2026-W14 · 2026-03-30 to 2026-04-05
FDA enforcement, week of 2026-03-30
In 2026-W14 (2026-03-30 to 2026-04-05), FDA posted 2 warning letters from its drug, biologics and device offices, and listed 2 Form 483s in its Electronic Reading Room for the first time. FDA's Enforcement Report added 73 drug and device recalls, 13 of them Class I. FDAgent recorded no new Official Action Indicated (OAI) classifications in FDA's inspection data. FDA published 9 firm entries on its import alert lists, 7 of them on a Red List.
- Warning letters posted
- 2
- Posted 2026-03-31
- Form 483s listed
- 2
- In the reading room
- Recalls
- 73
- 13 Class I · 48 II · 12 III
- New OAI classifications
- 0
- Newly listed by FDA
Ask FDAgent about this week
FDAgent reads the warning letters FDA posted this week and answers in plain English, with links to the letters.
Warning letters
2 letters FDA posted on its warning letters page this week, from its drug, biologics and device offices. Each letter's issue date can be weeks before its posting date. Warning letters last synced Nov 23, 2026, 04:17 UTC.
Microbiological Testing & Consulting, LLC
CGMP/Finished Pharmaceuticals/Adulterated
CDER · issued 2026-03-16 · posted 2026-03-31
CGMP/QSR/Medical Devices/Adulterated
CDRH · issued 2025-11-12 · posted 2026-03-31
An FEI links to its facility page only when the letter names exactly one FEI and FDAgent holds FDA records for it.
Import alert entries
9 firm entries FDA published on its import alert pages this week, dated by each entry's date published: 7 on a Red List, 2 on a Green List. FDA lists firms by name and address; FDAgent links an entry to a facility only when FDA printed the firm's FEI. 1 entry whose name may be a person's rather than a firm's is not listed or counted here; signed-in users can see them in FDAgent. Import alerts last synced Nov 23, 2026, 04:17 UTC.
66-40Red List2 entriesAlert on fda.govShow allDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsAlert on fda.gov
- Published 2026-04-03
Huons Co., Ltd.
KOREA (THE REPUBLIC OF)
- Published 2026-03-31
IDO PHARM
KOREA (THE REPUBLIC OF)
68-19Red List1 entryAlert on fda.govShow allDETENTION WITHOUT PHYSICAL EXAMINATION OF UNAPPROVED FINISHED NEW ANIMAL DRUGSAlert on fda.gov
- Published 2026-03-31
Biopharm Australia Pty. Ltd.
AUSTRALIA
76-01Green List2 entriesAlert on fda.govShow allDetention Without Physical Examination Of Medical Instruments from PakistanAlert on fda.gov
- Published 2026-04-01
Green Life International
PAKISTAN
- Published 2026-03-31
Cotton Craft (PVT) Limited
PAKISTAN
89-17Red List3 entriesAlert on fda.govShow allDetention Without Physical Examination of Medical Devices That Appear to Be Adulterated Because Their Quality Falls Below That Which They Purport or Are Represented to PossessAlert on fda.gov
- Published 2026-04-01
Quality Concept (Pvt) Ltd.
PAKISTAN
- Published 2026-03-31
Glorious Mercantile Corp. Pvt. Ltd.
PAKISTAN
- Published 2026-03-31
GLORIOUS MERCANTILE CORPORATION
PAKISTAN
95-05Red List1 entryAlert on fda.govShow allDetention Without Physical Examination of Electronic Products that Fail to Comply with Performance Standards or to Have Required CertificationAlert on fda.gov
- Published 2026-03-30
Shenzhen Worgo Technology Co, Ltd.
CHINA
Form 483s listed in FDA's Electronic Reading Room
2 Form 483s FDA listed for the first time in its Electronic Reading Room this week, dated by the publish date FDA gives each. FDA sometimes lists a 483 days after that date, so a week can still gain 483s after it ends. FDA posts only some 483s, often months after the inspection. Reading room last synced Nov 23, 2026, 04:33 UTC.
- Listed 2026-04-03
FDA record date 2024-04-18
- Listed 2026-04-03
FDA record date 2025-02-07
Recalls by class
Drug and device recalls in FDA's Enforcement Report dated this week, from openFDA, which FDA last updated Nov 11, 2026.
Class I13 recallsShow all
- Z-1566-2026openFDA record
Erbe USA Inc
Flexible Cryoprobe (OD 1.1mm, L1.15mm) w/ oversheath (OD2.6mm, L817mm) REF: 20402-401 STERILE EO. For surgical use
Reason: Probes may rupture/burst during activation
Device · initiated 2026-02-12 · Enforcement Report 2026-04-01 · Ongoing
- Z-1567-2026openFDA record
Erbe USA Inc
Flexible Cryoprobe (OD 1.7mm, L1.15mm) REF: 20402-410. For surgical use
Reason: Probes may rupture/burst during activation
Device · initiated 2026-02-12 · Enforcement Report 2026-04-01 · Ongoing
- Z-1568-2026openFDA record
Erbe USA Inc
Flexible Cryoprobe (OD 2.4mm, L1.15mm) REF: 20402-411. For surgical use
Reason: Probes may rupture/burst during activation
Device · initiated 2026-02-12 · Enforcement Report 2026-04-01 · Ongoing
- Z-1575-2026openFDA record
Merit Medical Systems, Inc.
CentrosFLO Hemodialysis Catheters, REF: CENFP15K/A, CENFP15K/B, CENFP17K/A, CENFP19K/A, CENFP23K/A, CENFP27K/A, CENFP31K/A, CENFT15K, CENFT15K/D, CENFT17K, CENFT17K/A, CENFT17K/D, CENFT19K, CENFT19K/A, CENFT19K/B, CENFT19K/D, CENFT23K, CENFT23K/A, CENFT23K/B, CENFT23K/D, CENFT27…
Reason: 16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss of vessel for future vascular access.
Device · initiated 2026-02-13 · Enforcement Report 2026-04-01 · Ongoing
- Z-1576-2026openFDA record
Merit Medical Systems, Inc.
ProGuide Chronic Dialysis Catheters, REF: DC01455550/C, DC21452419/C, DC21452419-NE5/C, DC21452823-NE5/C, DC21454035/C, DC21455550/C
Reason: 16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss of vessel for future vascular access.
Device · initiated 2026-02-13 · Enforcement Report 2026-04-01 · Ongoing
- Z-1577-2026openFDA record
Merit Medical Systems, Inc.
16F Dual Valved Splittable Sheath Introducer (bulk, non-sterile), REF: FCL-174-00/B
Reason: 16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss of vessel for future vascular access.
Device · initiated 2026-02-13 · Enforcement Report 2026-04-01 · Ongoing
- Z-1578-2026openFDA record
Merit Medical Systems, Inc.
DuraMax Chronic Hemodialysis Catheter, REF: H787103028015/A, H787103028025/A, H787103028031/A, H787103028035/A, H787103028041/A, H787103028045/A, H787103028051/A, H787103028055/A, H787103028061/A, H787103028075/A, H787103028085/A, H787103028095/A, H787103028165/A, H787103028181/…
Reason: 16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss of vessel for future vascular access.
Device · initiated 2026-02-13 · Enforcement Report 2026-04-01 · Ongoing
- Z-1579-2026openFDA record
Merit Medical Systems, Inc.
BioFlo DuraMax Catheter, REF: H965103028011/A, H965103028021/A, H965103028021/EU, H965103028031/A, H965103028031/EU, H965103028041/A, H965103028041/EU, H965103028051/A, H965103028051/EU, H965103028061/A, H965103028061/EU, H965103028070/A, H965103028070/EU, H965103028080/A, H9651…
Reason: 16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss of vessel for future vascular access.
Device · initiated 2026-02-13 · Enforcement Report 2026-04-01 · Ongoing
- Z-1588-2026openFDA record
Navajo Manufacturing Company
Handy Solutions Neck & Shoulders Heating Pad, Number: 25607, Manufactured by Ninbo Unico Products Co., Ltd
Reason: If heating pad is folded while in use, the power density increases in the folded area causing excessive temperatures, which can also be caused by placing pad under the body, then the high limit device is unable to sense the higher temperature so power is not terminated. May caus…
Device · initiated 2026-02-18 · Enforcement Report 2026-04-01 · Ongoing
- Z-1614-2026openFDA record
Philips Respironics, Inc.
Philips Respironics Trilogy Evo, Software Version 1.05.15.00. Continuous home-use ventilator device.
Reason: Using non-pneumatic nebulizers with Trilogy Evo Platform ventilators may result in a discrepancy between the set tidal volume and the tidal volume received by the patient.
Device · initiated 2026-03-02 · Enforcement Report 2026-04-01 · Ongoing
- Z-1615-2026openFDA record
Philips Respironics, Inc.
Philips Respironics Trilogy Evo O2, Software Version 1.05.15.00. Continuous home-use ventilator device.
Reason: Using non-pneumatic nebulizers with Trilogy Evo Platform ventilators may result in a discrepancy between the set tidal volume and the tidal volume received by the patient.
Device · initiated 2026-03-02 · Enforcement Report 2026-04-01 · Ongoing
- Z-1616-2026openFDA record
Philips Respironics, Inc.
Philips Respironics Trilogy EV300, Software Version 1.05.15.00. Continuous home-use ventilator device.
Reason: Using non-pneumatic nebulizers with Trilogy Evo Platform ventilators may result in a discrepancy between the set tidal volume and the tidal volume received by the patient.
Device · initiated 2026-03-02 · Enforcement Report 2026-04-01 · Ongoing
- Z-1617-2026openFDA record
Philips Respironics, Inc.
Philips Respironics Trilogy Evo Universal, Software Version 1.05.15.00. Continuous home-use ventilator device.
Reason: Using non-pneumatic nebulizers with Trilogy Evo Platform ventilators may result in a discrepancy between the set tidal volume and the tidal volume received by the patient.
Device · initiated 2026-03-02 · Enforcement Report 2026-04-01 · Ongoing
Class II48 recallsShow all
- D-0418-2026openFDA record
Amerisource Health Services LLC
Meclizine Hydrochloride Tablets, USP 12.5 mg, (a) 50 Tablets [5 x 10] (NDC 60687-775-65) (b) 12.5 mg Individual Dose ( NDC 60687-775-11), Rx Only, Distributed by: American Health Packaging, Columbus, Ohio, 43217.
Reason: Failed tablet specifications.
Drug · initiated 2026-03-16 · Enforcement Report 2026-04-01 · Ongoing
- Z-1634-2026openFDA record
AMO Puerto Rico Manufacturing, Inc.
Brand Name: TECNIS Eyhance IOL with TECNIS Simplicity" Delivery System Product Name: TECNIS Eyhance IOL with TECNIS Simplicity" Delivery System Model/Catalog Number: DIB00 Software Version: N/A Product Description: The TECNIS SIMPLICITY" Delivery System is designed to provide a…
Reason: Due to identifying a limited quantity of intraocular lenses that may have a haptic that sticks to the optic which prevents the lens from unfolding as consistently as expected.
Device · initiated 2026-02-19 · Enforcement Report 2026-04-01 · Ongoing
- Z-1609-2026openFDA record
Beckman Coulter, Inc.
MicroScan Neg MIC 56 REF C42464 UDI-DI code: 15099590731212 MicroScan panels are designed for use in determining antimicrobial agent susceptibility and/or identification to the species level of aerobic and facultatively anaerobic gram-negative bacilli.
Reason: Due to the likely presence of contamination in well(s).
Device · initiated 2025-07-24 · Enforcement Report 2026-04-01 · Ongoing
- Z-1645-2026openFDA record
CareFusion 303, Inc.
BD Alaris" System with Guardrails" Suite MX with Point of Care Unit
Reason: Due to product labeling not indicating which Transport Layer Security (TLS) version that must be enabled on hospital network to ensure secure Wi-Fi communication with Point-of-Care Units
Device · initiated 2026-02-11 · Enforcement Report 2026-04-01 · Ongoing
- D-0402-2026openFDA record
Chiesi USA, Inc.
CUROSURF (poractant alfa), 240 mg, Intratracheal Suspension, 3L Single-dose-Vial, Rx only, Chiesi USA, Inc, Cary, NC 27518, NDC 10122-510-03.
Reason: Lack of Assurance of Sterility
Drug · initiated 2026-03-17 · Enforcement Report 2026-04-01 · Ongoing
- Z-1590-2026openFDA record
GE Medical Systems, LLC
Imactis CT-Navigation System, stereotaxic accessory for Computer Tomography (CT), systems, Model Numbers E85101LA and E85101LP
Reason: There is a potential issue that can lead to discordance between the simulated needle trajectory/tip position and the actual needle trajectory/tip position.
Device · initiated 2026-02-03 · Enforcement Report 2026-04-01 · Ongoing
- Z-1592-2026openFDA record
I.T.S. GmbH
Volar Radius Plate with Angular Stability with the following description: Radius Plate PROlock II. Article Numbers: 21031-3, 21031-5, 21032-11, 21032-3, 21032-5, 21033-3, 21033-5, 21034-3, 21034-5, 21035-3, 21036-3.
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1593-2026openFDA record
I.T.S. GmbH
Claviculaplate with Angular Stability, with the below descriptions and associated article numbers. 1. Anterior Clavicle Plate, Medial; Article Numbers: 21116-8, 21117-10, 21118-10. 2. Clavicle Plate; Article Numbers: 21121-6, 21121-8. 3. Clavicle Plate, 3.5mm; Article Numbers: 2…
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1594-2026openFDA record
I.T.S. GmbH
Brand Name: Humeral Head Plate with Angular Stability, with the following description: Proximal Humeral Plate. Article Numbers: 211341-10, 211341-4, 211341-7, 21134-4, 21134-5, 21135-4, 21136-4, 21136-5, 21136-7, 21137-4, 21137-7, 21138-4, 21139-4.
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1595-2026openFDA record
I.T.S. GmbH
FR.O.H. Calcaneus Repair System with the following description: Anterolateral Calcaneus Plate. Article Number: 21064-60.
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1596-2026openFDA record
I.T.S. GmbH
Pilonplate with Angular Stability, with the below descriptions and corresponding article numbers. 1. Anterolateral Tibia Plate; Article Numbers: 21311-11, 21311-15, 21311-7, 21312-11, 21312-15, 21312-7. 2. Pilon Plate 4mm; Article Numbers: 21094-10, 21094-4, 21094-6, 21094-8. 3.…
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1597-2026openFDA record
I.T.S. GmbH
Olecranonplate with Angular Stability with the below descriptions and corresponding article numbers. 1. Olecranon Hook Plate; Article Numbers: 21112-7, 21114-5, 21113-9. 2. Olecranon Plate; Article Numbers: 21111-6, 21111-8, 21111-12.
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1598-2026openFDA record
I.T.S. GmbH
I.T.S. Straight Plate with Angular Stability with the below descriptions and corresponding article numbers. 1. Forearm Plate, Curved; Article Numbers: 21604-6, 21604-9. 2. Forearm Plate, Straight; Article Numbers: 21605-11, 21605-6, 21605-9. 3. Straight Compression Plate; Articl…
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1599-2026openFDA record
I.T.S. GmbH
I.T.S. Screw System with the below descriptions and corresponding article numbers. 1. Cancellous Screw, Cannulated; Article Numbers: 31404-16, 31404-18, 31404-20, 31404-22, 31404-24, 31404-26, 31404-28, 31404-30, 31404-32, 31404-34, 31404-36, 31404-38, 31404-40, 31404-42, 31404-…
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1600-2026openFDA record
I.T.S. GmbH
Pelvic Reconstruction System (PRS) with the below descriptions and corresponding article numbers. 1. Fixation Screw; Article Number: 70312. 2. Spike short; Article Number: 70314.
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1601-2026openFDA record
I.T.S. GmbH
I.T.S. Fibula Plate PROlock with Angular Stability with the below descriptions and corresponding article numbers. 1. Distal Tubular Plate; Article Numbers: 21602-3, 21602-4, 21602-5, 21602-6, 21602-7, 21602-8, 21603-3, 21603-4, 21603-5, 21603-6, 21603-7, 21603-8. 2. Fibula Plate…
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1602-2026openFDA record
I.T.S. GmbH
Distal Humeral Plates with Angular Stability with the below descriptions and corresponding article numbers. 1. Cortical Screw, Locking; Article Numbers: 37351-10-N, 37351-12-N, 37351-14-N, 37351-16-N, 37351-18-N, 37351-20-N, 37351-22-N, 37351-24-N, 37351-26-N, 37351-28-N, 37351-…
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1603-2026openFDA record
I.T.S. GmbH
I.T.S. LRS (Locking Reconstruction System) with the below descriptions and corresponding article numbers. 1. DFL (Distal Femur Locking) Distal Femur Plate; Article Numbers: 21301-5, 21301-7, 21301-9, 21301-13, 21302-5, 21302-7, 21302-9, 21302-13. 2. PTL (Proximal Lateral Tibia L…
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1604-2026openFDA record
I.T.S. GmbH
I.T.S. DUL (Distal Ulna Locking) System and UOL (Ulna Osteotomy Locking) System with the below descriptions and corresponding article numbers. 1. I.T.S. DUL (Distal Ulna Locking) System, Distal Ulna Plate; Article Numbers: 21232-3, 21232-4, 21232-6, 21233-3, 21233-4, 21233-6, 21…
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1605-2026openFDA record
I.T.S. GmbH
FLS - Foot Locking Plates System and HOL - Hallux Osteotomy Locking Plate with the below descriptions and corresponding article numbers. 1. FLS - Foot Locking Plates System, Cancellous Stabilization Screw; Article Numbers: 37303-10, 37303-12, 37303-14, 37303-16, 37303-18, 37303-…
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1606-2026openFDA record
I.T.S. GmbH
HCS - Headless Compression Screw System, Headless Compression Screw, Cannulated; Article Numbers: 31207-10, 31207-12, 31207-14, 31207-16, 31207-18, 31207-20, 31207-24, 31207-26, 31207-28, 31207-30, 31257-12, 31257-14, 31257-16, 31257-18, 31257-20, 31257-22, 31257-24, 31257-28, 3…
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1607-2026openFDA record
I.T.S. GmbH
HLS - Hand Locking Plates System with the below descriptions and corresponding article numbers. 1. Cortical Screw; Article Numbers: 32151-6, 32151-8, 32151-9, 32151-10, 32151-11, 32151-12, 32151-13, 32151-14, 32151-15, 32151-16, 32151-18, 32151-20. 2. HLS Plate, 2 T-Shape; Artic…
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1608-2026openFDA record
I.T.S. GmbH
Brand Name: I.T.S. Pelvic Reconstruction System (PRS RX & PRS Phoenix) with the below descriptions and corresponding article numbers. 1. Anterior Column Plate; Article Numbers: 21218-16, 21219-16. 2. Anterior Column Plate; Article Numbers: 21218-14, 21219-14. 3. Biplanar 2-Colum…
Reason: Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Device · initiated 2026-01-23 · Enforcement Report 2026-04-01 · Ongoing
- Z-1631-2026openFDA record
Koven Technology, Inc.
Brand Name: BiDop 3 Product Name: BiDop 3 Pocket Doppler (ES-100V3) with BT2M20S8C fetal probe Model/Catalog Number: ES-100V3 (device); BT2M20S8C (2 MHz fetal probe). Software Version: N/A Product Description: Hand-held, battery-powered ultrasonic Doppler blood-flow detector wit…
Reason: Product labeling includes a fetal indication for use that is not cleared under its 510(k).
Device · initiated 2026-03-04 · Enforcement Report 2026-04-01 · Ongoing
- D-0403-2026openFDA record
MACLEODS PHARMA USA, INC
Levothyroxine Sodium Tablets USP 150 mcg, 1000 Tablets bottle, Rx Only, Manufactured for: Macleods Pharma USA, Inc., Princeton, NJ, Manufactured by: Macleods Pharmaceuticals Ltd., Sarigam, Valsad, Guajarat, INDIA NDC 33342-401-44
Reason: Subpotent Drug
Drug · initiated 2026-02-26 · Enforcement Report 2026-04-01 · Ongoing
- Z-1650-2026openFDA record
Medline Industries, LP
Puracol and Puracol Plus Collagen Wound Dressings: MSC8522 DRESSING,COLLAGEN,PURACOL,STRL,2" X 2" MSC8622EP DRESSING,COLLAGEN,PURACOL PLUS, 2X2.2"
Reason: Elevated endotoxin levels identified in affected lots. Issue may elicit strong inflammatory response if used, including local tissue irritation, delayed wound healing, or systemic effects such as fever and hypotension. In severe cases, septic shock may result.
Device · initiated 2026-02-10 · Enforcement Report 2026-04-01 · Ongoing
- Z-1635-2026openFDA record
Medtronic MiniMed, Inc.
MiniMed" 780G - MMT-1884 MiniMed" 780G - MMT-1886 With Software 6.60 and 6.61
Reason: Three software defects (Pump Error 53, BG check, and Critical Pump Error (Open Book Image)) that occurred as a result of software updates (versions 6.60, 6.61, and 6.62), which could result in a risk of hypoglycemia or hyperglycemia due to inaccuracies in insulin delivery (eithe…
Device · initiated 2026-01-30 · Enforcement Report 2026-04-01 · Ongoing
- Z-1610-2026openFDA record
Olympus Corporation of the Americas
Olympus Endoscope Suction Valve - MAJ-1443. Model Number: MAJ-1443.
Reason: The MAJ-1443 and MAJ-1444 are no longer reprocessing compatible with the OER-Pro and OER-Elite automated endoscope reprocessors.
Device · initiated 2026-02-12 · Enforcement Report 2026-04-01 · Ongoing
- Z-1611-2026openFDA record
Olympus Corporation of the Americas
Olympus Endoscope Air/Water Valve - MAJ-1444. Model Number: MAJ-1444.
Reason: The MAJ-1443 and MAJ-1444 are no longer reprocessing compatible with the OER-Pro and OER-Elite automated endoscope reprocessors.
Device · initiated 2026-02-12 · Enforcement Report 2026-04-01 · Ongoing
- Z-1612-2026openFDA record
Olympus Corporation of the Americas
Olympus Endoscope Reprocessor OER-Elite. Model Number: N5789340.
Reason: The MAJ-1443 and MAJ-1444 are no longer reprocessing compatible with the OER-Pro and OER-Elite automated endoscope reprocessors.
Device · initiated 2026-02-12 · Enforcement Report 2026-04-01 · Ongoing
- Z-1613-2026openFDA record
Olympus Corporation of the Americas
Olympus Endoscope Reprocessor OER-Pro. Model Number: N3058140.
Reason: The MAJ-1443 and MAJ-1444 are no longer reprocessing compatible with the OER-Pro and OER-Elite automated endoscope reprocessors.
Device · initiated 2026-02-12 · Enforcement Report 2026-04-01 · Ongoing
- Z-1638-2026openFDA record
Olympus Corporation of the Americas
Brand Name: Olympus Everest Bipolar Cutting Forceps, 5 mm 33 cm Product Name: Everest Bipolar Cutting Forceps Model/Catalog Number: 3005 Product Description: The OLYMPUS Everest Bipolar Cutting Forceps are intended to be passed through a 5 mm cannula. Coagulation is achieved usi…
Reason: Olympus identified that the Cutting Forceps contain components for which the supplier did not adequately validate the welding process. Defective welds can result in the Cutting Forceps' jaw breaking during clinical use.
Device · initiated 2026-02-25 · Enforcement Report 2026-04-01 · Ongoing
- Z-1639-2026openFDA record
Olympus Corporation of the Americas
Brand Name: Olympus Everest Bipolar Cutting Forceps w/Cord, 5mm 33 cm Product Name: Everest Bipolar Cutting Forceps Model/Catalog Number: 3006 Product Description: The OLYMPUS Everest Bipolar Cutting Forceps are intended to be passed through a 5 mm cannula. Coagulation is achiev…
Reason: Olympus identified that the Cutting Forceps contain components for which the supplier did not adequately validate the welding process. Defective welds can result in the Cutting Forceps' jaw breaking during clinical use.
Device · initiated 2026-02-25 · Enforcement Report 2026-04-01 · Ongoing
- Z-1640-2026openFDA record
Olympus Corporation of the Americas
Brand Name: Olympus PK Cutting Forceps, 5mm 33cm Product Name: PK Cutting Forceps Model/Catalog Number: PK-CF0533 Product Description: An assembly of devices intended to generate and apply radio-frequency (RF) alternating current to soft tissues for cutting and coagulation durin…
Reason: Olympus identified that the Cutting Forceps contain components for which the supplier did not adequately validate the welding process. Defective welds can result in the Cutting Forceps' jaw breaking during clinical use.
Device · initiated 2026-02-25 · Enforcement Report 2026-04-01 · Ongoing
- Z-1641-2026openFDA record
Olympus Corporation of the Americas
Brand Name: Olympus HALO PKS Cutting Forceps, 5mm 33cm Product Name: HALO PKS Cutting Forceps Model/Catalog Number: HACF0533 Product Description: The HALO PKS Cutting Forceps are intended to be passed through a 5 mm laparoscopic cannula. Coagulation is achieved using electrosurg…
Reason: Olympus identified that the Cutting Forceps contain components for which the supplier did not adequately validate the welding process. Defective welds can result in the Cutting Forceps' jaw breaking during clinical use.
Device · initiated 2026-02-25 · Enforcement Report 2026-04-01 · Ongoing
- Z-1642-2026openFDA record
Olympus Corporation of the Americas
Brand Name: Olympus PKS Cutting Forceps, 5mm 33cm Product Name: PKS Cutting Forceps Model/Catalog Number: 3005PK Product Description: The PKS Cutting Forceps are intended to be passed through a 5mm cannula. Coagulation is achieved using electrosurgical energy under visualization…
Reason: Olympus identified that the Cutting Forceps contain components for which the supplier did not adequately validate the welding process. Defective welds can result in the Cutting Forceps' jaw breaking during clinical use.
Device · initiated 2026-02-25 · Enforcement Report 2026-04-01 · Ongoing
- Z-1643-2026openFDA record
Olympus Corporation of the Americas
Brand Name: Olympus PKS Cutting Forceps w/Cord, 5mm 24cm Product Name: PKS Cutting Forceps Model/Catalog Number: 920000PK Product Description: The PKS Cutting Forceps are intended to be passed through a 5mm cannula. Coagulation is achieved using electrosurgical energy under visu…
Reason: Olympus identified that the Cutting Forceps contain components for which the supplier did not adequately validate the welding process. Defective welds can result in the Cutting Forceps' jaw breaking during clinical use.
Device · initiated 2026-02-25 · Enforcement Report 2026-04-01 · Ongoing
- Z-1644-2026openFDA record
Olympus Corporation of the Americas
Brand Name: Olympus PKS Cutting Forceps, 5mm 33cm Product Name: PKS Cutting Forceps Model/Catalog Number: 920005PK Product Description: The PKS Cutting Forceps are intended to be passed through a 5mm cannula. Coagulation is achieved using electrosurgical energy under visualizati…
Reason: Olympus identified that the Cutting Forceps contain components for which the supplier did not adequately validate the welding process. Defective welds can result in the Cutting Forceps' jaw breaking during clinical use.
Device · initiated 2026-02-25 · Enforcement Report 2026-04-01 · Ongoing
- Z-1629-2026openFDA record
Orthalign, Inc
Drill Plate, Ortho Dev. Trimax - Pegged, PREF Size 1 -5 REF:402566 component Lantern Knee System
Reason: Drill plates manufactured out of specification can result in a bone cut in excess 00800"(2.8448mm)
Device · initiated 2026-02-10 · Enforcement Report 2026-04-01 · Ongoing
- Z-1630-2026openFDA record
Orthalign, Inc
Drill Plate, Ortho Dev. Trimax - Pegged, PREF Size 6-7 REF:402567 component Lantern Knee System
Reason: Drill plates manufactured out of specification can result in a bone cut in excess 00800"(2.8448mm)
Device · initiated 2026-02-10 · Enforcement Report 2026-04-01 · Ongoing
- Z-1632-2026openFDA record
Straumann USA LLC
Custom Abutment Ti, for Straumann RC, incl. TAN screw; Catalog Number/Art.: 027.4620;
Reason: A material mix-up had occurred during the manufacturing of Straumann¿ Custom Abutments. More specifically, a raw material bar of TAN-material (SAP #701924 / Lot 7130439) was incorrectly identified as a Titanium Bar Ti Gr4 D (SAP #701922 / Lot 7130430). As a result, RC Titanium a…
Device · initiated 2026-03-17 · Enforcement Report 2026-04-01 · Ongoing
- Z-1633-2026openFDA record
Straumann USA LLC
Custom Abutment AS Ti, for Straumann RC, incl. TAN screw; Catalog Number/Art.: 010.5438;
Reason: A material mix-up had occurred during the manufacturing of Straumann¿ Custom Abutments. More specifically, a raw material bar of TAN-material (SAP #701924 / Lot 7130439) was incorrectly identified as a Titanium Bar Ti Gr4 D (SAP #701922 / Lot 7130430). As a result, RC Titanium a…
Device · initiated 2026-03-17 · Enforcement Report 2026-04-01 · Ongoing
- Z-1636-2026openFDA record
Tandem Diabetes Care, Inc.
Tandem pumps are battery-operated infusion pumps capable of both basal and bolus delivery of insulin. The pumps utilize a motor-driven mechanism to deliver insulin from within a disposable cartridge, through an infusion set, into a patient s subcutaneous tissue. As with current…
Reason: The Czech language user guide contained multiple translation errors. The most significant error was that it incorrectly instructs users to verify that the infusion set is connected to the body, when it should instead direct users to confirm that the infusion set is not connected…
Device · initiated 2026-01-30 · Enforcement Report 2026-04-01 · Ongoing
- D-0404-2026openFDA record
Teva Pharmaceuticals USA, Inc
Octreotide Acetate for Injectable Suspension, for gluteal intramuscular use, 10 mg, Single-dose 8 mL vial in Kit, Rx only, Manufactured in Greece BY: Pharmathen International S.A, Rodopi, 693 00 Greece, Manufactured For: TEVA Pharmaceuticals, Parsippany, NJ 07054, NDC 0480-9257-…
Reason: Lack of Assurance of Sterility: Quality system deficiencies identified during a routine U.S Food and Drug Administration (FDA) inspection at the contract manufacturer.
Drug · initiated 2026-03-17 · Enforcement Report 2026-04-01 · Ongoing
- D-0405-2026openFDA record
Teva Pharmaceuticals USA, Inc
Octreotide Acetate for Injectable Suspension, for gluteal intramuscular use, 20 mg, Single-dose 8 mL vial in Kit, Rx only, Manufactured in Greece BY: Pharmathen International S.A, Rodopi, 693 00 Greece, Manufactured For: TEVA Pharmaceuticals, Parsippany, NJ 07054, NDC 0480-9259-…
Reason: Lack of Assurance of Sterility: Quality system deficiencies identified during a routine U.S Food and Drug Administration (FDA) inspection at the contract manufacturer.
Drug · initiated 2026-03-17 · Enforcement Report 2026-04-01 · Ongoing
- D-0406-2026openFDA record
Teva Pharmaceuticals USA, Inc
Octreotide Acetate for Injectable Suspension, for gluteal intramuscular use, 30 mg, Single-dose 8 mL vial in Kit, Rx only, Manufactured in Greece BY: Pharmathen International S.A, Rodopi, 693 00 Greece, Manufactured For: TEVA Pharmaceuticals, Parsippany, NJ 07054, NDC 0480-9262-…
Reason: Lack of Assurance of Sterility: Quality system deficiencies identified during a routine U.S Food and Drug Administration (FDA) inspection at the contract manufacturer.
Drug · initiated 2026-03-17 · Enforcement Report 2026-04-01 · Ongoing
- Z-1651-2026openFDA record
Waldemar Link GmbH & Co. KG (Mfg Site)
Embrace Drill Tower, Wedged (25mm); Item Number: 645-081/62;
Reason: The surgical technique for the Embrace Shoulder Instruments - Drill Tower has mixed-up article numbers in the overview of the instruments. However, the individual surgical steps described in the surgical technique are correct.
Device · initiated 2026-02-11 · Enforcement Report 2026-04-01 · Ongoing
- Z-1652-2026openFDA record
Waldemar Link GmbH & Co. KG (Mfg Site)
Embrace Drill Tower, Standard/Lateral (25mm); Item Number: 645-081/63;
Reason: The surgical technique for the Embrace Shoulder Instruments - Drill Tower has mixed-up article numbers in the overview of the instruments. However, the individual surgical steps described in the surgical technique are correct.
Device · initiated 2026-02-11 · Enforcement Report 2026-04-01 · Ongoing
Class III12 recallsShow all
- Z-1618-2026openFDA record
Philips Ultrasound, Inc
Philips 3D6-2 Ultrasound Transducer
Reason: To provide clarification and labelling to define the useful life of ultrasound transducers in the field.
Device · initiated 2025-09-05 · Enforcement Report 2026-04-01 · Ongoing
- Z-1619-2026openFDA record
Philips Ultrasound, Inc
Philips C9-4 Ultrasound Transducer
Reason: To provide clarification and labelling to define the useful life of ultrasound transducers in the field.
Device · initiated 2025-09-05 · Enforcement Report 2026-04-01 · Ongoing
- Z-1620-2026openFDA record
Philips Ultrasound, Inc
Philips L12-5 Ultrasound Transducer
Reason: To provide clarification and labelling to define the useful life of ultrasound transducers in the field.
Device · initiated 2025-09-05 · Enforcement Report 2026-04-01 · Ongoing
- Z-1621-2026openFDA record
Philips Ultrasound, Inc
Philips L17-5 Ultrasound Transducer
Reason: To provide clarification and labelling to define the useful life of ultrasound transducers in the field.
Device · initiated 2025-09-05 · Enforcement Report 2026-04-01 · Ongoing
- Z-1622-2026openFDA record
Philips Ultrasound, Inc
Philips Mini Multi TEE Ultrasound Transducer
Reason: To provide clarification and labelling to define the useful life of ultrasound transducers in the field.
Device · initiated 2025-09-05 · Enforcement Report 2026-04-01 · Ongoing
- Z-1623-2026openFDA record
Philips Ultrasound, Inc
Philips OMNI II TEE Ultrasound Transducer
Reason: To provide clarification and labelling to define the useful life of ultrasound transducers in the field.
Device · initiated 2025-09-05 · Enforcement Report 2026-04-01 · Ongoing
- Z-1624-2026openFDA record
Philips Ultrasound, Inc
Philips OMNI III TEE Ultrasound Transducer
Reason: To provide clarification and labelling to define the useful life of ultrasound transducers in the field.
Device · initiated 2025-09-05 · Enforcement Report 2026-04-01 · Ongoing
- Z-1625-2026openFDA record
Philips Ultrasound, Inc
Philips S4-1 Ultrasound Transducer
Reason: To provide clarification and labelling to define the useful life of ultrasound transducers in the field.
Device · initiated 2025-09-05 · Enforcement Report 2026-04-01 · Ongoing
- Z-1626-2026openFDA record
Philips Ultrasound, Inc
Philips S5-2 Ultrasound Transducer
Reason: To provide clarification and labelling to define the useful life of ultrasound transducers in the field.
Device · initiated 2025-09-05 · Enforcement Report 2026-04-01 · Ongoing
- Z-1627-2026openFDA record
Philips Ultrasound, Inc
Philips X3-1 Ultrasound Transducer
Reason: To provide clarification and labelling to define the useful life of ultrasound transducers in the field.
Device · initiated 2025-09-05 · Enforcement Report 2026-04-01 · Ongoing
- Z-1628-2026openFDA record
Philips Ultrasound, Inc
Philips X7-2 Ultrasound Transducer
Reason: To provide clarification and labelling to define the useful life of ultrasound transducers in the field.
Device · initiated 2025-09-05 · Enforcement Report 2026-04-01 · Ongoing
- D-0401-2026openFDA record
Radnostix
Gelatin Capsule Pack for use with the Sodium Iodide I-131 Kit (containing 5 empty capsules and 5 Dibasic Sodium Phosphate Capsules 300 mg, International Isotopes Inc., Idaho Falls, ID 83401. NDC: 69208-003-15; 69208-003-25; 69208-003-35
Reason: Failed Tablet/Capsule Specifications
Drug · initiated 2026-02-19 · Enforcement Report 2026-04-01 · Ongoing
New OAI classifications
0 inspections classified Official Action Indicated that FDAgent first recorded from FDA's inspection classification data this week, after its reads of that data in the 8 days before had not found them. Older inspections FDAgent adds to its archive are left out. Dates are inspection end dates. Inspection classifications last synced Nov 23, 2026, 04:25 UTC.
FDAgent recorded no new OAI classifications this week.
Get this page by email every Monday
A free weekly email with each week’s warning letters, new Form 483s, OAI classifications and Class I recalls, counted the same way as this page. Just your email address.
About this data
- Weeks are ISO weeks, Monday to Sunday, in UTC. Each section is dated by its own FDA date: posting date for warning letters, reading-room publish date for Form 483s (each inspection's 483 counts once, when FDA first listed it; FDA's re-posts and amended 483s with the FEI and record date of one it listed before are shown apart), Enforcement Report date for recalls, and the date published FDA prints beside each firm on an import alert. FDA publishes no date for an inspection classification, so an OAI classification counts as new on the day FDAgent first recorded the inspection, and only when FDAgent's complete reads of FDA's inspection data in the 8 days before had covered the inspection's end date without finding it. Older inspections FDAgent adds to its archive, by a backfill or a wider read, never count as new, however late FDA posted them. Inspections FDAgent recorded before it began keeping a record of its reads, in November 2026, count only when they ended in the 13 weeks before, and the Veterinary inspections of FDAgent's first read of them, that same month, never count.
- Import alert entries come from FDA's import alert pages, where FDA lists firms by name and address, not by FEI. FDAgent links an entry to a facility only when FDA printed the firm's FEI, never by name. Earlier weeks list only entries still on FDA's pages, because FDA deletes an entry when it removes a firm, and FDAgent keeps removed entries only from the day it began recording them. FDAgent lists an entry here only when its name shows it is a firm, through a legal form such as Ltd, Inc or GmbH, a business word such as Laboratories or Trading, or a web address, or when FDA's inspection or drug registration records hold a firm under exactly that name; entries that may name a person are shown only to signed-in users.
- Import refusals are not listed by week: FDA reports a refusal weeks after it happens, so a week's count would keep changing after the week closed. Each facility page lists its own refusals.
- Warning letters are those issued by FDA's drug, biologics and device centers and their field and quality offices. Letters from FDA's food, tobacco, veterinary, cosmetics and dietary supplement offices are left out.
- FDA posts only some Form 483s to its Electronic Reading Room, so a missing 483 does not mean none was issued.
- FDA publishes an inspection's classification once it is final and updates its inspection data weekly. Source: FDA inspections FAQ.
- Recalls come from openFDA, which republishes FDA's weekly Enforcement Report; a report's recalls appear here once openFDA publishes it.
- FDAgent is independent of FDA. Every row links to its FDA source; check it before relying on a record.