Liveyon Labs Inc
22667 Old Canal Rd, Yorba Linda, California, United States
FEI 3015381220
FDA has one inspection on file for Liveyon Labs Inc in Yorba Linda, California (FEI 3015381220). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CBER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 9 citations from this inspection: 6 under 21 CFR Part 211, the manufacturing rules for finished drugs, and 3 under 21 CFR Part 1271, the rules for human cell and tissue products. They are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2019
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- · CBER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Blood and Blood ProductsPosted 483 · 9 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Risk factors, clinical evidence
Donors were not screened by a review of relevant medical records for risk factors of communicable disease agents and diseases.
Determination based on screening and testing
HCT/P donors were not determined to be eligible based on the results of donor screening and testing.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Show 4 more citations
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written and followed.
SOP for release; reactive for CMV
A standard operating procedure for the release of HCT/Ps from donors that test reactive for cytomegalovirus (CMV) was not established, maintained, defined and documented.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include validation of the aseptic process.
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.137Expiration dating1 of 1
- 21 CFR 211.192Production record review1 of 1
- 21 CFR 211.198Complaint files1 of 1
- 21 CFR 1271.50How do I determine whether a donor is eligible?1 of 1
- 21 CFR 1271.75How do I screen a donor?1 of 1
- 21 CFR 1271.85What donor testing is required for different types of cells and tissues?1 of 1
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCBER · BiologicsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3015381220 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3015381220. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.