PALMETTO ISOTOPES, LLC
95 Bees Creek Rd, Ridgeland, South Carolina, United States
FEI 3016492204
FDA has one inspection on file for PALMETTO ISOTOPES, LLC in Ridgeland, South Carolina (FEI 3016492204). It ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 6 citations from this inspection. They are listed below. One of the two FOIA requests for this site asked FDA for the 483 from a later inspection, ending Aug 14, 2025, that FDA's Data Dashboard doesn't list yet.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2025
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 2 requests, latest Oct 15, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Production areas, difficult to clean/particle generating
Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces.
- FDCA 501(a)(2)(A)
Personnel in aseptic processing, non-sterile gloves
Personnel engaged in aseptic processing were observed wearing non-sterile gloves.
- FDCA 501(a)(2)(A)
Sporicidal agent, ISO 5/classified areas
Use of a sporicidal agent in the facility's classified areas was improper.
- FDCA 501(a)(2)(A)
Lack of/inadequate, environmental monitoring
Inadequate routine environmental monitoring in the ISO 5 area.
- FDCA 501(a)(2)(A)
Media fills, failure
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.
Show 1 more citation
- FDCA 501(a)(2)(A)
Inadequate smoke studies
Smoke studies were not performed under dynamic conditions.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Oct 15, 2025. Each one asked for a Form 483.
Inspection ending Aug 14, 2025
1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.
- Aug 14, 2025FDA-FOIA-2025-9870Form 483 + EIRWithdrawn
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Oct 15, 2025FDA-FOIA-2025-11899Form 483 + EIRWithdrawn
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3016492204 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3016492204. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.