Prof. Bernardo Leon Rapaport
129 Oxford Road, Johannesburg, South Africa
FEI 3021927419
FDA has 2 inspections on file for Prof. Bernardo Leon Rapaport in Johannesburg, South Africa (FEI 3021927419), from 2022 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2022–2026
- 0 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 2
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 2 requests, latest May 8, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch MonitoringPosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Protocol dosing and administration deviations
OBSERVATION 1 An investigation was not conducted in accordance with the investigational plan. Specifically, Your study site failed to follow the protocol and pharmacy manual instructions with respect to proper dosage and administration of the investigational product (IP). A. The Pharmacy Manual utilized for both (®)) and (04) studies require to be diluted to achieve a final concentration range of 1.1mg/mL to 3.4mg/mL. 2 of 8 (25%) subjects enrolled into (®)@) and 3 of 11 (27%) subjects enrolled into (©) received at least one dose that is above the allowed concentration levels: - Dose Concentration Study Subject Visit Number Administered to Subject Number (a) — mg/mL) RN (aX) C1D1 4.255 C1D8 4.255 C2D1 4.255 [illegible entries in table continued] Subject (®)(6) had a grade 3 adverse event of abnormal kidney functions 3 days after C1D1. b Subject (®)(8) had a grade 3 diarrhea adverse event 2 days after C1D1 as well as a grade 2 skin rash adverse event 6 days after C1D1, requiring dose interruption. B. Both study protocols specify that the first IV infusion should be administered over 3 hours, with subsequent infusions administered over 1 to 2 hours if previous infusions were well tolerated. 3 of 11 subjects (27%) enrolled into (®)@) received B1 infusions in less than the minimum duration required for subsequent infusions: a Duration (b) (6) 2 hours: 1100-1300, later changed to C1D1 24 Aug 2023 3 hours 1100-1400 on 11 Sep 2023. 60-120 [30 minutes: 1235-1305, later changed to C5D8 18 May 2023 [illegible]. 60-120 130 minutes: Original start time is 1047-1117; later changed to 1057-1127 at an unknown date. ® C4D1 29 Jun 2023 60-120 130 minutes: 1047-1117. C5D8 29 Jun 2023 60-120 130 minutes: 1150-1220 minutes * subject (®)(6) C5D8 and Subject (®)(8) C4D1 both occurred on 29 Jun 2023 and feature identical (B) infusion times prior to the undated and unattributed correction to Subject (®) C5D8's infusion record C. The (®) @ study protocol requires that patients be monitored "during, and for at least 30 minutes after infusion" of (®)4). The protocol also specifies that (©) is to be administered "on Day 1 of 21-day cycles." i. For 3 of the 11 (27%) subjects enrolled into (®)@, there was at least one visit where this monitoring period was not observed after, a administration was complete before beginning (®)®) administration. Three of these instances happened on C1D1, the subjects’ first exposure to (b) Subject [==] Observation Period Between Infusions C1D1® Overlapping Administration © Note: Subject (®)(8) C1D1 shows BA) starting prior to completion of © infusion. ii. Subject (®)(6) received (®)@) doses only 7 days apart within the same cycle: C6D1 dated 03 Jul 2024 and C6D8 dated 09 Jul 2024. D. The Pharmacy Manual used for both studies states: "Calculate the prescribed dose in mg based on the subject's body weight at Cycle 1, Day 1 (C1D1). The dose is to remain constant throughout the study unless there is a >10% change in body weight from C1D1. Modifications to the study drug doses administered should be made for a > 10% change in body weight from C1D1 and according to local and regional prescribing standards. Dose modifications for changes in body weight < 10% may be made according to local institutional guidelines." Both study protocols state: "The dose of o will be calculated based on actual weight at [enrollment/randomization] (using weight obtained either at screening or on C1D1) and remains constant throughout the study, unless there is a > 10% change in body weight from baseline. Modifications to the study treatment doses administered should be made for a > 10% change in body weight from baseline and according to local and regional prescribing standards. Dose modifications for changes in body weight < 10% may be made according to local institutional guidelines." Your site routinely changed the reference weight used for o dose calculations in a manner inconsistent with the protocol and pharmacy manual requirements. In my r
Shortened here; the PDF has the full text.
- Observation 2
Inadequate or altered case histories
OBSERVATION 2 Failure to prepare or maintain adequate and accurate case histories with respect to observations and data pertinent to the investigation. Specifically, A. Modifications were made to IP preparation documentation for the dilution volume for 0 dosing. The original value would result in a dose concentration outside of the protocol-specified range of 1.1 mg/mL to 3.4 mg/mL. Many of these were not attributable to a person or date, as there was no initials or dates documented by the changes. Study Subject Visit Apparent Original (4) concentration Attributable? C1D1 4.12 mg/mL [No] C1D8 4.12 mg/mL [No] C2D1 4.12 mg/mL [No] C2D1 4.00 mg/mL [No] C2D1 3.885 mg/mL [No] [illegible entries where original entry obscured] Subject (®)(6) C1D8 (01 Aug 2023) occurred on the same day as Subject (®)(6) C1D1 visit, which had a confirmed overconcentration of [illegible]. Subject (®)(B) C2D1 dose prepared but not administered due to subject experiencing a hypoglycemic event prior to administration, so C2D1 was repeated. During Subject (B)(6)'s C2D1 infusion, she felt hot and developed a rash and the dose was interrupted. A subject, (©) discontinued treatment after C2D8, as more than 3 weeks had elapsed between C1D8 and C2D1 due to adverse events/toxicities, which met protocol stopping criteria for study treatment. Subject (®)(B) C11 is a confirmed overconcentration of [illegible] with a dose of 777 mg and a total dilution volume of 200 mL. Refer to Observation 1, sub-item B. B. Source records related to administration of IP to study subjects has discrepant information or implausible timepoints, were changed without justification, and/or are missing pertinent information: Visit or Visit An initial infusion form was completed with pre-dose vitals, but no infusion documentation. The form states that no adverse events or interruptions/delays occurred during infusions. A new infusion form was generated for this date, also dated 03 Jul 2024. Original infusion card completed through to post-dose vitals with times entered 1035-1105, flush from 1137-1132, and post-dose vitals at 1137. C4D1 03 Apr 2024 The changes to this document state the infusion was 1035-1135, flush 1137-1207, and post-dose vitals at 1215. Infusion record does not indicate what product is infused at this visit. Infusion times originally written as C4D8 06 Apr 2023 1300-1330 with post dose vitals taken at 1400; corrected to 1300-1400 and post-dose vitals at 1430. Original complete infusion record states administered 1125-1225 and flush from 1226-1256 with no [illegible] post dose vitals at 1300. C7D8 30 Jul 2024 [A new infusion document was made and signed 22 Aug 2024 that includes [illegible] administration and was signed 22 Aug 2024 but dated 30 Jul 2024.] Doctor signed off on prescription at 1052 and IP mixing time is stated as 1058; infusion record states that infusion started at 1020 before both of those signoffs. Infusion record updated almost 5 months later to change infusion from 30 minutes (1235-1305) to 60 minutes (1235-1335). Post-dose vital time stated to be 1310, which contradicts the changes. Changes made to this infusion with no date of correction; changes still indicate B administered over improper duration of 30 minutes. C5D8 29 Jun 2023 Changes still indicate B administered over improper duration of 30 minutes. C1D1 25 Oct 2023 Visit records state the IP was not handed over for infusion until 1315; infusion record states infusion began at 1310. Visit records state the IP was not handed over for 29 Jun 2023 infusion until 1050, while infusion records state the infusion began at 1047. Corrections were made to change the handover time to a time of 1043. Post-dose vitals stated to occur at 6; this is in the middle of stated infusion times of [illegible]. C4D1 20 Dec 2023 Original infusion record entry stated infusion from 1050-1250 and [illegible] from 1322-1352, with post dose vitals done 1303, in the middle of the infusions. The infusion document was change
Shortened here; the PDF has the full text.
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on May 8, 2026.
Inspection ending Jul 14, 2022NAI
1 request. In the inspection history above. FDA released records in answer to a request for its Inspection records on May 29, 2026. FDAgent holds no copy that FDA posted.
- May 8, 2026FDA-FOIA-2026-4723Inspection records· 1 of 3 sitesRecords released
Inspection date not given
1 request. FDA released records in answer to a request for its Form 483 on Apr 16, 2026. FDAgent holds no copy that FDA posted.
- Apr 1, 2026FDA-FOIA-2026-3207Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3021927419 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3021927419. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.