Taenaka Kogyo Co., Ltd. Form 483, April 2024
FDA issued this Form 483 to Taenaka Kogyo Co., Ltd. in Mobara, Japan (FEI 3003282619) at the end of a drug inspection that ended April 12, 2024. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Sep 6, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Apr 12, 2024
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Sep 6, 2024
- 147 days after the inspection
The 4 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate training for visual inspection
Training is not regularly conducted by qualified individuals, does not cover the particular operations that employees perform and GMP as it relates to the employees’ functions, and is not periodically assessed. Specifically, Your firm does not provide adequate training and assessment of employees performing visual examination of finished drug substances to ensure they are capable of observing the types of contaminants such examinations are intended to detect. Your production process for includes a 100% visual examination step in which the material is visually examined for contaminants. Your training process for operators performing these inspections does not include an assessment to determine whether or not the operators are capable of observing the types of contaminants such examinations are intended to detect. Since the beginning of 2022, your firm has manufactured, released, and distributed [Plots of this drug substance, totaling somal BR
- 2
Inadequate ventilation and pressure control
Ventilation systems, including equipment for control of air pressure, are not adequately designed and constructed to minimize risks of contamination. Specifically, The production suites used by your firm in the manufacturing of drug substance lots are not adequately equipped to prevent contamination of in-process substances from the neighboring outside environment. a) The heating, ventilation, and air conditioning (HVAC) system used to establish the specified differential pressure between the production suites and the neighboring outside environment are not sufficient to ensure this pressure differential is maintained. On 04/09/24, I observed the gauge displaying the pressure differential between the Plant [illegible] room and the outside environment drop to less than [illegible], which is below the specified range of [illegible]. Across this differential, the [illegible] Room is designed to contain higher air pressure than the outside environment to prevent unfiltered air from entering the area while in-process drug substances are exposed. b) The monitoring devices used to ensure the differential pressure between the production suites and the neighboring outside environment are not equipped with alarm systems to alert personnel to pressure excursions. The gauge displaying the pressure differential between the Plant [illegible] Room and the neighboring outside environment is not visible to production operators at work inside the suite, and no personnel are assigned to monitor the gauge while manufacturing operations are taking place inside the suite. Lots of [illegible] re substance are [illegible] the Plant [illegible] Room.
- 3
Insufficient monitoring of storage chambers
Facilities for the storage of materials under controlled temperature and humidity conditions are not sufficiently monitored to ensure the material characteristics of items stored inside them are maintained. Specifically, The controlled temperature storage chambers used by your firm to store various materials involved in GMP drug substance manufacturing operations are not monitored in a way that ensures temperature excursions are addressed in a timely manner. The alarm systems installed on such units throughout your facilities are configured to send email notifications to your Quality Control (QC) Manager, QC Test Manager, and Analytical Equipment Manager in the event one or more of the chambers experiences a temperature excursion. However, your firm has not established procedures or policies to ensure any of these personnel monitor their email for notifications outside of your office hours of 8:00 am to 5:00 pm, Monday - Friday. Chambers monitored per this system include but are not limited to the following: a) Stability chambers used to store drug substance samples held for stability studies. b) Incubators used to promote microbial growth of finished drug substance, water, and environmental monitoring samples.
- 4
Inadequate microbiological test validation
Testing designed to ensure that API specifications for microbiological purity and appropriate action limits for total microbial counts and objectionable organisms are met is not conducted in a way that ensures the validity of results. Specifically, i) The growth media plates purchased by your firm in [illegible] are not tested to demonstrate their ability to grow colonies of microorganisms, regardless of the number of media plate lots received. In 2023, your firm received [illegible] growth media plates each from manufacturer's lots [illegible]; however growth promotion testing was only performed on lot [illegible]. These plates are used to perform Total Aerobic Microbial Count and Mold Count (TAMC/TYMC) testing for the release of [illegible] drug substance lots, of which your firm has released [illegible] lots respectively since the beginning of 2022.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.