Skip to content

Venture Tech, Inc.

10350 Yellow Pine Ln, Knoxville, Tennessee, United States

FEI 1000112680

FDA has 2 inspections on file for Venture Tech, Inc. in Knoxville, Tennessee (FEI 1000112680), from 2010 to 2016. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
2, 2010–2016
0 OAI · 1 VAI · 1 NAI
Inspections with 483 observations shown
1 of 2
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  2. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices14 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    2. Actual yield, % of theoretical yield

      The batch production and control records do not include a statement of the actual yield and percentage of theoretical yield at appropriate stages of processing for each batch of drug product produced.

    3. Identification of persons involved, each significant step

      Batch production and control records do not include the identification of the persons performing, directly supervising, and checking each significant step in the operation, for each batch of drug product produced.

    4. Accurate reproduction included

      Batch production and control records for each batch of drug product produced do not include an accurate reproduction of the appropriate master production or control record which was checked for accuracy, dated and signed.

    5. Results not used for expiration dates, storage cond.

      Results of stability testing are not used in determining appropriate storage conditions and expiration dates.

    Show 9 more citations
    1. Distinctive ID or code not recorded in batch record

      The batch records do not record the distinctive identification number, code, and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.

    2. Cleaning/maintenance records not kept

      Records are not kept for the maintenance, cleaning, and sanitizing of equipment.

    3. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    4. Following/documenting laboratory controls

      Established specifications, standards, and laboratory control mechanisms are not followed and documented at the time of performance.

    5. In-process samples representative, identified properly

      Samples taken of in-process materials for determination of conformance to specifications are not representative and properly identified.

    6. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are not written or followed.

    7. Approval and review of procedures

      Written procedures are not drafted, reviewed and approved by the appropriate organizational units.

    8. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    9. Strict control not exercised over labeling issued

      Strict control is not exercised over labeling issued for use in drug product labeling operations.

Regulations FDA cited here

The 9 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Show all 9

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1000112680 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1000112680. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.