studies were not conducted in a manner that adequately replicates the range, complexity, or pace of actual compounding operations performed at these workstations. As a result, the studies failed to verify unidirectional airflow within the ISO 5 classified area is sufficient to protect critical sites during representative aseptic manipulations. Additionally, the volume and/or density of smoke used during these studies was inadequate to sufficiently visualize airflow patterns and identify potential turbulence or contamination risks within the ISO 5 area.

  2. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  3. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  4. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  8. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Approval and review of procedures

      Written procedures are not reviewed and approved by the quality control unit.

    2. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the distribution of blood and blood components for homologous transfusion are not always followed.

  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.

    2. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    3. No written record of investigation

      Written records are not made of investigations into unexplained discrepancies.

  10. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  11. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  12. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published

Regulations FDA cited here

The 5 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 12 inspections, with how many of them cited each.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1174302 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1174302. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.