FDA has one inspection on file for Pet Pharmacy NW LLC in Corvallis, Oregon (FEI 3014597434). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2019
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate aseptic technique

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, the sterile drug technician demonstrated inadequate aseptic technique during non-sterile to sterile drug production operations on 12/10/2018. For example; A. Mixing drug components in non-depyrogenated equipment. B. Disinfecting equipment (vial, (1:5) (b)(4) and rubber vial stopper) with non-sterile (b)(4) using a non-sterile wipe. C. Jewelry not removed prior to donning sterile gloves. D. Donning sterile gloves with gloved fingertips in contact with the non-sterile area of the inside cuff. E. No disinfection of the ISO5 classified LAFH prior to production. F. The operator was observed leaning into LAFH during production with facial protection that was not worn appropriately during production to provide an adequate seal. G. Crimping equipment was used outside the ISO5 classified zone with a vial cap and crimping tool that had not been disinfected prior to use and gloves that were not disinfected prior to vial being sealed. H. Media fills are conducted but do not include the most challenging process performed as described by the Pharmacist in charge and the sterile drug technician. I. Dynamic smoke studies have not been conducted to demonstrate airflow during production. Add Continuation Page

    2. Observation 2

      Deficient environmental monitoring

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. On 12/10/2018, sterile drug production was conducted after observing water dripping from the ceiling tile of the clean-room. The ceiling tile was subsequently removed but not re-installed and sealed prior to production. Recertification of room was not conducted for approximately [illegible] days. B. Pressure differentials between classified and unclassified areas are not monitored daily. Magnehelic gauges used were observed to be either non-functional or incorrectly installed. C. Environmental monitoring of ISO classified zones is conducted on [illegible] basis and (b)(4) via an unqualified (b)(4) sampling method at unknown locations. D. Personnel monitoring is conducted using samples taken from the gloved hands of employees following sterile drug production at least (b)(4) but not following each sterile drug product produced.

    Show observations 3 to 10
    1. Observation 3

      Inadequate cleaning/disinfection

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, A. The ISO5 classified zone is cleaned using non-sterile (b)(4). B. Non-sterile wipes are used to clean the ISO5 classified zone. C. The ISO5-7 classified zones are not cleaned with any sporicidal and no dwell time is established for disinfectants used. Add Continuation Page

    2. Observation 5

      No sterility testing of batches

      Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements. Specifically, There is no established testing program for any of your sterile drug products to demonstrate products are indeed sterile and pyrogen free prior to being distributed. For example, the following sterile drug products that were distributed as office stocks did not have sterility testing: 1. Rx (b)(6) for 5 mL Papaverine-Phentolamine-PGE1 22-0.8 mg-8 mcg/mL Injection solution; lot 01102018@9; produced 10/1/18. 2. Rx (b)(6) for 30 mL Cyclopentolate-Phenylephrine-Tropicamide Ophthalmic Solution; lot 27092018@11; produced 9/27/18. 3. Rx (b)(6) for 10 mL Hydroxyprogesterone Caproate 250 mg/mL Oil Injectable Solution; lot 19062018@11; produced 6/19/18. Add Continuation Page

    3. Observation 6

      No potency testing before release

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release. Specifically, your firm does not regularly conduct any potency testing of sterile or non-sterile drug products produced at your facility. For example, the following sterile drug products that were distributed as office stock did not have potency testing: 1. Rx (b)(6) for 5 mL Papaverine-Phentolamine-PGE1 22-0.8 mg-8 mcg/mL Injection solution; lot 01102018@9; produced 10/1/18. 2. Rx (b)(6) for 30 mL Cyclopentolate-Phenylephrine-Tropicamide Ophthalmic Solution; lot 27092018@11; produced 9/27/18. 3. (b)(6) for 10 mL Hydroxyprogesterone Caproate 250 mg/mL Oil Injectable Solution; lot 19062018@11; produced 6/19/18. Add Continuation Page

    4. Observation 7

      No stability testing / unsupported BUDs

      There is no written testing program designed to assess the stability characteristics of drug products. Specifically, the Beyond Use Dates (BUD) extended or otherwise used at your facility are not associated with any appropriate study intended to demonstrate the stability of finished drug products for characteristics such as potency or sterility. When asked to provide data used to establish extended BUD's, formulations by (b)(4) were provided. Per (b)(4): "in the absence of passing a sterility test under high-risk conditions (non-sterile to sterile production) storage periods cannot exceed the following time periods: - Controlled Room Temp (not more than (b)(4)) - Cold Temp (not more than (b)(4))" Add Continuation Page

    5. Observation 8

      Inappropriate personnel gowning

      Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform. Specifically, Re-usable non-sterile gowns, head covers, shoe covers and face covers are utilized in the production of sterile drug products. No eye-cover is used. Add Continuation Page

    6. Observation 9

      No microbiological testing of non-sterile products

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. Specifically, non-sterile drug products produced at your facility for office stock are not tested for the presence of objectionable microorganisms. A (b)(4) is used in the production of non-sterile drug products but the (b)(4) is not tested. Example of a non-sterile drug product for office stock: 1. Rx (b)(6) for 30 GM Lidocaine-Tetracaine-Phenylephrine HCl 20-4-2%; lot 22102018@10; produced 10/22/2018. Add Continuation Page

    7. Observation 10

      Use of non-pharmaceutical grade components

      You used a non-pharmaceutical grade component in the formulation of a drug product. Specifically, examples of non-pharmaceutical grade components used are: A. (b)(4) that was processed through a (b)(4) system that was not tested to ensure pharmaceutical quality prior to use for the formulation of non-sterile drug products. An example of a drug product formulated with (b)(4) produced for individually identified patients is Ketoprofen-Ketamine 5-5% Gel; lot 04092018@51. B. (b)(4). An example of a sterile drug product that was formulated using this non-pharmaceutical grade component and distributed as office stocks and individually identified patients is Prostaglandin 500 mcg/mL injectable under lots 23032018@36 and 03112017@21. Add Continuation Page

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3014597434 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3014597434. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.