Skip to content

Sentara Enterprises

920 E High St, Charlottesville, Virginia, United States

FEI 3025984445

FDA has one inspection on file for Sentara Enterprises in Charlottesville, Virginia (FEI 3025984445). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published 5 citations from this inspection. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2023
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Inadequate smoke studies

      Smoke studies were inadequately performed under dynamic conditions.

    2. FDCA 501(a)(2)(A)

      Personnel exposure during aseptic manipulations

      Personnel performed aseptic manipulations with exposed hair or skin.

    3. FDCA 501(a)(2)(A)

      Personnel, blocked or disrupted first air

      Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted.

    4. FDCA 501(a)(2)(A)

      Lack of disinfection, equipment/supplies from lower to higher quality air

      Lack of disinfection of supplies at each transition from areas of lower quality air to areas of higher quality air.

    5. FDCA 501(a)(2)(A)

      Media fills, failure

      Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3025984445 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3025984445. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.