Skip to content

Montana Compounding Pharmacy P.C. Form 483, September 2016

FDA issued this Form 483 to Montana Compounding Pharmacy P.C. in Missoula, Montana (FEI 3011412185) at the end of a drug inspection that ended September 20, 2016. It lists 5 observations. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Sep 20, 2016
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
2,675 days after the inspection
Facility
FEI 3011412185
Missoula, Montana

The 5 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Use of non-pharmaceutical grade components

    OBSERVATION 1 Non-pharmaceutical grade components are used in the formulation of non-sterile drug products. Specifically, a [(b)(4)] brand [(b)(4) (b)(4)] lot [illegible] [(b)(4)] is used as a component in non-sterile drug products such as [(b)(4)], oral suspensions, and intranasal drug preparations. This non-pharmaceutical grade [(b)(4)] for drug production is dispensed from a 5-gallon water bottle through a drinking water dispenser spigot in the employee break room. A representative example of non-pharmaceutical grade [(b)(4)] used in the formulation of drugs is [(b)(4)] [(b)(4)] that is given a beyond use date (BUD) of 180 days in ambient storage temperature. [(b)(4)] is intended to be used as a preservative in the formulation of drugs such as Oxytocin nasal spray. Oxytocin nasal spray is assigned BUD of 90 days in refrigeration. This is a repeat observation. b. Non-pharmaceutical grade [(b)(4)] markers are used as a component in non-sterile drug capsule production. After encapsulation of a drug product, a [(b)(4)] marker is applied directly on each capsule to make a distinguished marking. No control is in place to prevent the marker material from penetrating to the drugs.

  2. 2

    Vermin (fly) in production area

    OBSERVATION 2 Vermin was observed in your production area. Specifically, On 8/30/2016, a fly was noted hovering over the in-process drug [(b)(4)] mixture and hovering over the production area during the process and capsule filling of Thyroid USP 16.25 mg capsule, lot 08302016:49@3. This fly was observed directly on a drug container, production work table and lab coat, street pants, hair and face of the operator during production.

  3. 3

    Missing HVAC louver, particulate risk

    OBSERVATION 3 Non-microbial contamination was observed in your production area. Specifically, One section of the dust covered louver blades of the HVAC system was missing over the production area. Uncontrolled airflow from this missing louver section would allow for undesired particulates into uncovered, weighed [(b)(4)] active pharmaceutical ingredients and components for production.

  4. 4

    No dedicated area/cleaning for hazardous drugs

    OBSERVATION 4 Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, There is no dedicated area for production and cleaning of such area prior to drug production. On 8/30 and 8/31/2016, no cleaning of the work surfaces were done prior to the weighing and staging of components and mixing of drug products during the production of Thyroid USP 16.25 mg capsule, lot 08302016:49@3, Estradiol 2 mg Capsule, lot 08302016:15@5. This production work station is a shared space for (b)(4) and (b)(4).

  5. 5

    Unlabeled reusable syringes risk cross-contamination

    OBSERVATION 5 Highly potent drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, An unlabeled and reusable syringe reported to be used multiple times to draw contents from a component [(b)(4)] for production of drug products was observed secured to the container with a rubber band. [(b)(4)] is formulated with non-pharmaceutical grade [(b)(4)]. There was no label on the syringe to prevent a mix-up in using the dispensing aid for different components. There is no control on the number of uses or duration a syringe is used. Securing a syringe to a component, to be re-used to draw contents from the component, is a common practice at the firm as identical syringes were observed to be secured with a rubber band to various containers. This is a repeat observation.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterMay 9, 2018CDER · 596 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3011412185, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.