Strides Pharma Science Limited Form 483, May 2026
FDA issued this Form 483 to Strides Pharma Science Limited in Bangalore, India (FEI 3004554612) at the end of a drug inspection that ended May 20, 2026. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jul 28, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- May 20, 2026
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jul 28, 2026
- 69 days after the inspection
The 4 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Unvalidated microbial ID and data controls
OBSERVATION 1 Laboratory controls shall include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, A. Your microbiological identification method used for confirmatory identification of gq, wo and other specified microorganisms in finished drug products, raw materials, and oo has not been validated or verified for its intended use. Your firm uses the microbial identification system gg System) for confirmatory identification of microorganisms; however, you have not qualified the g, System to identify all organisms routinely tested as part of your firm's microbial limit testing (MLT) including: Al. Your firm's ve testing procedure requires [3 testing for gq } : and subsequent confirmatory identification on positive samples using the gq, System. During the inspection, all of your yy Sampling yy loops Lala sampled on oS were found positive for gq On gy on gp and were processed for confirmatory identification using an unvalidated test method on they), System which is not qualified to detect from this 44 SYyStem gym. is used for the production of US products including 09 A.2. Your firm's microbial limit test specifications and batch release records confirm that g o- is a routinely required specified organism test for multiple finished drug products, including but not limited to: [illegible] Your firm's PQ documentation acknowledges that g is absent from the standard PQ organism panel (Table y,, and that the system's ability to identify this organism is dependent on its inclusion in the gq software knowledge base, which has not been verified or documented by your firm. No supplemental qualification study, challenge testing, or vendor confirmation has been provided to demonstrate that the me System is capable of reliably identifying i isolates recovered during routine testing. A.3. Your firm uses the gq system for confirmatory identification of microorganisms including [illegible] identified from your gq system, and 06 [illegible] in raw materials, using methods that are not validated or verified, and YOUT system is not qualified to detect these microorganisms. Your firm's initial performance qualification of the pq system was carried out using gq, Organisms — gq [illegible] si ;, and does not reflect the full panel of organisms your gg system is used to identify across gq, Systems, finished products, and raw materials. B. During the inspection on ge your test results for Total Aerobic Microbial Count (TAMC) forge sampled ong ong, loop ge of the system, showed a colony count of y, CFUp mL ong, which was identified as exceeding both the alert and action limits. Your SOP GQC/072/R6, effective May 31, 2023, titled "Microbial Enumeration Tests and Tests for Specified Microorganisms," indicates in Section y, that a colony count above CFU ong is to be considered Too Numerous To Count (TNTC), which, per your procedures, requires an Out of Specification (OOS) investigation. Your firm has not had any microbiological OOS investigation in the last 3 years. Your management stated that, as individual colonies can be counted, the result is reported as g uy CFUg mL gy CFU/mL) and not as TNTC; however, your firm has not verified or established, through validation or documented justification, the upper countable colony limit for the gq method beyond they, CFU threshold defined in your SOP. C. Your firm's quality control analysts (User Type 2 — F1_Analyst) have been granted the "Modify Processing Method" privilege within the Chromeleon 7.3.2 Chromatography Data System, allowing them to alter peak integration parameters and detection settings while simultaneously viewing recalculated numerical results — including peak area counts — in the Data Processing window of the Chromatog
Shortened here; the PDF has the full text.
- 2
Missing audit trail retention/review controls
OBSERVATION 2 All records of production associated with a batch of drug product were not maintained at least one (1) year after the expiration date. Specifically, Your firm failed to retain electronic audit trail data generated by manufacturing equipment for the required period, failed to establish procedures for the review of audit trail data, and failed to ensure that audit trail review results in investigation of manufacturing anomalies. A. Electronic audit trail data for ally, and some equipment is permanently deleted after one year. Drug products manufactured on these machines carry a typical shelf life of), om As a result, audit trail data is being destroyed while product manufactured on these machines remains on the U.S. market within its expiration date. There is no assurance that the complete manufacturing history for distributed drug product lots can be reconstructed or verified. Approximately wm batches of drug products have been manufactured using these pieces of equipment since 2024, with audit trail data permanently deleted while products remain within expiry on the U.S. market. Examples include but are not limited to: Finished | Product name Mfg. Mfg. Exp Date Shelf Final Dest. goods Batch no | Date Life in Code o® ®® [illegible] B. Audit trail review for gq equipment is performed by viewing data on the Human Machine Interface (HMI) display without generating a printed or otherwise durable record of the review. No retrievable evidence exists of what the audit trail contained at the time of review or whether the review was sufficient to detect anomalies. Furthermore, this data is permanently deleted from the system after one year. C. Your firm's audit trail review procedure does not define a limit on the number of times equipment parameters may be changed during batch processing, nor does it establish a threshold of repeated parameter changes that would require investigation or deviation initiation. As a result, reviewers have no documented standard against which to evaluate whether a pattern of parameter changes during manufacture of drug products constitutes an anomaly requiring investigation. D. A single audit trail review procedure and checklist are applied to all manufacturing equipment despite fundamentally different audit trail formats, event types, parameter designations, and alarm structures across equipment types. This approach does not provide assurance that reviewers are evaluating the data elements most critical to each equipment type and does not ensure that effective review is occurring.
- 3
Inadequate cleaning; cross-contamination risk
OBSERVATION 3 Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. A | Equipment ID: | Manufacturing Suite) On May 13, 2026, during the inspection of the Manufacturing Suite, — Tablet Block, ge residues were observed on the gq, of the 5 (Equipment ID: a following a Non-Serial Changeover (NSCO) — product-to-product cleaning — after the manufacture of gq Capsules gy mg (Batch No: 4 with the equipment status label indicating "Cleaned." Your firm's Work Instruction No. F1/WI/PT/103/R2, titled "Operation and Cleaning of ©®@ "(Section — Non-Serial Cleaning), requires complete dismantling of all components including the (212) ®@ ®© until no traces of previous product are observed, ge and IPQA verification of cleanliness in dismantled condition prior to reassembly and use, as documented in Cleaning Checklist F1/WI/PT/103/F-01/R1. B. 8 | Equipment ID: 4 | Tablet Block On May 13, 2026, during the inspection of the gq, area of the Tablet Block, gq residues were observed on top of the HEPA filter housing located on the technical floor ge unit of the (Equipment ID: ®®) These residues were identified following the manufacture of the previous product, ge and prior to the commencement of manufacturing for the next product, je (intended for the US market and Rest of World). Residues identified in the Ea unit area present a potential risk of cross-contamination, as particulates in this zone may be reintroduced into the processing environment during subsequent manufacturing operations, particularly during the transition between two distinct drug products. C. min Equipment | Equipment ID: Block, ®® Area On May 12, 2026, during the inspection of they area gq Of the 44 Block, more than vs capsules from the previous batch of, Capsules, mg (Batch No: 4 were observed remaining on the manufacturing line during a Serial Changeover (SCO) — batch-to-batch cleaning — including on the conveyor, chute assemblyg, , and tubing connecting line components. This is contrary to your firm's Work Instruction No. F1/WI/PS/016/RS5, titled "Dismantling, Cleaning, Line Clearance, Assembling and Start Up off) Machine" (effective May 31, 2025), Sections g through 4 which require complete removal of all previous batch capsules from the chute assembly 4 , conveyor, and ®@. emptying of the gq , and complete removal of product from the Neha tubing prior to commencement of the subsequent batch, with [PQA verification documented in Cleaning Checklist F1/WI/PS/016/F-01/RS5. This equipment is also used in the manufacture of US-marketed products including ge si capsules.
- 4
Weak computerized recipe and access controls
OBSERVATION 4 Your firm failed to exercise controls over computerized manufacturing equipment to ensure that only authorized personnel can create and modify recipes, that obsolete or unauthorized recipes cannot be selected for commercial manufacturing, and that accurate data input is maintained across your facility's computerized systems. Specifically, A. Multiple obsolete and unauthorized recipes exist simultaneously on ge equipment with no functional mechanism to prevent their selection during commercial manufacturing. Obsolete and unauthorized recipes were observed on the following equipment: ®® ®O QL) Your firm acknowledges that obsolete recipes cannot be deleted from equipment due to system limitations. These obsolete recipes remain accessible to production supervisors during batch manufacturing, creating risk for incorrect recipe selection across multiple product lines and manufacturing areas. For example, youre, equipment used for manufacturing gu ®® tablets contains numerous obsolete recipes for the same product code ge including versions (he that are marked obsolete but remain selectable on the Human Machine Interface (HMI) for Additionally, other equipment, such as no contains numerous unauthorized recipes that are selectable during commercial production, including recipes named after specific batches such as OA) (01) Your firm's procedures acknowledge this limitation but do not provide compensating controls to prevent incorrect recipe selection during manufacture of commercial batches. gq machine gq, was recently used to manufacture gq, bw tabye mg batches Ch) This product was shipped for distribution to the US market B. Inadequate Access Controls and User Privilege Management Your user access system combines Quality Assurance personnel with production supervisors under a single user category. Your procedures state that recipe creation should be restricted to Quality Assurance personnel, yet the combined user access structure grants both production supervisors and Quality Assurance personnel identical system privileges on computerized equipment. This arrangement fails to enforce the intended segregation of duties and allows production personnel to perform recipe management functions that should be restricted to Quality Assurance oversight. C. Inadequate Documentation and Verification Your batch manufacturing records fail to consistently document which specific recipes were used during manufacturing operations across your computerized systems. While some equipment operations clearly identify recipe names, other operations show parameter controls without documenting the specific recipe selected from multiple available options. For example, batch © tablets 4, mg) manufactured using recipe-capable, equipment gq fails to identify which specific recipe was selected from multiple available options. In contrast, batches manufactured using non-recipe gq, equipment demonstrate manual parameter documentation including lot-by-lot parameter tables with specific limits and parameter verification comparing set versus recorded values.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3004554612, newest first.
- Form 483, May 2017Inspection ended May 26, 2017 · Posted Jun 5, 2017VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.