Skip to content

North American Custom Laboratories LLC

1736 N Greenville Ave, Richardson, Texas, United States

FEI 3014229024

FDA has 2 inspections on file for North American Custom Laboratories LLC in Richardson, Texas (FEI 3014229024), from 2022 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published one citation from this inspection. It is listed below. One FOIA request has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Mar 10, 2022. FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations II). No court action or import refusal is filed under this FEI.

One regulation was cited at more than one inspection: FDCA 501(a)(2)(A).

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2022–2025
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
1 request, latest Oct 28, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 citation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Production areas, difficult to clean/particle generating

      Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Inadequate filter, final product sterilization

      The filter intended to render final product sterile was not pharmaceutical grade.

    2. FDCA 501(a)(2)(A)

      Disinfecting materials, aseptic processing area

      Materials or supplies were not disinfected prior to entering the aseptic processing areas.

    3. FDCA 501(a)(2)(A)

      Actionable microbial contamination, adjacent area

      You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in an area adjacent to the ISO 5 classified aseptic processing area during aseptic production.

    4. FDCA 501(a)(2)(A)

      Use of non-pharmaceutical grade components

      You used a non-pharmaceutical grade component in the formulation of a drug product.

    5. FDCA 501(a)(2)(A)

      Highly potent drugs, prevention of cross-contamination

      You produced highly potent drugs without providing adequate containment to prevent cross-contamination.

    Show 1 more citation
    1. FDCA 501(a)(2)(A)

      Non-sterilized and non-depyrogenated, sterile drug

      Non-sterilized equipment was used in sterile drug production.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Oct 28, 2025. It asked for a Form 483.

  • Inspection ending Sep 5, 2025VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Oct 28, 2025FDA-FOIA-2025-12409Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3014229024 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3014229024. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.