Laurus Labs Limited
25a Plot No 25, To 25k; Apsez Denotified Area, Lalam Koduru, India
FEI 3014255847DUNS 675474102
Company: LAURUS LABS LIMITED · Linked by exact D-U-N-S match (676413153) in FDA registration data
FDA has 2 inspections on file for Laurus Labs Limited in Lalam Koduru, India (FEI 3014255847), from 2019 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. Five FOIA requests have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant, LAURUS LABS LIMITED (D-U-N-S 676413153), has registered 4 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2019–2025
- 0 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 2
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 5 requests, latest May 5, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Unapproved equipment qualification protocols
Written procedures, including changes thereof, are not drafted, reviewed and approved by appropriate organization units, and approved by the quality control unit. Specifically, You failed to ensure that equipment qualification protocols are reviewed and approved by the quality unit. During the inspection, we observed multiple equipment used for the manufacturing of active pharmaceutical ingredients (i.e., [illegible]) qualified without an approved protocol. Examples of these manufacturing equipment include: Equipment ID Equipment Name Installation Qualification [illegible table/columns]
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Five requests to FDA under the Freedom of Information Act named this site, most recently on May 5, 2026. Each one asked for a Form 483.
Inspection ending Jan 31, 2025VAI
5 requests. In the inspection history above. FDA has posted its Form 483.
- May 5, 2026FDA-FOIA-2026-4430Form 483· 1 of 5 sitesWithdrawn
- Nov 3, 2025FDA-FOIA-2025-12544Form 483Records released
- Jul 23, 2025FDA-FOIA-2025-8947Form 483· 1 of 3 sitesClosed
- Jun 25, 2025FDA-FOIA-2025-8470Form 483Records released
- Jun 18, 2025FDA-FOIA-2025-7776Form 483· 1 of 10 sitesWithdrawn
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- LAURUS LABS LIMITEDD-U-N-S 676413153
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names LAURUS LABS LIMITED (D-U-N-S 676413153) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- LAURUS LABS LIMITEDMedchal-Malkajgiri, India · FEI 30065270153 inspections3latestSep 13, 2024NAINone on file
- LAURUS LABS LIMITEDAnikapalli District, India · FEI 30070836646 inspections6latestApr 19, 2024NAINone on file
- LAURUS LABS LIMITEDAnakapalli, India · FEI 30115385482 inspections2latestFeb 10, 2023VAINone on file
- LAURUS LABS LIMITEDAnakapalli, India · FEI 30170370901 inspection1latestOct 28, 2022VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3014255847 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3014255847. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.