Sanofi Winthrop Industrie
180 rue Jean Jaures, Maisons Alfort, France
FEI 1000610805
FDA has 5 inspections on file for Sanofi Winthrop Industrie in Maisons Alfort, France (FEI 1000610805), from 2010 to 2021. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.
1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2010–2021
- 0 OAI · 4 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 5
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Test methods
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit.
Training , Education , Experience overall
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.
Defined areas of adequate size for operations
The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.192Production record review1 of 2
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1000610805, one row per refused product line.
1 refusal on 2026-02-19 · charged UNAPPROVED on 1 · no FDA sample analysis
FDA firm profile- 2026-02-19
ENOXAPARIN SODIUM (ANTI-COAGULANT)61LCK29
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-9378844-4/10002/1
Other FEIs recorded as Sanofi Winthrop Industrie
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Sanofi Winthrop IndustrieFEI 3002808000Vitry-Sur-Seine, France
Last inspected 2024-10-04VAI
Sanofi Winthrop IndustrieFEI 3006287395Val De Reuil, France
Last inspected 2024-01-26VAI
Sanofi Winthrop IndustrieFEI 3014781447Neuville-Sur-Saone, France
Last inspected 2024-01-12NAI
Sanofi Winthrop IndustrieFEI 3002808208Carbon Blanc CEDEX, France
Last inspected 2023-11-22VAI
Sanofi Winthrop IndustrieFEI 3009194033Lyon, France
Last inspected 2023-11-17VAI
Sanofi Winthrop IndustrieFEI 3002972083Marcy-L'Etoile, France
Last inspected 2023-09-29VAI
Sanofi Winthrop IndustrieFEI 1000476619Sisteron, France
Last inspected 2023-09-15VAI
Sanofi Winthrop IndustrieFEI 3003259844Le Trait, France
Last inspected 2023-04-25VAI
Sanofi Winthrop IndustrieFEI 3002808341Aramon, France
Last inspected 2023-03-10VAI
Sanofi Winthrop IndustrieFEI 3003282644Tours, France
Last inspected 2023-01-27VAI
Not every site is listed: these are the most recently inspected sites found under this name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000610805 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000610805. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.