Skip to content

F.H. Investments Inc dba Asteria Health

Alabama

FEI 3038253438

FDA has one inspection on file for F.H. Investments Inc dba Asteria Health in Alabama (FEI 3038253438). It ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 10 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
1, in 2025
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 10 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Lack of process validation and controls

      Your firm failed to establish adequate written procedures to assure that the drug products have identity, strength, purity, and composition as represented to possess. Specifically, Your firm has been manufacturing and distributing implantable hormone pellets [illegible] conducting process validation. Your firm has not [illegible] equipment used for drug production nor has your [illegible] for any of your drug products. Your justification includes legal [illegible] produced and distributed and claims of no changes to equipment, formulation, and materials. However, your firm has made changes to your manufacturing process by, • Adding new equipment (i.e., metal detectors, weight so[illegible] your manufacturing process • Changing drug formulation in the master batch record: [illegible] pharmaceutical ingredient and excipient • Changing the visual inspection and sampling process Your firm was made aware of lack of process validation cited by a third-party audit between September 30, 20[illegible] this as opportunities for improvement. Your manufacturing processes are not in a state [illegible] A. Ongoing metal and foreign material contamination (pellet presses, microcappers, metal detector) and lack of process control and resulting in batch rejections, including: Date Deviation # Metallic shaving 05/27/2025 DV25-035 leading [(6) (4) Metallic shavings 06/27/2025, DV25-041 and~ 07/01/2025 25mg, L Metallic shavings 10/17/2025 DV25-070 and[(] pellet, L Metallic shavings leading to one rejected batch - Testosterone 100mg, Lot 10/24/2025 DV25-077 l(t5) inspection. Translucent shavings leading to 11/17/2025 DV25-079 (6) (4) inspection. 1. In late October 2025 as part of CAPA25-[illegible] However, your firm has since continued [illegible] Testosterone/Anastrozole 100mg/4mg observed to what appears to be metallic [illegible] This was [illegible] material came from your [illegible] status, your firm has yet to determine [illegible] generated from material, pellet press, sieve. 2. Your firm has not properly qualified [illegible] not limited to: Manufacturing Function Equipment Pressing powders into pellets [(15) (4)] Pellet Press Detect metal 6(6)-(4)]) after Metal Detector pellet pressing Vialing and capping pellets Microcapper Your equipment qualification is inadequate as evidenced by: a) Incomplete equipment qualification Operational Qualification (IQ/OQ) for pellet presses, microcappers, and metal detectors. b) Inadequate Operational Qualification: vacuum pressure gauge was calibrated during OQ and before manufacturing use in May 2025. Currently, you lack certification to ensure [illegible] critical for adequate product flow and the shaping [illegible]. Additionally, per CC25-042 you moved pellet press [(b) (4)] and moved pellet press [(b) (4)] requalify pellet presses after their relocation. [illegible] impact to validated state" because "the [illegible] assessment was incorrect as you were [illegible] vacuum pressure gauge requir[ed] c) Inadequate performance qualification: qualification of one of your microcappers [illegible] the products you manufactured to qualify this [illegible] qualification with empty vials without any product. [illegible] manufacturing process where operators [illegible] the vial using the microcapper. B. Multiple Potency and Process Failures include but are not limited to : Date Report Product (lot) Testosterone/Anastrozole 200mg/1 06/30/2025 DV25-042; Rejected hold togeth[er] Testosterone/Anastrozole 60mg/4mg, Lot Rejected for out-of-specification DV25-046; 06/30/2025 potency release testing. OOS25-002; Results: Specification: Estradiol 6mg, Lot [(b) (4)] Rejected for out-of-specification OOS25-003; for potency release testing. 08/19/2025 DV25-052; CC25-041; Potency Result Specification: Estradiol 6mg L 09/04/2025 OOS25-004 Could not perform potency testing due to broken pellet. C. Lack of sterilization validation - you [(b) (4)] validate [(b) (4)] sterilization processes. [illegible] your actual production

      Shortened here; the PDF has the full text.

    2. Observation 2

      Inadequate sterilization validation

      Procedures designed to prevent microbiological contamination do not include adequate validation of the sterilization process. Specifically, Your non-representative dose audits does not provide assurance that products achieve sterility or maintain quality after sterilization, for the following products that were manufactured and released at this facility. Drug Product Strengths Testosterone 12.5mg, 18mg, 25mg, 37.5mg, 50mg, 62.5mg, 87.5mg, 100mg, 200mg, 303mg Estradiol 6mg, 10mg, 12.5mg, 15mg, 18mg, 20mg, 22mg, 25mg, 37.5mg 87.5mg/17.5mcg, Testosterone/100mg/20mcg, Triamcinolone Acetonide 200mg/40mcg 60mg/4mg,75mg/4mg Testosterone/100mg/4mg, Anastrozole 200mg/10mg *Data derived from 001.2Dmg production log for May 2025 to December 2025. **Expiration date is either 365 day[s] [(b) (4)] Your firm relies on sterility data from a non-representative batch (e.g. created by [(b) (4)] [(6) (2)] sterilization dose audits. This non-representative batch approach does not represent your actual production processes, individual product formulations, which may have different sterilization resistance, bioburden, [illegible].

    Show observations 3 to 10
    1. Observation 3

      Quality unit oversight failures

      The responsibilities and procedures applicable to the quality control unit are not in accordance with procedures or not followed. Specifically, A. Your quality unit has failed to ensure appropriate oversight for changes to master batch records. For example, as part of PRO25-035, your firm updated the powder [illegible] Testosterone Anastrozole products. However, your quality unit failed to appropriately review and adjust the weight of [{6} (4)] accordingly, lead[ing to deviations]. [illegible] weighing specifications issued for manufacturing the • Testosterone/Anastrozole 200mg/10mg, Lot [illegible] would not hold together." Your [illegible] in the master batch record lead • Testosterone/Anastrozole 60m [illegible] process potency testing. Your [illegible] in the master batch record lead • Testosterone/Anastrozole 75mg/4mg, Lot [illegible] specifications passing despite the e[rrors]. B. Your quality unit has failed to establish an effective visual inspection program and to qualify operators on identifying defects as evident by: 1. Absence of defect library system to tra[ck] 2. Absence of qualification test sets your firm cannot verify operators possess the necessary [illegible] products. 3. Absence of procedure for identifying [illegible] defect library. C. No documented rationale exists for a sampling size [illegible] batches for example ranging from (o) ( [illegible] pellets. For example, but not limited to: Testosterone 200mg, Lot 251000180, EXP 09/19/2026 (QTY (6) [illegible] • Testosterone 200mg/ Triamcinolone Acetonide 40mcg, Lot [illegible] EXP 09/23/2026 (QTY (b) [illegible] • Estradiol 10mg, Lot 253000162, EXP 09/12/2026 (QTY (6) [illegible] D. Your quality unit has failed to establish an effective CAPA program: Op CAPA# Issue CAPA25-021 Stability study 06/26/2025 Process CAPA25-035 09/30/2025 validation Hold times for in-process CAPA25-039 10/02/2025 powder and pellets Your quality unit characterized these critical [issues] as opportunities for improvement, minimizing fundamental cGMP deficiencies. Despite these outstanding CAPAs for process validation, stability testing, hold time testing for in-process materials and as of December 15, 2025, your firm continues to manufacture and release hormone pellets. E. Your quality unit has failed to establish procedures that: 1. Define user roles and access controls [for] roles and permissions. 2. Govern data review procedures for [illegible] metal detector logs pellet rejects. You [illegible] batch release decision and to investigate contamination events.

    2. Observation 4

      Insufficient contamination investigations

      The quality control unit lacks authority to review, reject, or approve drug products that have occurred and fully investigate errors that have occurred. Specifically, A. Your quality unit failed to investigate the following events: • Rejected Estradiol 6mg, Lot [(o) ] powder during pressing "without opening" • No investigation was conducted investigation (OOS25-004, fail[ed] [illegible]) Two separate contamination events [illegible] • deviation report (DV25-041). [illegible] established process in your dev[ice] contamination events. B. Inadequate investigation of recurring metallic and foreign contamination events: Deviation Date /CAPA DV25-035/ Metallic shavin, 05/27/2025 [(o) (4) CAPA25-016 Metal shavings from pellet presses 06/27/2025, DV25-041/ [(5) (4) 07/01/2025 CAPA25-024 rejected DV25-070/ Metallic sh 10/17/2025 CAPA25-041 [(D) (4) ] DV25-077/ Metallic materials from pellet press 10/24/2025 N/A [(5) (4)] DV25-079/ Translucent shavings from microcapper 11/17/2025 CAPA25-048 [(5) (4)] Your firm has not adequately conducted [illegible] evident by: 1. Continued contamination, metallic contaminant approximately <0.1 mm for Testosterone/Anastrozole 100mg/4mg, Lot 254000114 ma[ nufactured ] from pellet pressing operations using [(b) (4)]. 2. Limited investigation scope: your firm has failed to analyze contamination types or sources, collect photographic evidence, or characterize contaminant properties, instead treating contamination as waste without investigation, despite repeat contamination occurrences over six months and operators identifying contaminants.

    3. Observation 5

      Aseptic area surfaces not cleanable

      Aseptic processing areas are deficient in that wall are not smooth and/or hard surfaces that are easily cleanable. Specifically, On December 4, 2025, the FDA investigator observed that the side [illegible] Press [(6) (4)] is cracked, making the area difficult to decontaminate and clean. Highly potent and hazardous hormone pellets are manufactured [illegible] For example: • Testosterone 200mg, Lot 251000180, EXP 09 [illegible] • Estradiol 10mg, Lot 253000132, EXP 06 [illegible] • Estradiol 12.5mg, Lot 253000130, EXP 06 [illegible]

    4. Observation 6

      Missing dissolution and hardness testing

      Each batch of controlled-release dosage form drug product is not laboratory tested to demonstrate conformance to the specifications for the rate of release. Specifically, Your firm's current release testing program involving weight and potency testing is inadequate to ensure the quality of solid dosage [forms]. Your firm has failed to establish appropriate release testing specifications for hormone pellets, including: • Absence of dissolution testing for batch release to ensure consistent drug release and prevent dose dumping, control batch variability, and quality control • Absence of hardness/friability testing to ensure physical integrity during the intended multi-month implantation period. Your firm has released more than [illegible] batches covered since May 2025 without adequate release testing, failing to ensure that hormone [pellets] meet standards of identity, strength, quality, and purity before distribution to patients.

    5. Observation 7

      No facility-specific stability/expiry data

      Drug products do not bear an expiration date determined by appropriate stability data to assure compliance with applicable standards of identity, strength, quality and purity at the time of use. Specifically, Your firm did not initiate stability studies until December 3, 2025, for implantable products manufactured at this facility. Stability studies should [illegible] the market to support beyond-use dating/expiration dating on your product labels. In the absence of stability data generated from batches manufactured at this facility, you assigned expiration dates for all batches based on legacy data from another facility. Your [illegible] equipment, formulation, materials are inappropriate as : • Environmental conditions including microbial [loads] • Material and people flow during manufacturing may differ • Facility layout, construction, and HVAC systems may differ • Manufacturing process validation may differ Legacy data from different facilities cannot substitute for facility-specific stability data required to support expiration dating and batch release.

    6. Observation 8

      Incomplete laboratory raw data review

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Specifically, Your laboratory manager reviews only printed chromatograms and audit trail data without reviewing raw electronic data. This process does not ensure the accuracy and reliability of analytical results used for batch release decisions. The lack of review of raw data limits the ability to detect data integrity issues and may affect release decisions.

    7. Observation 9

      Data governance and computer control failures

      Appropriate controls are not exercised over computers or related systems so that records are accurate, readily retrievable, and secure. Specifically, During this inspection, FDA investigators observed multiple data governance and document deficiencies affecting the reliability and integrity of data used for batch release. A. Unrestricted analytical system access: chromatography system on December 4, 2025 contained an "Admin" user profile with unrestricted access to [illegible]. Sequence reports since May 2025 show all potency testing under "admin" accounts, compromising data integrity. B. Inadequate batch record and document control: monitoring, sampling, and visual inspection records are accessible for unlimited printing by non-[illegible], lacking date/time stamps, page number, issuance tracking. C. Uncontrolled equipment documentation: logbooks are not bound or controlled, including HPLC maintenance and cleaning documentation, allowing potential alteration or loss of critical data supporting product quality decisions. These data integrity deficiencies compromise data generated since facility operations began in May 2025, and products may not meet specifications and can be distributed for patient use.

    8. Observation 10

      Incomplete batch records and metal detection

      The batch production and control records are deficient in that they do not include the documentation of the accomplishment of each significant step in manufacturing, and processing. Specifically, Your firm implemented metal detection testing approximately in October 2025 for each pellet batch as a corrective measure to identify metal shavings and particles that have been present beginning in June 2025. However, the results of these metal detection tests are not [illegible]. Additionally, when metal contamination is identified, the contaminant is discarded as waste. The lack of metal detection documentation limits the quality unit's capacity to make well-informed batch release decisions. *DATES OF INSPECTION 12/05/2025 (Mon), 12/08/2025 (Mon), 12/09/2025 (Tue), 12/17/2025 (Wed), 12/19/2025 (Fri).

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3038253438 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3038253438. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.