Hallettsville Pharmacy, LLC
304 N Texana St, Hallettsville, Texas, United States
FEI 3014538927
FDA has one inspection on file for Hallettsville Pharmacy, LLC in Hallettsville, Texas (FEI 3014538927). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2018
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate cleaning to prevent cross-contamination
Your firm produced highly potent drugs without providing adequate cleaning of work surfaces and utensils to prevent cross-contamination. Specifically, A. (b) (4) drug products including Testosterone and Estriol are produced under a (b) (4) hood. Your procedures document that (b) (4) is used to clean the work surface in the hood between preparations. Your firm has no evidence to show that the use of (b) (4) will effectively remove residues which might be present on the hood surface after production. B. Your firm uses household dish liquid detergent and potable water for the cleaning of utensils such as rubber spatulas used in the processing of highly potent drug substances such as Estriol or Progesterone. All utensils are then washed in a dishwasher before subsequent use. I noted that several rubber spatulas used to transfer product were heavily stained. Your firm has no evidence to show that your cleaning procedures can adequately remove residual drug products or detergent.
- Observation 2
Non-pharmaceutical grade water used in formulations
Non-pharmaceutical grade components are used in the formulation of non-sterile drug products. For example, your firm uses (b) (4) water in specific formulations requiring water. The (b) (4) water is also used to produce (b) (4) Water which contains (b) (4). Your firm has no testing data to demonstrate that the (b) (4) Water meets, minimally, the specifications for Purified Water USP. Some examples of drug products which used (b) (4) Water include the following: A. Lidocaine 10/Prilocaine 10/Tetracaine 10/Phenylephrine 2%, lot #22983 was used with Rx #(b) (6) dated 9/21/18 B. Lidocaine 10/Prilocaine 10/Tetracaine 10/Phenylephrine 2%, lot #22867 was used with Rx #(b) (6) dated 8/27/18
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3014538927 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3014538927. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.