ModernaTX, Inc.
One Moderna Way, Norwood, Massachusetts, United States
FEI 3014937058DUNS 116912313
Company: Moderna US, Inc. · Linked by exact D-U-N-S match (117626450) in FDA registration data
FDA has 2 inspections on file for ModernaTX, Inc. in Norwood, Massachusetts (FEI 3014937058), from 2023 to 2024. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant, Moderna US, Inc. (D-U-N-S 117626450), has registered 1 other site.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 2, 2023–2024
- 0 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 2
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 4 requests, latest Sep 23, 2024
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsPosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate equipment cleaning verification
OBSERVATION 1: Equipment utilized for drug substance manufacturing are not cleaned properly prior to its usage. Specifically, your firm does not ensure that the equipment used for drug substance manufacturing are appropriately cleaned prior to the manufacturing of mRNA-1273 drug substance. Your written procedure, SOP-0417, version 10, effective on 01Dec2021 through the current version 16.0, effective on 10Jun2023, entitled as "Manufacturing Room Product Changeover - Norwood" allows the release of manufacturing equipment without confirming the cleaning verification test results for bioburden and endotoxin prior to the usage for subsequent batch manufacturing. Your firm has identified bioburden failures on cleaning verification samples collected from Equipment ID# MIX-1805, MIX-7807, MIX-7805, and MIX-3807, which were utilized for manufacturing drug substance batches 5007522046, 5007522017, 5007522119, 5007522125, 5007522131, 5007522135, 5007522136, 5009222022 and these batches were released.
- Observation 2
Cleaning validation not representative
OBSERVATION 2 Cleaning Validation studies of non-dedicated manufacturing equipment did not include challenges with actual conditions used in routine manufacturing processes. Your firm's Cleaning Validation studies performed for (b) (4) and (b) (4) used for mRNA-1273 manufacturing utilized a "Mock" soil process prior to Clean-in-place (CIP) process. However, the "mock" soil process did not simulate the current manufacturing process. The procedure used during cleaning validation studies do not ensure that a similar manufacturing process was followed. For example, A. During routine manufacturing process, the (b) (4), Equipment ID# MIX-1805, MIX-1807, MIX-7807, MIX-7805, MIX-3807, and MIX-3805 are utilized for approximately (b) (4) for mixing of (b) (4) batch size of mRNA and lipid nanoparticles. The Cleaning Validation studies (VAL-PRO-6414, approved on 14Dec2022) included a "mock" mixing process of approximately (b) (4) using (b) (4) of drug substance. B. During routine manufacturing process, the (b) (4), Equipment ID# MIX-9805 and MIX-8805 are utilized for approximately (b) (4) for mixing (b) (4) batch size of mRNA and lipid nanoparticles. The Cleaning Validation studies (VAL-PRO-6414, approved on 14Dec2022) included a "mock" mixing process of approximately (b) (4) using (b) (4) of drug substance. C. During routine manufacturing process, (b) (4), Equipment ID# CRM-1413, CRM-3413, CRM-7413 and CRM-8413, are utilized for approximately (b) (4) of approximately (b) (4) using (b) (4) product. However, the Cleaning Validation studies included a "mock" process of approximately (b) (4) using (b) (4) product.
Show observations 3 to 5
- Observation 3
Expired materials not segregated
OBSERVATION 3 Separate or defined areas to prevent mix-ups are deficient. Your firm failed to discard or move expired and hold/restricted materials to physical hold location per SOP-0056 "Inventory Management and Control" to prevent the material being used beyond expiration date or restricted date. Expired materials were found utilized beyond their expiration date and restricted materials were utilized in mRNA drug substance production. There are more than two thousand expired items stored in your GMP Warehouse and Cold Storage at time of inspection. These materials are currently stored at the same location with released or in-used materials. There was no clear demarcation between these items in the GMP Warehouse and cold storage. For example, expired material stored in GMP storage were observed during the walk through on 9/11/2023 and 9/12/2023 : i. (b) (4), Batch# (b) (4), expired 26Aug2023 ii. (b) (4), Batch# (b) (4), expired 27Jul2023 iii. (b) (4), Batch# (b) (4), expired 19Jul2023 iv. (b) (4), Batch# (b) (4), expired 17Mar2023 v. (b) (4), Batch# (b) (4), expired 28Feb2023 vi. (b) (4), Batch# (b) (4), expired 31Dec2022.
- Observation 4
Alarm response and effectiveness checks deficient
OBSERVATION 4 Written procedures were not followed. Specifically, A. SOP-0416, Alarm Response Program, required the alarm acknowledgement within (b) (4), impact assessment within (b) (4) of alarm notification and QA review within (b) (4) of impact assessment completion. Your firm failed to respond and follow upon the alarm responses within the timeframe established per SOP-0416. For example: 1. Differential Pressure (DP) alarm for Grade C room 1183 on 6/24/2023 - The alarm acknowledgement and impact assessment were conducted and entered on [illegible] system during FDA inspection on 9/13/2023. II. DP alarm for Grade C room 1183 on 1/30/2023 - The alarm impact assessment was completed on 2/23/2023, QA review was completed on 8/11/2023. III. DP alarm for Grade C room 1183 on 1/23/2023 - The alarm impact assessment was completed on 1/23/2023, QA review was completed on 2/8/2023. IV. Temperature alarm for (b) (4) Cold Storage 1677 on 4/18/2023 - The alarm impact assessment was completed on 4/19/2023, QA review was completed on 7/12/2023. V. Temperature alarm for (b) (4) freezer 1678 on 1/24/2023 - The alarm impact assessment was completed on 1/24/2023, QA review was completed on 3/16/2023. VI. Temperature alarm for (b) (4) 1678 on 7/26/2023 - The alarm started on 7/26/2023, alarm acknowledgement on 7/27/2023. There is no impact assessment or QA review as of this inspection. The freezer was never taken out of service and currently in used to stored GMP materials. B. Effectiveness check based on updated cleaning process was not evaluated as per the written program. Change Control QE-016513 (implementation date of 14Sep2022) was initiated to update the automated cleaning procedure of (b) (4), Equipment ID# MIX-1805, MIX-1807, MIX-7807, MIX-7805, MIX-3807, and MIX-3805. A cleaning procedure update was implemented based on the change control and a six-month effectiveness check through cleaning verification after each equipment usage (due date: 14Mar2023) was required after the implementation of change actions to review cleaning verification data to ensure automated method change was effective. However, the cleaning verification samples were not collected after 06Feb2023.
- Observation 5
Air handling / pressure control failures
OBSERVATION 5 Equipment and Facilities are not designed to minimize potential for contamination. Specifically, the air handling systems were not adequately designed and controlled to assure appropriate air quality in the Grade C cleanroom in which mRNA drug substance is manufactured. The positive pressure was not consistently maintained between the Grade C cleanrooms and Grade D Airlocks. Monitoring data from (b) (4) system showed frequent drops of Grade C Cleanroom pressure to negative values between January 2023 and September 2023. The negative DPs (differential pressure) were not assessed for potential impact. Furthermore, the Cleanroom Open Door recovery study conducted during FDA inspection on 9/15/2023 under VAL-TP-0034 for Grade C room 1311 shows that Grade C Cleanroom lost differential pressure to negative value immediately when the door was opened to the Grade D airlock.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on Sep 23, 2024. Each one asked for a Form 483.
Inspection ending Sep 21, 2023VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Nov 2, 2023FDA-FOIA-2023-9704Form 483Closed
Inspection date not given
3 requests. None of FDA’s log entries for these requests say records were released.
- Sep 23, 2024FDA-FOIA-2024-8387Form 483 + EIRClosed
- Jan 3, 2024FDA-FOIA-2024-61Form 483 + EIRWithdrawn
- Jan 2, 2024FDA-FOIA-2024-45Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Moderna US, Inc.D-U-N-S 117626450
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Moderna US, Inc. (D-U-N-S 117626450) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- MODERNA BIOTECH SPAIN SL.Madrid, Spain · FEI 30301553161 inspection1latestNov 21, 2025NAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3014937058 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3014937058. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.