Skip to content

Medscript Compounding Pharmacy

14450 Getz Rd Ste 200, Noblesville, Indiana, United States

FEI 3015147067

FDA has one inspection on file for Medscript Compounding Pharmacy in Noblesville, Indiana (FEI 3015147067). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2019
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate response to microbial contamination

      You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production. Specifically, during environmental sampling of classified cleanroom suites on 05/30/2019, the following were recovered from ISO 5 laminar flow hoods: - 1 cfu/m3 during fungal air testing, identified as Geotrichum sp. at [illegible], referring to the hood on the (15) (4) - 1 cfu on a fungal contact plate, identified as a non-sporulating fungus at [illegible], referring to the hood on the 6 4 Several of your employees verbally confirmed that a retrospective investigation into potentially affected lots made in these hoods was not performed.

    2. Observation 2

      Uncalibrated pressure/gauge testing used

      (15) (4) testing to the 6 4 was not performed. Specifically, the gauge used to measure pressure on the (5) (4) tester was last calibrated on 10/26/2017. We observed this gauge being used during a D 4 test of a b 4 used during production of lot number 07082019%383@3, product ESC01: epinephrine HCl (PF/SF)/lidocaine HCl (PF) in BSS 0.025%/0.75%.

    Show observations 3 to 4
    1. Observation 3

      Materials not disinfected before entry

      Materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, a. Sterile lint-free wipes are stored outside the ISO 5 laminar flow hood, on top of the hood. These wipes are exposed to the ISO 7 environment. During production on 07/08/2019, these wipes were placed inside the ISO 5 laminar flow hood without being sprayed with sterile [illegible] and sterile syringes were placed on top of these wipes. b. During production of several batches on 07/09/2019, the Pharmacy Technician transferring materials to the cart in the material entry room sprayed various materials with sterile [illegible] but did not cover all surfaces with [illegible]. Materials include vials of sterile [illegible], individually-wrapped needles, and individually-wrapped sterile [illegible] wipes. The cart containing these materials were carted into Suite [illegible] (ISO 7) and the materials were transferred into the ISO 5 laminar flow hood and used in production.

    2. Observation 4

      ISO-5 not certified under dynamic conditions

      ISO-5 classified areas were not certified under dynamic conditions. Specifically, uni-directional airflow was not verified under operational conditions. Your firm's Pharmacist-in-Charge reported that when recertification of the cleanrooms was performed on or around [illegible], dynamic conditions were simulated by the recertification company employees by moving their hands inside the hood and walking around the room.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3015147067 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3015147067. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.