Gram Peptides warning letter, March 31, 2026
FDA's Center for Drug Evaluation and Research (CDER) issued this warning letter to Gram Peptides of Rancho Santa Fe, CA on March 31, 2026 and posted it on April 7, 2026. FDA lists its subject as Unapproved New Drugs Sold Over the Internet.
Source: FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Read the full letter on fda.gov. FDAgent is independent of FDA.
- Issued
- Mar 31, 2026
- By CDER
- Posted by FDA
- Apr 7, 2026
- 7 days after issue
- Subject
- Unapproved New Drugs Sold Over the Internet
- As FDA lists it
- FDA reference
- MARCS-CMS 721806
- FDA's case number
Violations FDA states in this letter
This letter states no violation sentence that cites a 21 CFR section FDAgent can quote. The full letter is below.
The facility
FDA's compliance action record for this letter (case 721806) names one facility. Each facility's FDA record on FDAgent has its full inspection history.
The letter
FDA's text of the letter as posted on fda.gov. FDAgent leaves out the address block, the greeting and the copy list, which name the people it was sent to.
This letter is to advise you that the U.S. Food and Drug Administration (FDA) reviewed your website at https://grampeptides.com from January to March 2026. The FDA has observed that your website offers “Retatrutide” (also referred to by your firm as “GLP-1-R peptide”) and “Tirzepatide” (also referred to by your firm as “GLP-2 peptide”) and “Bacteriostatic Water for Injection” (hereinafter Gram Peptides products) for sale in the United States. Based on our review, these products are unapproved new drugs under section 505(a) of the Federal Food, Drug, and Cosmetic Act (FD&C Act), 21 U.S.C. 355(a). As explained further below, introducing or delivering these products for introduction into interstate commerce violates sections 301(d) and 505(a) of the FD&C Act, 21 U.S.C. 331(d) and 355(a).
These products are especially concerning from a public health perspective because injectable drug products can pose risks of serious harm to users. Injectable products are delivered directly into the body, sometimes directly into the bloodstream, and therefore, bypass some of the body’s key defenses against toxins and microorganisms that can lead to serious and life-threatening conditions.
Despite statements on your product labeling marketing your products for “Research Use Only,” and “not intended for human consumption, medical use, or veterinary use,” evidence obtained from your website establishes that your products are intended to be drugs for human use. Your products are drugs as defined by section 201(g)(1) of the FD&C Act 21, U.S.C. 321(g)(1), because they are intended for use in the diagnosis, cure, mitigation, treatment, or prevention of disease and/or intended to affect the structure or function of the body.
Examples from your product labeling, including on your website, that provide evidence of the intended use (as defined in 21 CFR 201.128) of these products as drugs include, but may not be limited to, the following:
Retatrutide (also referred to as “GLP-1-R Peptide”) On the webpage https://grampeptides.com/product/retatrutide/:
- “[I]nfluences appetite suppression, insulin sensitivity, thermogenesis, and fat-oxidation models.”
- “[D]emonstrated significant potential for reducing body weight, improving glucose handling, and enhancing lipid metabolism.”
- “GLP-1-R peptide acts through coordinated activation of: GLP-1 receptors – improving glucose response, slowing gastric emptying, and reducing appetite.”
Tirzepatide (also referred to as “GLP-2 Peptide”) On the webpage https://grampeptides.com/product/tirzepatide/:
- “Benefits of GLP-2 Peptide . . . o Metabolic Regulation – Studied for its ability to lower glucose and support balanced insulin levels. o Weight Management – Associated with significant decreases in body weight in both animal and human studies. o Improved Lipid Profiles – Research shows reductions in triglycerides and improved cholesterol ratios.”
Bacteriostatic Water for Injection Your firm offers “Bacteriostatic Water for Injection” for sale alongside peptide products, which are drugs intended for injection and require reconstitution, including the two above-mentioned GLP products. The sale of these products together demonstrates that you intend for your “Bacteriostatic Water for Injection” to be used in combination for injection. Therefore, your “Bacteriostatic Water for Injection” is a drug.
Your Gram Peptides products are “new drugs” under section 201(p) of the FD&C Act, 21 U.S.C. 321(p), because they are not generally recognized as safe and effective (GRASE) for use under the above-described conditions prescribed, recommended, or suggested in their labeling. With certain exceptions not applicable here, a new drug may not be introduced or delivered for introduction into interstate commerce without an approved application from FDA in effect, as described in section 505(a) of the FD&C Act, 21 U.S.C. 355(a). No approved applications pursuant to section 505 of the FD&C Act, 21 U.S.C. 355, are in effect for these products. Accordingly, these products are unapproved new drugs. The introduction or delivery for introduction into interstate commerce of these unapproved new drug products violates sections 301(d) and 505(a) of the FD&C Act, 21 U.S.C. 331(d) and 355(a).
The violations cited in this letter are not intended to be an all-inclusive statement of violations that may exist in connection with your products. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations. It is your responsibility to ensure that your firm complies with all requirements of federal law, including FDA regulations.
This letter notifies you of our concerns and provides you an opportunity to address them. Failure to adequately address this matter may lead to regulatory or legal action including, without limitation, seizure and injunction.
Please notify FDA in writing, within fifteen working days of receipt of this letter, of the specific steps you have taken to correct any violations. Include an explanation of each step being taken to prevent the recurrence of violations, as well as copies of related documentation. If you believe that your products are not in violation of the FD&C Act, include your reasoning and any supporting information for our consideration. If you cannot complete corrective action within fifteen working days, state the reason for the delay and the time within which you will complete the correction.
Your response should be sent to U.S. Food and Drug Administration, CDER/OC/Office of Unapproved Drugs and Labeling Compliance by email to FDAAdvisory@fda.hhs.gov. Please include your firm name and the unique identifier “721806” in the subject line of the email.
Tina Smith, M.S. Captain, U.S. Public Health Service Director Office of Unapproved Drugs and Labeling Compliance Office of Compliance Center for Drug Evaluation and Research Food and Drug Administration
Ask FDAgent about this warning letter
FDAgent reads the letter, the facility's inspections and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The letter, its text, dates, issuing office and subject come from FDA's warning letter pages.
- FDAgent leaves out the letter's address block, greeting and copy list, which name the people it was sent to, and quotes each numbered violation sentence that cites 21 CFR.
- Facilities come from FDA's compliance action record for the letter's case number, or the one FEI the letter names; inspections and citations come from FDA's Data Dashboard.
- FDAgent is independent of FDA.