Skip to content

Hikal Limited

72 - 82 / A Kiadb Industrial Area, Jigani, India

FEI 3003560263DUNS 918602129

Company: Hikal Limited · Linked by exact D-U-N-S match (918602129) in FDA registration data

FDA has 4 inspections on file for Hikal Limited in Jigani, India (FEI 3003560263), from 2011 to 2025. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. One of the five FOIA requests for this site has asked FDA for this inspection's 483.

No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant, Hikal Limited (D-U-N-S 918602129), has registered 1 other site.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
4, 2011–2025
1 OAI · 1 VAI · 2 NAI
Inspections with 483 observations shown
1 of 4
Form 483s posted by FDA
↗
Requested under FOIA
5 requests, latest Sep 21, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Customer foreign-matter complaints

      OBSERVATION 1 Complaints are not adequately investigated, and appropriate follow ups are not performed. Specifically, Your firm has received numerous complaints of foreign matter contamination in US distributed product/API used in production batches of APL. The chart below details the varied batches of APL distributed in the US: Complaint No. Date received Date closed Product MC-026/19 09.10.2019 02.01.2020 MC-033/19 18.12.2019 04.04.2020 MC-012/20 06.05.2020 05.11.2020 MC-014/20 06.05.2020 05.11.2020 MC-020/20 12.06.2020 20.08.2020 MC-024/20 20.08.2020 03.03.2021 MC-028/20 14.10.2020 25.12.2020 MC-003/21 02.02.2021 04.05.2021 MC-004/21 05.02.2021 25.06.2021 MC-006/21 18.02.2021 02.08.2021 MC-009/21 12.04.2021 02.08.2021 MC-010/21 17.06.2021 03.09.2021 MC-030/21 12/7/2021 4/20/2022 MC-001/22 18.01.2022 3/14/2022 MC-002/22 19.01.2022 3/28/2022 MC-010/22 02.05.2022 12/21/2022 MC-015/22 08.06.2022 5/2/2023 MC-023/22 25.08.2022 5/2/2023 MC-024/22 27.08.2022 11/28/2022 MC-027/22 28.09.2022 5/2/2023 MC-029/22 07.11.2022 3/30/2023 MC-030/22 08.11.2022 5/3/2023 MC-031/22 10.11.2022 07.02.2023 MC-036/22 24.11.2022 8/21/2023 MC-004/23 26.01.2023 02.05.2023 MC-010/23 10.03.2023 11/05/2023 MC-012/23 13.03.2023 10/10/2023 MC-039/23 03.10.2023 11/12/2023 MC-043/23 30.11.2023 27.02.2024 MC-044/23 01.12.2023 14.05.2024 MC-007/24 18.03.2024 19.06.2024 MC-010/24 06.04/2024 12.08.2024 MC-019/24 18.07.2024 09.12.2024 MC-020/24 01.08.2024 11/12/2024 MC-028/24 09/25/2024 1/31/2025 MC-029/24 10/02/2024 11/4/2024 MC-030/24 10/14/2024 06.12.2024 Foreign matter contamination has been steadily reported to your firm, by customers, since the last FDA inspection (conducted from 7/29/2019 to 8/2/2019).

    2. Observation 2

      OOS results invalidated without justification

      OBSERVATION 2 Out-Of-Specification (OOS) results are routinely invalidated, without sufficient supporting evidence or scientific justification of the root cause. Specifically, Of 92 invalidated OOS results relating to US distributed product, 24 investigations were invalidated without establishing a root cause, with conforming retest results accepted and batches released.

    Show observations 3 to 6
    1. Observation 3

      Maintenance/calibration and metal detection gaps

      OBSERVATION 3 Appropriate maintenance and calibration of critical equipment is deficient. There is no assurance that API and intermediate production blocks are free from metal. The firm received repeated and continuous complaints regarding potential metal contamination in APIs. During the inspection it was determined that your firm does not routinely challenge the ability of unit production blocks to detect metal. Observe that your firm's Unit site does not possess certified [illegible]. The Unit site manufactures the following API distributed in the US.

    2. Observation 4

      Deficient vendor qualification procedure

      OBSERVATION 4 Written procedures are deficient specifically. A. Your firm's vendor qualification procedure, CQA01002-01, indicates that vendors are assessed on the number of consecutive rejections encountered during incoming material inspection. There is no provision for vendors that provide materials that are identified post-distribution (for example, your [illegible] drums and lids supplied by [vendor name redacted]. A vendor audit was performed by your firm's personnel in April 2024, to which despite a bevy of procedural changes, facility improvements and [illegible], drum fibers and pieces of the lids continued with a "zero-rejection rate", despite the continuous nature of received complaints. Several vendors have been qualified; however, according to [illegible], they provide approximately greater than [illegible] and are not fully verified.

    3. Observation 5

      Insufficient protection of backup data

      OBSERVATION 5 Back-up data is not appropriately protected from unauthorized access, manipulation or deletion. Specifically, During a walkthrough of your firm's microbiology laboratory, a "qc" folder located on the server (IP: 172.21.21.25) contained a folder titled "CHROMELEON 6.8 BACKUP BEFORE MIGRAGTION". The folder and contained files had no file protection and were fully accessible and able to be deleted while logged in Microbiology, although the deletion process was aborted to preserve data. During the microbiology laboratory walkthrough, your firm's IT personnel were seemingly unaware that the Chromeleon backup data was saved to user file folders and not the designated IT Folder/Backup System. The backup folder contained equipment [illegible].

    4. Observation 6

      Unrecorded computerized system events

      OBSERVATION 6 Incidents related to computerized systems that could affect the quality are not recorded and investigated. Specifically, Your firm's process equipment includes a Logic Controller (PLC) in conjunction with a Human Machine Interface (HMI-16). Events encountered generate a temporary notification visually on the HMI, and personnel are expected to contact the engineering department. However, neither the computerized system/software used to manage the process, nor the written procedure/production batch record require any documentation of the events encountered. Upon request, your firm could not provide a single documented instance of any of the 37 events requiring engineering department notification since installation of the system. There is no mechanism to assess the adequacy of the processing system events.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on Sep 21, 2026.

  • Inspection ending Feb 7, 2025OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Mar 23, 2026FDA-FOIA-2026-2856Form 483Records released
  • Inspection ending Aug 2, 2019VAI

    3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 + EIR on Oct 14, 2026. FDAgent holds no copy that FDA posted.

    1. Sep 21, 2026FDA-FOIA-2026-9128Form 483 + EIRRecords released
    2. May 20, 2022FDA-FOIA-2022-3704Form 483Closed
    3. Mar 29, 2021FDA-FOIA-2021-2050Form 483 + EIRClosed
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Feb 14, 2025FDA-FOIA-2025-1491Inspection recordsClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2027
Registrant
Hikal LimitedD-U-N-S 918602129

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Hikal Limited (D-U-N-S 918602129) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • Hikal LimitedPanoli, Bharuch District, India · FEI 30096272832 inspections2latestMay 12, 2023NAINone on file

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3003560263 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3003560263. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.