Skip to content

GenoGenix, LLC

2840 Nw 2nd Ave Ste 204, Boca Raton, Florida, United States

FEI 3032144832

FDA has one inspection on file for GenoGenix, LLC in Boca Raton, Florida (FEI 3032144832). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 16 observations from the PDF; they are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2025
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 16 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Aseptic process validation missing

      OBSERVATION 1 Procedures designed to prevent microbiological contamination do not include validation of the process. Specifically, A) On 07/16/2025, we observed three lots within expiry which were all released and distributed: Vials examined L-Glutamine 25 mg/mL 30 mL vial Lot# GG042225-025 Mfg. (b) (4) EXP. 10/21/2025 Alpha Lipoic Acid 25 mg/mL 30 mL vial Lot# GG050525-004 Mfg. (b) (4) EXP. 11/01/2025 Glutathione Preserved 200 mg/mL 30 mL vial Lot# GG071125-002 Mfg. (b) (4) EXP. 10/10/2025 B) On July 14, 2025, during aseptic filling in ISO 5 (BSC) we observed your sterile technician: - Blocking first air to the opened sterile vials while filling the sterile bulk solution into sterile vials. - Rubbing their gloved hands vigorously for about 1 minute. - Manually reaching into a bag of stoppers and stoppering vials with gloved hands. - Transferring a beaker stored in the ISO 8 area to the ISO 5 work area, moving outer surfaces. - Transferring a beaker stored in the ISO 8 area to the ISO 5 work area and contacting inner surfaces, which had been [illegible]. - Placing components within the ISO 5 work area in a manner that could block first air to critical in-process operations. - Performing sterile operations in the ISO 5 hood with exposed skin on their face. - Moving the tubing for filling out and back into the ISO 5 hood without sanitizing the tubing. On (b) (4), your firm manufactured the following respectively: - Ascorbic Acid (Vitamin C) Preservative Free 500 mg/mL 30 mL Multi-Dose Vials Lot# GG071425-002 Mfg. (b) (4) - Bacteriostatic Water Sterile Waste for Dose Vials, Lot# GG071425-004 Mfg. (b) (4) - Bacteriostatic Water Sterile Waste 30 mL Multi-Dose Vials, Lot# GG071425-005 Mfg. (b) (4) C) Your firm has not performed media fills for aseptic operations and releasing sterile drugs from August 2024 to July 2025. D) Your firm has not performed gowning qualifications for personnel manufacturing sterile drugs from August 2024 to July 2025. E) Your firm has not performed any personnel monitoring for any compounding technicians that manufactured sterile drugs from August 2024 to July 2025. F) Your firm has not performed (b) (4) filtered through the [illegible] ISO 5 Biological Safety Cabinets (BSCs). G) Your firm has not performed smoke studies [illegible] for releasing sterile drugs from August 2024 to July 2025. H) Your firm has not qualified any compounding technician for visual [illegible]. From approximately August 2024 to July 2025 your firm manufactured sterile injectable vials, (b) (4) vials, and nasal sprays. Examples of sterile products released include but are not limited to: Aseptically compounded by firm: - L-Glutamine 25 mg/mL 30 mL Multi-Dose Vial - Alpha Lipoic Acid 25 mg/mL 30 mL Multi-Dose Vial - Glutathione Preserved 200 mg/mL 30 mL Multi-Dose Vial - Bacteriostatic Water 10 mL and 30 mL vials Multi-Dose Vial - Ascorbic Acid (Vitamin C) Preservative Free 500 mg/mL 30 mL Multi-Dose Vial Repackaged or Relabeled by firm: - Semaglutide 20-25 mg/10 mL (b) (4) - Tirzepatide 60 mg/10 mL vial (b) (4) - Retatrutide 60 mg/10 mL vial (b) (4) - Thymosin Alpha 1 (TA1) 10 mg/3 mL vial - BPC 157 15 mg, Thymosin Beta-4 15 mg - Mitochondrial Powerhouse PEG-MOTS-c MSC Exosomes (b) (4) 10 mL vial Bei Y. He, Investigator SEE REVERSE OF THIS PAGE Sarah M. Gauna, Investigator

    2. Observation 2

      Quality unit procedures not implemented

      OBSERVATION 2 The responsibilities and procedures applicable to the quality control unit are not followed. Specifically, your firm has manufactured and released drug products without adequate quality unit oversight. A. Your QU has not established control over: - The release specifications of finished drug products for release and distribution. - Recall, reject, and quarantine of drug products held, manufactured, labeled, and/or repackaged at this facility. - Drug products reprocessed and repackaged at this facility. - Changes to drug formulations, components, and manufacturing steps listed on the drug product labels. - Employee training and qualifications. B. Your QU has not implemented sterility assurance for drugs manufactured at this facility, these include but are not limited to: - Contamination control strategies not established. - Environmental monitoring is not established. - Cleaning validations is not established. - Cleaning records are inconsistently recorded or not recorded. - Aseptic process validations - e.g., - Media fill is not established. - Aseptic technician qualification is not established. - Personnel monitoring is not established. - Post aseptic (b) (4) - [illegible]. - Process validation is not established. - Sterility Data - e.g., - Finished product testing is not established. - Stability program is not established. - Container closure integrity testing not established. C. Your QU has not established the following procedures, examples include: - Established master batch record and production batch records - Review and release of drug products - Investigations - Change Controls - Corrective and Preventive actions - Recalls - Quarantine, Reprocess, Reject - Adverse Events and Complaints - Incoming and Release Testing - Inventory Management - Equipment Validation and Qualifications - Product Retains - Stability Study Programs - Document Control and Retention - Data Integrity - Training Program - Aseptic Processes From approximately August 2024 to July 2025 your firm released sterile injectable vials, (b) (4) vials, nasal sprays, and non-sterile products such as capsules and nasal sprays. Examples of sterile products released include but are not limited to: Aseptically compounded: - L-Glutamine 25 mg/mL 30 mL Multi-Dose Vial - Alpha Lipoic Acid 25 mg/mL 30 mL Multi-Dose Vial - Glutathione Preserved 200 mg/mL 30 mL Multi-Dose Vial - Bacteriostatic Water 10 mL and 30 mL vials Multi-Dose Vial - Ascorbic Acid (Vitamin C) Preservative Free 500 mg/mL Repackaged or Relabeled: - Semaglutide 25 mg/10 mL (b) (4) - Tirzepatide 60 mg/10 mL vial (b) (4) - Retatrutide 60 mg/10 mL vial (b) (4) - Thymosin Alpha 1 (TA1) 10 mg/3 mL vial Compounded: - Oxytocin 100 iU/ Methylene Blue 1%/mL - Rapamycin 2.5 mg Capsules Bei Y. He, Investigator Sarah M. Gauna, Investigator

    Show observations 3 to 16
    1. Observation 3

      Failure to investigate OOS and outages

      OBSERVATION 3 There is a failure to thoroughly review any unexplained discrepancy or the failure of a batch to meet any of its specifications whether or not the batch has been already distributed. Specifically, A) Your firm failed to initiate an investigation after a power outage on July 12, 2025, which interrupted the power supplies to your cleanrooms and refrigerators used for product storage. On (b) (4), your firm recommenced sterile manufacturing without performing any sterility impact assessment and determination on the length of time products were exposed. As an example, the following were manufactured on (b) (4): - Ascorbic Acid (Vitamin C) Preservative Free 500 mg/mL 30 mL Lot# GG071425-002, Mfg. (b) (4) - Bacteriostatic Water Sterile Waste for Dose Vials, Lot# GG071425-004, Mfg. (b) (4) - Bacteriostatic Water Sterile waste 30 mL Multi-Dose Vials, Lot# GG071425-005, Mfg. (b) (4) B) Your firm lacks appropriate complaint investigation and root-cause determination, e.g., Your firm initiated complaint investigation QA018-F001 into NAD+ lot GG121624-023 after receiving a notification from a health provider that three patients experienced adverse symptoms (e.g., low blood pressure, uncontrollable shaking, shivers, and body aches) shortly after or while receiving NAD+ infusion. According to the complaint report, three patients received NAD+ Lot# GG121624-023 from the same vial and were directed to the emergency room. As part of your investigation, your firm sent three vials to a testing laboratory for endotoxin and sterility testing and received the following results. Sample Condition NAD 200 mg/mL Intact vial Lot# GG121624-023 NAD 200 mg/mL Lot# GG121624-023 Opened vial NAD 100 mg/mL Lot# GG121624-023 Intact vial GG020425-010 From your investigation, you determined the root-cause of adverse reactions were attributed to the presence of [illegible] in the GG121624-023 formulation. Your firm did not adequately evaluate these endotoxin testing results and impact to patient safety. C) Your firm released reprocessed material from a batch that had been calculated to be super potent in the initially released portion. The reprocessed material met specifications. After recalling half of the batch due to superpotency, you released the remaining reprocessed portion without testing to verify the reprocessed material met specifications. Original batch record was identified as Magnesium Chloride 200 mg/mL Lot# GG043025-001, Mfg. (b) (4), EXP. 10/29/2025. Reprocessed batch was provided Magnesium Chloride 200 mg/mL Lot# GG050225-001, Mfg. (b) (4), EXP. 11/01/2025. D) Your firm has out of specification (OOS) endotoxin and potency test results but failed to initiate corrective and preventive actions (CAPA) for these results. Your firm did not adequately identify root causes or implement corrective and preventive actions including but not limited to the following. Endotoxin Test Result Completed Product (Specification) Date 6.62 EU/mL "Fail" 10.0 mg/mL 06/06/2025 5.08 EU/mL "Fail" 10.0 mg/mL 06/14/2025 10.8 EU/mL "Fail" 10.0 mg/mL 07/10/2025 Potency Test Result Completed Product (specification) Date Tirzepatide 84.4% 03/12/2025 40 mg/vial Tirzepatide 87.5% 03/31/2025 100 mg/vial 65.3% 05/12/2025 (product not fully legible) Methylcobalamin 84.5% 06/03/2025 NAD+ 2 [illegible] 59.4% Zinc S 06/04/2025 (illegible) 43.1% [illegible] 06/09/2025 Your firm did not perform adequate CAPA or investigations for most of these OOS results. Bei Y. He, Investigator Sarah M. Gauna, Investigator

    2. Observation 4

      Environmental and pressure monitoring lacking

      OBSERVATION 4 Aseptic processing areas are deficient regarding the systems and controls necessary to ensure aseptic operations. Specifically, A) Your firm has not performed any environmental monitoring during aseptic operation since you started manufacturing and releasing sterile products. B) Your firm has not performed personnel monitoring during aseptic operations since you started manufacturing and releasing sterile drug products from August 2024 to July 2025. C) Your firm does not perform continuous pressure differential monitoring in your ISO 7 cleanrooms. You only perform pressure differential at [production start points]. Pressure differentials monitored [illegible]. D) Your firm had a power outage sometime during July 2025; your firm has not determined the length of the outage, nor taken appropriate steps to mitigate the issue, for example but not limited to performing any environmental monitoring following cleaning. E) Your firm has no cleaning records for the cleanrooms. The following lots were observed in storage and labeling: NAD 200 mg/mL Lot# GG121624-023; L-Glutamine 25 mg/mL 30 mL vial, Lot# GG042225-025 EXP. 10/21/2025; Alpha Lipoic Acid 25 mg/mL 30 mL vial, Lot# GG050525-004 EXP. 11/01/2025; Glutathione Preserved 200 mg/mL 30 mL vial, Lot# GG071125-002 EXP. 10/10/2025. *** Firm stated there is no manufacturing environmental monitoring program. From approximately August 2024 to July 2025 your firm manufactured sterile injectable vials, (b) (4) vials, and nasal sprays. Examples of products released include but are not limited to: L-Glutamine 25 mg/mL 30 mL Multi-Dose Vial; Alpha Lipoic Acid 25 mg/mL 30 mL; Glutathione Preserved 200 mg/mL 30 mL; Bacteriostatic Water 10 mL and 30 mL; Ascorbic Acid (Vitamin C) Preservative Free 500 mg/mL 30 mL Multi-Dose Vial; Semaglutide 25 mg/10 mL (b) (4); Tirzepatide 60 mg/10 mL vial (b) (4); Retatrutide 60 mg/10 mL vial (b) (4); Thymosin Alpha 1 (TA1) 10 mg/3 mL; Oxytocin 100 iU/ Methylene Blue 1%/mL; Rapamycin 2.5 mg Capsules. Bei Y. He, Investigator Sarah M. Gauna, Investigator

    3. Observation 5

      Required lot testing not performed

      OBSERVATION 5 Laboratory controls do not include the establishment of specifications, standards, sampling plans and test procedures designed to assure that components, containers, closures, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, A) Your firm failed to consistently conduct required testing on manufactured lots. The absence of systematic lot testing compromises batch release procedures and prevents verification that each lot conforms to established specifications before distribution. Lots without documented release testing include: - NAD 200 mg/mL Lot# GG121624-023 - L-Glutamine 25 mg/mL 30 mL vial Lot# GG042225-025, Mfg. (b) (4) EXP. 10/21/2025 - MSC Exosomes Reconstitution Solution 20% MSC Exosomes, 8 mL in a 10 mL Multi-Dose Vial Lot# GG052825-019, Mfg. (b) (4) EXP. 11/12/2025 - Alpha Lipoic Acid 25 mg/mL 30 mL vial Lot# GG050525-004, Mfg. (b) (4) EXP. 11/01/2025 Bei Y. He, Investigator Sarah M. Gauna, Investigator

    4. Observation 6

      Reprocessing controls inadequate

      OBSERVATION 6 Reprocessing procedures lack the steps to be assured reprocessed material will meet all established standards, specifications, and characteristics. Specifically, Your firm did not complete an investigation for released reprocessed material from a batch that had been calculated to be super potent in the initially released portion. Your firm released the remaining reprocessed portion without testing to verify the reprocessed material met specifications. Original batch record was identified as Magnesium Chloride 200 mg/mL Lot# GG043025-001, Mfg. (b) (4), EXP. 10/29/2025. Reprocessed batch was provided, Magnesium Chloride 200 mg/mL Lot# GG050225-001, Mfg. (b) (4), EXP. 11/01/2025. Bei Y. He, Investigator Sarah M. Gauna, Investigator

    5. Observation 7

      Cleanroom construction and cleanliness issues

      OBSERVATION 7 Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations. Specifically, A) Your "Ceiling Cassette" located in the ISO 7 cleanroom lacks HEPA filtration. The absence of HEPA filtration on this unit can introduce airborne particulate contamination into aseptic manufacturing operations. Additionally, the adjacent ISO 8 room has a ceiling-mounted air return. B) The door frame between your ISO 7 cleanroom and adjacent area is constructed of a wood-like material. Wood is porous and can not be adequately cleaned and may not maintain the controlled environment standards required. C) Your cleanroom sliding glass doors have visible gaps that could compromise the integrity of the controlled environment. These openings present potential contamination transfer. Additionally, when the sliding door is open your cleanrooms do not maintain positive pressure. D) Your (b) (4) between the ISO 8 room and ISO 7 "area" room lacks an interlocking mechanism to prevent both doors from being opened simultaneously. E) Each of your cleanrooms have a "Ceiling Cassette" that are not easily cleanable. Additionally, on July 14, 2025, we observed dust-like accumulation on air intake for these units. F) The sliding glass door tracks to ISO 7 and ISO 8 cleanrooms have difficult to clean surfaces, e.g., the wall-mounted tracks contain grooved channels that create crevices and recessed areas that are difficult to clean. G) The caulking to the ISO 7 cleanroom ceiling tiles, wall seams, and door frames are not constructed of smooth and easily cleanable surfaces. H) Your material (b) (4) [illegible] contain residue with visible debris and fibers adhered to the surface. From approximately August 2024 to July 2025 your firm manufactured sterile injectable vials, (b) (4) vials, nasal sprays, and non-sterile products. Examples of sterile products manufactured and released include but are not limited to: L-Glutamine 25 mg/mL 30 mL Multi-Dose Vial; Alpha Lipoic Acid 25 mg/mL 30 mL Multi-Dose Vial; Glutathione Preserved 200 mg/mL 30 mL; Bacteriostatic Water 10 mL and 30 mL vials Multi-Dose Vial; Ascorbic Acid (Vitamin C) Preservative Free 500 mg/mL 30 mL Multi-Dose Vial. Repackaged or Relabeled: - Semaglutide 25 mg/10 mL (b) (4) - Tirzepatide 60 mg/10 mL vial (b) (4) - Retatrutide 60 mg/10 mL vial (b) (4) - Thymosin Alpha 1 (TA1) 10 mg/3 mL vial Bei Y. He, Investigator Sarah M. Gauna, Investigator

    6. Observation 8

      Incoming component testing insufficient

      OBSERVATION 8 Reports of analysis from component suppliers are accepted in lieu of performing identity testing on each component and establishing the reliability and validation of the supplier's test results at appropriate intervals. Specifically, A. Your firm has not: - Performed at least one specific identity test on incoming components; you lack confirmatory testing procedures for incoming components. - Established the reliability of supplier analyses through appropriate validation of supplier results at defined intervals. - Established process for testing active pharmaceutical ingredients (APIs) upon receipt. From approximately August 2024 to July 2025 your firm manufactured sterile injectable vials, (b) (4) vials, and nasal sprays. Examples of sterile products manufactured include: L-Glutamine 25 mg/mL 30 mL Multi-Dose Vial; Alpha Lipoic Acid 25 mg/mL 30 mL Multi-Dose Vial; Glutathione Preserved 200 mg/mL 30 mL Multi-Dose Vial; Bacteriostatic Water 10 mL and 30 mL vials Multi-Dose Vial; Ascorbic Acid (Vitamin C) Preservative Free 500 mg/mL 30 mL Multi-Dose Vial. B. Your firm receives finished (b) (4) products without performing required identity testing or establishing supplier reliability. Specifically, your firm received products including: - Semaglutide 20 mg - Tirzepatide 20 mg - Retatrutide 60 mg - Thymosin Alpha-1 10 mg Your firm then relabels and releases these products without confirmatory testing. Certificates of analysis lack manufacturer identification, and your receiving records do not document supplier addresses. This practice fails to ensure product identity and quality prior to distribution. Bei Y. He, Investigator Sarah M. Gauna, Investigator

    7. Observation 9

      Incomplete batch and distribution records

      OBSERVATION 9 Batch production and control records are not prepared in adequate detail and do not include complete information relating to the production and control of each batch. Specifically, A) Your firm has not provided complete distribution records. When requested during the inspection, you were unable to provide distribution records containing the required elements (product name, strength, dosage form, recipient name and address, date, quantity shipped) for drug products distributed from January 2024 to July 2025. This failure compromises your ability to conduct effective recalls and maintain proper traceability. B) Your firm only started documenting and using draft batch records in May 2025. You have batch records for the following: - L-Glutamine 25 mg/mL 30 mL vial Lot# GG042225-025 Mfg. (b) (4) EXP. 10/21/2025. Additionally, during inspection you observed contaminants in this lot. - MSC Exosomes Reconstitution Solution 20% MSC Exosomes, per vial 8 mL in a 10 mL Multi-Dose Vial Lot# GG052825-019, Mfg. (b) (4) EXP. 11/12/2025 - NAD 200 mg/mL Lot# GG121624-023 Bei Y. He, Investigator Sarah M. Gauna, Investigator

    8. Observation 10

      Label control and security inadequate

      OBSERVATION 10 Strict control is not exercised over labeling issued for use. Specifically, A. On July 14, 2025, we observed five pre-printed and unsecured labels stored in the finished product refrigerator. The following information is listed on the labels: "Capsules" "For Research Purposes Only" "Manufactured for [illegible] USA" "LOT: GG070225-001" "MFG: (b) (4)". B. Your batch record for Glutathione Preserved 200 mg/mL 30 mL Multi-Dose Vial Mfg. (b) (4) EXP. 10/01/2025 has labeling that does not match the batch record. The product is labeled as Glutathione Preserved 200 mg/mL 30 mL Multi-Dose Vial and does not include the (b) (4) listed on the batch record. This lot was labeled and released for distribution the same day. Product shipping records show this lot was distributed starting 7/14/2025. Bei Y. He, Investigator Sarah M. Gauna, Investigator

    9. Observation 11

      Visual inspection for particulates missing

      OBSERVATION 11 Control procedures are not established which provide assurance that procedures are in place for causing variability in the characteristics of the drug product. Specifically, Your firm does not perform 100% visual inspection for particulate matter on sterile drug products packaged in amber vials, nor does your firm perform appropriate visual inspection as required by your batch records. For example: Batch Record Document Number (b) (4) Lot# GG050525-004, manufactured on (b) (4): - Step 5.2 states: "Perform Visual Inspection on all finished product bottles/vials. For amber vials or opaque or translucent vials/containers, inspect for container integrity. For clear vials or containers, inspect for container integrity and product particulates." - Step 5.2.3 indicated that all vials passed 100% visual inspection; however, your actual practice does not include particulate inspection for amber vials. Batch Record Document Number (b) (4) vials, Lot Number GG071125-002, manufactured on (b) (4): - Step 8.2 states: "Perform Visual Inspection on all finished product bottles/vials. For amber vials or opaque or translucent vials/containers, inspect for container integrity. For clear vials or containers, inspect for container integrity and product particulates." - Step 8.2.3 indicated that all vials passed 100% visual inspection; however, your actual practice does not include particulate inspection for amber vials. L-Glutamine 25 mg/mL 30 mL vial Lot# GG042225-025, EXP. 10/21/2025, manufactured on (b) (4). - While your firm asserts that "a basic visual inspection" is performed, you do not have documentation to demonstrate that this lot was properly inspected prior to release. - Furthermore, on July 17, 2025 we visually inspected all vials of this lot held in your inventory and observed contaminants in all inspected vials. Bei Y. He, Investigator Sarah M. Gauna, Investigator

    10. Observation 12

      Personnel training records missing

      OBSERVATION 12 Employees engaged in the manufacture, processing, packing and holding of drug products lack the education, training and experience required to perform their assigned functions. Specifically, Your firm failed to provide documentation of training and qualifications for employees involved in sterile processing operations. Bei Y. He, Investigator

    11. Observation 13

      Required label information missing

      OBSERVATION 13 The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act). Specifically, A. The labels for some of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A). Specifically, the following information is not found on drug product labels: - The established name of the drug. Examples of your drug product labels that do not include this information include but are not limited to: Rapamycin 2.5 mg caps, Clear Mind 150 (NAD+ 150 mg/mL) Nasal Spray, LIPO (MIC) + B Multi-dose Vial. - The dosage form. Examples of your drug product labels that do not include this information include but are not limited to: LIPO (MIC) + B Multi-dose Vial. - A list of active and inactive ingredients, identified by established name and the quantity or proportion of each ingredient. Examples of your drug product labels that do not include this information include but are not limited to: Rapamycin 2.5 mg caps. Bei Y. He, Investigator Sarah M. Gauna, Investigator

    12. Observation 14

      Container labels lack required information

      OBSERVATION 14 The containers of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act). Specifically, A. The containers of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(B). Specifically, your containers do not include the following information: - Information to facilitate adverse event reporting per FDA-1088. Examples of your container labels that do not contain this information include: Immune Defense Nasal Spray. - Directions for use, including dosage and administration. Examples of container labels that do not contain this information include: Immune Defense Nasal Spray. Bei Y. He, Investigator Sarah M. Gauna, Investigator

    13. Observation 15

      Use of ineligible bulk drug substances

      OBSERVATION 15 Your outsourcing facility compounds drug products using bulk drug substances that are ineligible for compounding under section 503B of the Federal Food, Drug, and Cosmetic Act because they (a) are not used to compound drug products that appear on the shortage list developed under section 506E of the Act and (b) do not appear on a list developed by FDA of bulk drug substances for which there is a clinical need. Specifically, You produce and distribute drug products containing bulk drug substances that are ineligible for use in human drug compounding, including but not limited to [(b) (4)]. Bei Y. He, Investigator Sarah M. Gauna, Investigator

    14. Observation 16

      Required FDA product report not submitted

      OBSERVATION 16 Your outsourcing facility has not submitted a report to FDA identifying a product compounded during the previous six months as required by section 503B(b)(2)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act). Specifically, Your outsourcing facility did not submit a report to FDA for the previous six-month period. Specifically, you did not submit the required initial product report and the required biannual product report for June 2025. DATES OF INSPECTION 07/14/2025 (Mon), 07/15/2025 (Tue), 07/16/2025 (Wed), 07/17/2025 (Thu), 07/18/2025 (Fri) Bei Y. He, Investigator Sarah M. Gauna, Investigator

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3032144832 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3032144832. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.