Skip to content

Lentigen Technology Inc.

Maryland, USA

FEI 3017812890

FDA has one inspection on file for Lentigen Technology Inc. in Maryland (FEI 3017812890). It ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
1, in 2026
Inspections with 483 observations shown
1 of 1
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
1 request, latest Aug 25, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 1 observation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Incomplete bioburden excursion risk assessment

      Discrepancies involving bioburden excursions are not always fully evaluated. LTI-MSAT 000024, Version 0.2, "Risk Assessment of Lentiviral Production Process Controls for Microbial Contamination", approved on 16 May 2025, and effective on 19 May 2025, is deficient in the evaluation of microbial contamination event(s) which occurred during the manufacture of lentiviral products for commercial use, including root causes and actions taken for correction, prevention and eradication. The risk assessment did not include the evaluation of the Out of Specification (OOS) ISSUE-2025-000084 initiated on 25 Apr 2025. This OOS addressed a bioburden excursion of (b) (4) in the (b) (4) of MAGE-A4-c1032 lentiviral vector (b) (4) batch number (b) (4) collected on (b) (4). The organism identified in this OOS sample was (b) (4) which was also identified in (b) (4) samples taken from other purification steps on the (b) (4). MAGE-A4-c1032 lentiviral vector is used for further manufacture of afamitresgene autoleucel drug product.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Aug 25, 2026. It asked for a Form 483.

  • Inspection ending Jun 24, 2026Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Aug 25, 2026FDA-FOIA-2026-8229Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3017812890 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3017812890. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.