Skip to content

Diana T. Widicus, M.D.

1118 W Legacy Pointe Dr, Springfield, Illinois, United States

FEI 3042222477

FDA has one inspection on file for Diana T. Widicus, M.D. in Springfield, Illinois (FEI 3042222477). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2026
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Requested under FOIA
1 request, latest Jun 16, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch MonitoringPosted 483 · 1 observation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate accurate case histories for SAEs AEs

      Failure to prepare or maintain adequate and accurate case histories with respect to observations and data pertinent to the investigation. Specifically, 1) Seventeen (17) out of twenty-eight (28) subjects reviewed had inaccurate serious adverse event (SAE) and adverse event (AE) data transcribed from the paper source into the electronic case report form (eCRF). The following are examples of these discrepancies: AE/SAE Description Source Document EDC/Data Listing Subject ID SAE: Metastatic Squamous Cell Carcinoma Start Date: 6/20/2023 Start Date: 6/20/2023 Subject [illegible] SAE: Pathological fracture of spine due to neoplastic disease Start Date: No start date End Date: No end date Start Date: (b)(6), (b)(7)(C) End Date: 12/12/2023 Subject (b)(6), (b)(7)(C) AE: Low magnesium End date: 12/20/2023; No end date; Outcome: Not recovered/not resolved Outcome: Recovered/Resolved Subject AMENDMENT 1 AE: Pain in right foot Outcome: Not recovered/Not resolved Outcome: Recovering/Resolving Subject [illegible] AE: Left shoulder pain Start: 3/16/2023; End: 3/23/2023 Start: 3/23/2023; End: 3/30/2023 Subject [illegible] AE: Low potassium levels End date: 2/4/2022; No end date; Outcome: Recovering/Resolving Outcome: Recovering/Resolving Subject (b)(6), (b)(7)(C) AE: Heartburn End date: 4/9/2021; No end date; Outcome: Not recovered/Not resolved Outcome: Recovered/Resolved Subject (b)(6), (b)(7)(C) AE: Rectal Bleeding End date: 2/18/2025; No end date; Outcome: Not recovered/not resolved Outcome: Recovered/Resolved Subject [illegible] AE: Depression End date: 5/20/2022; No end date; Outcome: Not recovered/not resolved Outcome: Recovered/Resolved Subject (b)(6), (b)(7)(C) AE: Right Lower Back Pain Start date: 2/18/2022 Start date: 2/22/2022 Subject [illegible] AE: Second degree heart block, Mobitz type 1 Outcome: Not recovered/not resolved Outcome: Recovering/Resolving Subject (b)(6), (b)(7)(C) Severity: Moderate Severity: Mild AE: Concussion AE: Lower Respiratory Infection End date: 11/9/2022 End date: 10/19/2022 Subject (b)(6), (b)(7)(C) AE: Upper Respiratory Infection Start date: 1/12/2024 Start date: 1/13/2024 Outcome: Not recovered/Not resolved Outcome: Recovered/Resolved Subject (b)(6), (b)(7)(C) AE: Vomiting [illegible] resolved AE: Shooting pain on face Start Date: 11/24/2015 Start Date: 11/24/2021 Subject (b)(6), (b)(7)(C) AE: Diaphragm injury from cardiac ablation No start date Start Date: (b)(6), (b)(7)(C) Outcome: Not Recovered/Not Resolved Outcome: Incomplete Subject (b)(6), (b)(7)(C) AE: Worsening Back Pain No end date; Outcome: Not recovered/Not resolved End date: 1/27/2025 Outcome: Recovered/Resolved Subject [illegible] AE: Worsening Back Pain Outcome: Recovered/Resolved [illegible] Subject (b)(6), (b)(7)(C) AE: Dizziness when standing up Start date: 5/27/2022 Start date: 2/3/2023 2) End date for SAE related to Kidney Infection for subject (b)(6), (b)(7)(C) was not reported to the sponsor. 3) AE records were not accurately maintained. For instance, four SAEs for subject (b)(6), (b)(7)(C) end dates were initially documented as 2/2/2022. These dates were subsequently crossed out to indicate the SAEs had not ended, with the correction dated 2/2/2022. However, the adverse event form was not initiated until 10/23/2022, approximately 8 months after the documented correction date. 4) The primary efficacy study endpoint, (b)(4) for Subject (b)(6), (b)(7)(C), was missing from the source record.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Jun 16, 2026. It asked for a Form 483.

  • Inspection ending Apr 3, 2026VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jun 16, 2026FDA-FOIA-2026-5831Form 483· 1 of 4 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3042222477 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3042222477. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.