21 CFR 58.120: Protocol
FDA's inspection data lists 3 Form 483 citations of 21 CFR 58.120 at 1 facility, from September 2014 to September 12, 2014.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 3
- At 1 inspection
- Facilities cited
- 1
- Distinct FEIs
- Most recent citation
- Sep 12, 2014
- Incumedx LLC
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 58.120 from the Electronic Code of Federal Regulations.
§ 58.120 Protocol.
(a) Each study shall have an approved written protocol that clearly indicates the objectives and all methods for the conduct of the study. The protocol shall contain, as applicable, the following information:
(1) A descriptive title and statement of the purpose of the study.
(2) Identification of the test and control articles by name, chemical abstract number, or code number.
(3) The name of the sponsor and the name and address of the testing facility at which the study is being conducted.
(4) The number, body weight range, sex, source of supply, species, strain, substrain, and age of the test system.
(5) The procedure for identification of the test system.
(6) A description of the experimental design, including the methods for the control of bias.
(7) A description and/or identification of the diet used in the study as well as solvents, emulsifiers, and/or other materials used to solubilize or suspend the test or control articles before mixing with the carrier. The description shall include specifications for acceptable levels of contaminants that are reasonably expected to be present in the dietary materials and are known to be capable of interfering with the purpose or conduct of the study if present at levels greater than established by the specifications.
(8) Each dosage level, expressed in milligrams per kilogram of body weight or other appropriate units, of the test or control article to be administered and the method and frequency of administration.
(9) The type and frequency of tests, analyses, and measurements to be made.
(10) The records to be maintained.
(11) The date of approval of the protocol by the sponsor and the dated signature of the study director.
(12) A statement of the proposed statistical methods to be used.
(b) All changes in or revisions of an approved protocol and the reasons therefore shall be documented, signed by the study director, dated, and maintained with the protocol.
21 CFR Part 58: Good Laboratory Practice for Nonclinical Laboratory Studies, Subpart GRead on eCFR
Citations by year
Form 483 citations of 21 CFR 58.120 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 3 in 2014
| Year | Form 483 citations |
|---|---|
| 2014 | 3 |
How FDA words this citation
FDA's short descriptions and citation text on these 3 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Protocol: date and signature1 citations
- Protocol: experimental design1 citations
- Protocol: sponsor name and address1 citations
Citation text
- “Not all protocols contained a description of the experimental design, including the methods for the control of bias.”1 citations
- “Not all protocols contained the date of approval of the protocol by the sponsor and the dated signature of the study director.”1 citations
- “Not all protocols contained the name of the sponsor and the name and address of the testing facility at which the study is being conducted.”1 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 58.120, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
Often cited at the same inspection
Of the 1 inspection where FDA cited 21 CFR 58.120, the share where it also cited each of these sections.
- 21 CFR 58.10Applicability to studies performed under grants and contracts1 (100%)
- 21 CFR 58.185Reporting of nonclinical laboratory study results1 (100%)
- 21 CFR 58.190Storage and retrieval of records and data1 (100%)
Ask FDAgent about 21 CFR 58.120
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 58.120; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.