BPI Labs, LLC
Largo, Florida, United States
FEI 3015156709DUNS 119133963
FDA has 3 inspections on file for BPI Labs, LLC in Largo, Florida (FEI 3015156709), from 2025 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below. Two of the seven FOIA requests for this site have asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for packing, through Dec 31, 2027. Its registrant is BPI Labs LLC (D-U-N-S 078627620).
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 3, 2025–2026
- 0 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 3
- 1 posted 483 not matched to an inspection
- Requested under FOIA
- 7 requests, latest Oct 17, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetClassification not posted yetoutsourcing facilityPosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Use of nonpermitted bulk drugs
Your outsourcing facility compounds drug products using bulk drug substances that can compounding under section 503B of the Federal Food, Drug, a they (a) are not used to compound drug products that appear on the section 506E of the Act and (b) do not appear on a list developed by FDA which there is a clinical need. Specifically, Your facility compounded human drug products using tirzepatide bulk
- Observation 2
Quality unit procedures not followed
The responsibilities and procedures applicable to the quality control unit were not followed. Specifically, A. Your firm failed to conduct a media fill for, but not limited to, vial size, fill volume, number. i. Your firm failed to assess the processing run speed and (b)(4) (Line ...) during a media fill to simulate true production conditions. For example, the fill volume for the (b)(4) vials, with a fill volume of 3 mL, Liraglutide Injection, 18 mg/3 mL (6 mg/mL), Batch I846I002Al (BUD 08/15/2026) produced on Line (b)(4) vials, with a fill volume of 3 mL ... minutes. This does not simulate worst case conditions to represent the released sterile drug product. ii. Your firm failed to assess the vial size, production conditions. On Line (b)(4) only (b)(4) vials (Total Batch Size of (b)(4) vials) performed media fills for other vial types. This does not simulate worst case conditions for the larger vial size representing actual sterile drug product produced. a. For 10R vial size filled with 5 mL of Testosterone Cypionate Injection, USP 1000 mg/5 mL (200 mg/mL), Batch I850H001A1 (BUD 10/09/2026, Total Batch Size: (15) (b)(4) vials) produced on (b)(4) ... hours and ... minutes. b. For 10R vial size filled with 5 mL of Testosterone Cypionate Injection, USP 1000 mg/5 mL (200 mg/mL), Batch I85... ((b)(4) vials) produced on (b)(4) ... hours and ... minutes. c. For 4R vial size filled with 5 mL ... 11/01/2026, Total Batch Size: ... with a total ... mg/mL. iii. Your firm failed to assess the number of vials run (b)(4) (Line ...) during a 6 ... initial media fills using approximately ... not simulate true production conditions. For the sterile drug product produced on Line (b)(4) with a fill volume of 3 mL, Tirzepatide and Pyridoxine H ... mg/mL and 30 mg/3 mL (10 mg/mL), Batch I842I002Al ... iv. Additionally, all media fills representing the worst-case scenario on each (15) (b)(4) line were not performed. The firm produced sterile drug without having (b)(4) time frame. For example, Liraglutide Injection, 18 mg/3 mL (6 mg/mL), Batch I846I002Al (BUD 08/15/2026) was produced on (b)(4) and the media fill was performed in April 2025; For Testosterone Cypionate Injection, USP 1000 mg/5 mL (200 mg/mL), Batch I85... (BUD 10/04/26) the media fill was performed on (b)(4); and Pyridoxine Hydrochloride Injection, 60 mg/3 mL (20 mg/mL), Batch I842I002Al (BUD 02/17/2027), was produced on (b)(4) and the media fill was performed in June 2025. There is no assurance that your firm can aseptically produce sterile drug products within your facility. B. Your firm's visual inspection process governed by SOP IPD-026 Visual Inspection (Revision No. 9, effective 03 October 2025) is silent on the requirement of the identification of any critical and major particulates found during the visual inspection process, which could lead to inadequate root cause investigations. C. Your firm performed visual inspection using sterile drug products produced and packaged in clear vials and accepted false rejects or ejects rate of (b)(4) %. However, you did not provide justification for this reject rate for sterile drug products, such as Tirzepatide Injection, 60 mg/3 mL (20 mg/mL) and 30 mg/3 mL (10 mg/mL) Batch I842I002Al (BUD 02/12/2027, Batch Size (b)(4) vials). Your firm accepted false rejected vials (ejected by the visual inspection) and found acceptable through 200% visual inspection for further processing without adequate verification and approval by Quality that these units meet established defect specifications. For Tirzepatide and Pyridoxine Hydrochloride Injection, 60 mg/3 mL (20 mg/mL) and 30 mg/3 mL (10 mg/mL) Batch I842I002Al (BUD 02/12/2027) approximately (b)(4) rejected vials were placed with accepted vials for further processing. This practice compromises the integrity of your visual inspection process and provides no assurance that finished products are free from defects. D. From January to November 2025, nine incidents were investigated for false reject rate
Shortened here; the PDF has the full text.
Show observations 3 to 4
- Observation 3
Inadequate written stability testing
The written stability program for drug products does not include reliable, meaningful analytical methods. Specifically, Your firm failed to establish and follow an adequate written testing program designed to assess impurities profiles for Pyridoxine Hydrochloride used in the Tirzepatide and Pyridoxine Hydrochloride Injection, as outlined in SOP IQC-002 Stability Program. The drug strengths for Tirzepatide and Pyridoxine Hydrochloride Injection produced and released by your firm include the following: Product Code Drug Product Strength 30 mg/3 mL and 30 mg/3 mL (b)(4) 10 mg/mL and 10 mg/mL 60 mg/3 mL and 30 mg/3 mL 40 mg/4 mL and 40 mg/4 mL 40 mg/2 mL and 20 mg/2 mL 20 mg/2 mL and 20 mg/2 mL 68 mg/4 mL and 40 mg/4 mL
- Observation 4
Cleaning verification and swabbing missing
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, Your firm's major cleaning performed for Testosterone Cypionate Injection, USP, drug products failed to include swabbing analysis to verify that the cleaning was adequate prior to the start of subsequent production. For example, Line (b)(4) was used to produce Testosterone Cypionate Injection, USP 2000 mg/10 mL Batch I8611001A (I150H001A) on 10/20/2025 and then underwent major cleaning on 10/23/2025, but no swab samples were collected and analyzed to verify removal of Testosterone residues before Line (b)(4) was released for use in the production of Tirzepatide and Pyridoxine Hydrochloride Injection, 60 mg/3 mL (20 mg/mL) and 30 mg/3 mL (10 mg/mL) Batch I842H007B. Without analytical verification of cleaning effectiveness, there is no assurance that Testosterone residues have been adequately removed to prevent cross-contamination of subsequent batches.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch Monitoring1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 505-1(f)(3)(A)
Failure to comply with REMS Elements to Assure Safe Use (ETASU) A
An application holder did not ensure mechanisms are in place that allow healthcare providers (HCPs) the ability to complete the certification process, as required by your approved REMS Element to Assure Safe Use (ETASU) A.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssurancePosted 483 · 1 citation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 503B(a)(10)(A)
Drug product labels, fails to include
The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Seven requests to FDA under the Freedom of Information Act named this site, most recently on Oct 17, 2026.
Inspection ending Apr 17, 2026Not classified yet
2 requests. In the inspection history above. FDA has posted its Form 483.
- Oct 17, 2026FDA-FOIA-2026-10114Form 483· 1 of 5 sitesOpen
- Apr 29, 2026FDA-FOIA-2026-4248Form 483· 1 of 2 sitesNot a Proper FOIA Request
Inspection ending Apr 23, 2025VAI
3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 23, 2025. FDAgent holds no copy that FDA posted.
- May 14, 2026FDA-FOIA-2026-4942Form 483· 1 of 5 sitesWithdrawn
- Jun 30, 2025FDA-FOIA-2025-8109Form 483· 1 of 5 sitesRecords released
- May 16, 2025FDA-FOIA-2025-4498Form 483· 1 of 8 sitesRecords released
Inspection ending Feb 21, 2025NAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jun 20, 2025FDA-FOIA-2025-7864Form 483· 1 of 10 sitesRecords released
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Oct 1, 2024FDA-FOIA-2024-8529Inspection recordsClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Packing
- Registration runs through
- Dec 31, 2027
- Registrant
- BPI Labs LLCD-U-N-S 078627620
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3015156709 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3015156709. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.