Alvotech Hf
Saemundargotu 15-19, Reykjavik, Iceland
FEI 3013702557DUNS 500791692
FDA has 3 inspections on file for Alvotech Hf in Reykjavik, Iceland (FEI 3013702557), from 2024 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. One of the 10 FOIA requests for this site has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is Alvotech Hf (D-U-N-S 500791692).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2024–2026
- 0 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 3 posted 483s not matched to an inspection
- Requested under FOIA
- 10 requests, latest FY2023
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Complaint handling and investigations deficient
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed. Specifically, the quality unit failed to identify appropriate root causes and to implement corrections to reduce and adequately address the number of complaints for ®® drug product, Lo For example, Since 2024, the site received approximately 845 complaints related to drug product batches distributed to the US. The complaint review indicated significant number (approximately 50%) of the complaints were related to toy ,, malfunction such as “© ®@ ®@ a5 follows: Complaint Category Before 01SEP2024 04JUL2025 04JUL2025 Total number of complaints Total 15 292 538 845 Following deficiencies were observed during complaint investigation review: A. Consumer complaint COMP-2193 was reported for gq, on 3/3/2026 for ®© we | batchy. The firm manufactures bulk drug i Qe and sends to a third-party packing company to loo. The contract packing company verified that assembly batches wo: were used to pack batch. The contract packing company reported during this complaint investigation, “One incident occurred during the assembly process of batch m, but these had no impact on the complaint in question”. However, the details of this “Incident” were not shared by the contract packing company and the site failed to collect additional information about this incident if it might have caused the defect. The firm received twenty (20) complaints from this batch gq. The complaints attributed to gq xo. The site shipped approximately units of batch to the US in 2024. B. Consumer complaint COMP-1579 was reported for on 7/7/2025 for wo batch - The contract packing company reported during this complaint investigation, “An incident has occurred during the packing process, which has no impact on the mentioned complaint”. However, the details of this “Incident” were not shared by the contract packing company and the site failed to collect additional information about this incident if it might have caused the defect. The firm received thirteen (13) 5 complaints pertaining to this batch. The site shipped approximately gy units of batch yo; to the US in 2024. C. The firm management stated the complaint sample receipt rate for the US complaints is approximately 5%. The site failed to take appropriate actions to ensure complaint samples are received once the patient reports that the complaint sample is available. For example, consumer complaint COMP-001633 was received on 8/1/2025 pertaining to | batch yo fog. Review of the Complaint Intake Form (CMPLT-0008481) indicated the complaint sample was available. However, the firm did not make follow up 2nd or 3rd attempts (as indicated in Complaint Intake Form) to ensure the complaint sample is received for a thorough investigation. Additionally, the Complaint Intake Form used in complaint investigation is not filled completely with all required information and it is not approved by the personnel concerned. The firm management agreed that their complaint investigation is based on incomplete Complaint Intake Form. D. Your risk assessments conducted as per deviations DEV-005067 and DEV-005068 for consumer complaints related to xed respectively are deficient. In both deviations, the site did not find any root cause for these defects ne PY The site categorized these defects as low risk to the patient, and no corrective actions were taken. However, in these investigations, the firm failed to thoroughly investigate why the Lo is failing to perform as intended. On 5/5/2026, the firm’s VP Quality confirmed that the site did not submit any BPDR for the malfunctioning
- Observation 2
Inadequate aseptic process validation
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, in the video for airflow visualization studies of the aseptic fy, filling line used to produce all drug products (VALQ - 8900 - L3-2b, performed on August 15th, 2023), the qualification of the i, me intervention to add unopened stopper bags showed that airflow from the filling unit into the stopper loading station causes a void over the unopened stopper bags, preventing first-pass airflow from reaching the bags while they The stopper bags are not further disinfected before they are opened 10 g
Show observations 3 to 5
- Observation 3
Visual inspection requalification lacking
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, requalification for employees performing 100% visual inspection for particulates on Lo is performed © after each employee has completed inspection of; QO despite the fact that the employees will inspect up to during op. There has been no initial or requalification after | inspection to demonstrate that the employees can perform the operation adequately
- Observation 4
Deviation investigations and risk assessment inadequate
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, deviation investigations pertaining to above-action excursions, including observed objectionable microorganisms in i, system were not thoroughly investigated to include the risk assessment extended to the batches manufactured that time. For example: A. A holistic deviation investigation, DEV-005216 was initiated to investigate multiple incidents (during ), when above action limit results were observed pertaining to fy testing for bioburden at sampling location area (room ID: in drug substance manufacturing facility i. This investigation was initiated in response to the samples collected from the jj 100m on jy gy when total viable count of CF Uy mL was observed for. Bioburden test against the Action Limit of 2@ CFU/g, mL. In room, the site recovered two objectionable microorganisms Ralstonia insidiosa and Ralstonia pickettii in addition to other organisms including Herbaspirillum aquaticum / huttiense, Methylobacterium aquaticum, Rhodotorula mucilaginosa, and Sphingomonas parapaucimobilis / yabuuchiae. During the investigation, the firm identified loop serving g as the most probable source of contamination. The firm’s impact assessment is deficient as the scope of the risk assessment was not extended to gf batch of a iN ROW markets) and |] batches oe of manufactured during that time. Other incidents when the site observed above action gq, bioburden results including objectionable organisms in gq, room (room ID: include the sampling that was performed ong (DEV-004932) and (DEV-005916). B. Deviation investigation DEV-005188 was initiated when above-action bioburden test results were observed for the ), samples collected on IY from © loop (sampling location: - For this location, the site observed total viable count of ®@ CFU/g, mL against the Action Limit of 2& CFU, mL. The organism identified in this excursion was gram negative Methylobacterium radiotolerans. The loop for gy ww Was identified as a probable root cause for this deviation as well. This deviation impacted om drug substance manufacturing areas gq. However, the firm’s impact assessment was deficient as the scope of the risk assessment was not extended to the batches manufactured in - areas. In addition to the batches ew discussed in bullet point 4A) manufactured in arca; the site manufactured i batches fi ®@ in 1) manufacturing area. Drug substance © ROW markets. Other deviation investigations that were not conducted thoroughly include DEV-005067 and DEV-005068 and are discussed in Observation 1D.
- Observation 5
Quality unit failed to follow procedures
The responsibilities and procedures applicable to the quality unit are not fully followed. Specifically, the quality unit failed to ensure environmental monitoring trend reports are generated as required under SOP-0509, Trending of environmental monitoring data. For example, Environmental monitoring and fy, Trend Review Reports pertaining to drug product and drug substance manufacturing areas were not generated, reviewed, and approved from ® @. The firm's Contamination Control Program (SOP-1858) requires Contamination Control Board (CCB) members to meet to discuss EM results and trends and to take appropriate actions. Review of the CCB meeting minutes for ®@ indicated that the CCB discussed various EM Trends; however, this deficiency i.e., creation, reviewing, and approval of trend reports was not part of the Contamination Control Board meeting agenda.
- Not classified yetClassification not posted yetPosted 483 · 10 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Lack of production/process procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, Per SOP-0832 Application (00 2024), [illegible] applied to [illegible] and included (b)(4) [illegible] justification to demonstrate [illegible] adversely impact product quality and stability.
- Observation 2
Quality unit responsibilities not followed
The responsibilities and procedures applicable to the quality unit are not fully followed. Specifically, A. Since January 2025 you received [illegible] associated with (b)(4). You identified [illegible] reduced complaints with similar complaints (b)(1) use error [illegible] providers' scientific justification for trending a [illegible] complaint. Although none of these complaint categories reached the upper control limit (UCL) variation when analyzed individually, the UCL was exceeded when the complaints were analyzed together. No evidence was provided that this upward trend was evaluated. CAPA was initiated 03 Jul 2025, and no supplier investigation was initiated prior to the closeout of the inspection on 04 Jul 2025. B. Not all drug substance (DS) lots are withheld from use until the lots have been fully reviewed and released by the quality control unit. Per SOP-1680 Product Ver 10.0 (Effective Date 19 Nov 2024), drug [illegible] unprocessed bulk virus testing results and without the completion of data reviews by your quality unit. C. There was a lack of quality oversight for the planning and initiation of [illegible] runs as documented in DEV-003670. These runs were planned prior to closure of a [illegible] associated with the previous failed PPQ documentation. D. A quality agreement between your firm and the applicant/contract manufacture was [illegible] in place at the start [illegible] quality unit of the sponsor for the quality [illegible].
Show observations 3 to 10
- Observation 3
Inadequate contamination controls and EM program
There is a lack of assurance that your drug substance and drug product manufacturing operations are appropriately designed to prevent contamination or product adverse effect on product quality. Specifically, A. The microbial controls of your DS manufacturing process are deficient. For example, i. You do not have adequate microbial control [illegible] bioburden excursions in [illegible]. Viral inactivation unit operations were [illegible]. Additionally, [illegible] after storage, for [illegible] products. ii. [Illegible] evidence of filamentous fungi recovery from the product stream [illegible]. iii. [Illegible] cleaning sample collected during [illegible] was used for [illegible]. Bioburden samples are sampled for bioburden out of storage following [illegible] that the obtained results are reflective [illegible]. iv. On [01 Jul 2025] observed collection of [illegible] of batch [illegible] was not performed [illegible] of the formulated bulk at the end. v. [Illegible] established microbial sample hold times for your bioburden and endotoxin samples is NMT [illegible]. You calculate sample hold time from the time [illegible] from the time of its collection. B. The environmental control of the classified process areas in [your] facilities is deficient. This is evidenced by: i. Classified areas of your facility exhibit consistently elevated microbial contamination recovery rates (CRR). For example, the following trends were observed in 2024: a. CRR over [illegible] were observed for various sample types in Grade B side Feb-Dec 2024 (up to [illegible]). b. Grade C areas in the facility exhibit consistently high [illegible], for example, Grade C side of the entry [illegible] in Feb-Dec 2024. c. Mold and filamentous fungi were repeatedly detected in classified areas January 2023 through December 2024 (DEV-003110 and DEV-003253) and room associated deviations were opened and closed without a CAPA being implemented. You [illegible] contamination control program improvement. At the time of inspection in 2025 several CAPAs are pending implementation. ii. Your alarms for differential pressure between areas [illegible] in drug product process areas are not appropriately established to ensure that at least a positive pressure differential is maintained between adjacent rooms. Lower limit differential pressure set points [illegible] from the Filling room (Grade B) [illegible]. iii. The maximum occupancy study performed as part of Environmental Monitor Qualification (EMQ) of [illegible] area is inadequate. For example, a. It did not challenge maximum occupancy of [illegible]. b. Maximum occupancy of production rooms was not always challenged through the duration of environmental sample collection. For example, [illegible] room [illegible] the recommended maximum occupancy [illegible]. iv. During gowning entry into Grade C rooms [illegible] leaving [illegible] shoes exposed in Grade D; gloves are replaced upon crossing to Grade D side of [illegible]. C. The routine environmental monitoring (EM) program at the facility [illegible] environmental contaminants and monitoring: i. A limited number of worst-case locations are included [illegible] sampling in all classified areas. ii. You did not establish contamination recovery rate limits for [illegible] facility and collect this data for information only. Additionally, recovery rates for different sampling methods are combined, potentially masking significant trends. D. Your firm lacks an established cleaning and sanitization program to prevent the introduction of microbial contamination into controlled sterile DP manufacturing environment. In particular, i. The disinfectant efficacy study does not support the intended use of the cleaning reagents as it was not performed at the end of the assigned post-opening [illegible]. Additionally, efficacy of all disinfectants used was not evaluated in conjunction with mechanical action (wipe). ii. Your SOP-1911 ver.16, effective [28 Jul 2024], specifies conta
Shortened here; the PDF has the full text.
- Observation 4
Aseptic processing and personnel deficiencies
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, A. While observing aseptic setup and filling operations of product Batch [illegible] (01 Jul 2025), the following deficiencies in the [illegible]: i. During the [illegible] the [illegible] air above the [illegible] allow units within the Restricted [illegible]. ii. During installation of the filling and [illegible] unprotected sterile parts, including [illegible] were handled with gloved hands. These components are positioned directly above [illegible] and product during the filling and stoppering process. iii. During [illegible] tube installation, the operator's gloved hand and non-sterile [illegible] disrupted the first airover the exposed tube. B. Your visual inspection program does not provide adequate assurance that finished products manufactured at your facility possess their purported quality attributes. Specifically, containers containing foreign matter or particles in [illegible] and their potential to compromise container integrity and the sterile product. C. Aseptic personnel qualification does not require demonstration during process simulation (media fill). Currently [illegible] interventions. No evaluation was conducted of routine and corrective critical intervention [illegible] filling and stoppering parts during aseptic process simulation. D. Your firm lacks adequate assurance that [illegible] manufactured are maintained in a validated [illegible] used for sterilizing drug product have proper validation or routine revalidation.
- Observation 5
Inadequate investigations and record follow-up
Written records of unexplained discrepancies or the failure of a batch or any of its components to meet specification, do not always contain a thorough investigation, or appropriate documentation, conclusions, and follow-up. Specifically, A. You implemented a QMS update for management of OOS/OOE events and associated manufacturing investigations under one laboratory investigation. As a result, in deviation from your SOP-0922 v.18 for unplanned departures from specification, acceptance criteria or other conformance standards confirmed by your initial laboratory investigation, some laboratory investigations were not included in your [illegible]. B. Your SOP-0922 v.18 provides for cancelation of investigations by justification by your Quality Unit (QU). For example: i. DEV-3197 opened 10 Aug 2022 for [illegible] during manufacture of [illegible] batch. The investigation was cancelled without further investigation of product and process impact and due to being a "one time" event for the same batch. ii. DEV-4246 opened 11 Oct 2024 for [illegible] personnel monitoring; DEV-4308 opened [illegible] recovered from personnel monitoring, DEV-4754 opened 22 [illegible]. In all cases another objectionable organism, Pseudomonas spp., was identified and these deviations were cancelled. iii. DEV-3189 opened 01 Aug 2023 for failure to remeasure process endotoxin sample within the required sample hold time was cancelled with a conclusion that the sample hold time was applicable only and the deviation was raised in [illegible]; there is masking in the samples held for over [illegible]. C. Your SOP-0922 v.18 provides for managing minor departures from GMP/GDP as quality incidents (Ql-xxxx or EVxxxx-xxx prior to 01 Dec 2024). Such incidents are not always fully investigated and remediated as root cause is deemed obvious. For example, i. From 10 July 2024 you opened 17 quality incidents and events involving failure to review various logbooks within the required timeframe. Although CAPAs were implemented in response to some of these events, they failed to prevent their reoccurrence. ii. Several quality incidents related to data [illegible] on 03 Dec 2024 for operator using "calibration" login, Ql-000088 opened [illegible] for issuing controlled document without required header and footer were closed by QA without further investigation. iii. Several quality incidents were closed with QA [illegible] opened 28 Jan 2025; [illegible] excursions 2025 (deviation from [illegible] requirements), and Ql-000107 opened [illegible] entry performed in MBT- [illegible]. There is no evidence that investigations were performed for any of these quality incidents. vi. Ql-000106 opened 21 Feb 2025 for use [illegible] cable due to the correct label [illegible] alarms from blocking the (b)(4) initiation. The incident was closed without investigation to be managed under a temporary change control. These events represent departures from GMP requirements and therefore do not meet your definition of quality incidents in SOP-0922 v.17 effective [illegible]. D. There is no assurance that the deviation recurrence check required as part of deviations and quality incidents per SOP-0922 is performed consistently: i. Deviation recurrence check performed for Ll-xxxx, DEV-xxxx, Ql-xxxx records is limited to their respective pool and does not include [illegible]. ii. The QMS recurrence check functionality used for DEV-3417 for pipette calibration failure opened [illegible] performing recurrence check for the pipette calibration failure opened on [illegible]; deviations are not being masked from recurrence check performed by the current QMS version. iii. You did not perform recurrence check for Ql-xxxx records opened [illegible] SOP-0922 v.18 requiring opening a deviation [illegible] period was approved. No retrospective review [illegible]. G. Critical deviations are not always classified [illegible]. For example 17 Apr 2024 for [illegible] DeltaV system alarms [illegible] major. H. Du
Shortened here; the PDF has the full text.
- Observation 6
Deficient laboratory controls and OOS handling
Laboratory controls do not include the establishment of appropriate standards designed to assure that components and in-process materials conform to appropriate standards of identity, strength, quality, and purity. Specifically, A. [Illegible] duplicates within [illegible] control data analysis for [illegible] percent coefficient of variation [illegible]. B. Current procedures for managing critical QC reagents are inadequate. Specifically, inventory [illegible] performed for primary and working reference standards for [illegible] which included directly placing them at room temperature, which may impact the stability of [illegible]. C. An out-of-specification (OOS) result was reported under Ll-001187 for potency testing of drug product. While the initial lab investigation did not identify obvious errors, the OOS investigation was closed without conducting a thorough root cause analysis prior to repeat testing. D. A corresponding OOS result (OOS - 0144) was observed for subvisible particles >1 [illegible] USP limits during fill homogeneity testing and was linked to the beginning of the fill. The batch was released based upon a central release [illegible] to the process. QC testing evaluates [illegible] filling process. This investigation was inadequate regarding testing for subvisible particles.
- Observation 7
Poor documentation and access control
Your firm's documentation practices are deficient. Specifically, A. During batch record review, I (LB) noted that [illegible] performed by operator and verified by second person as having been observed (Step [illegible]). A lack of good documentation practices is also evidenced by deviations related to incomplete documentation and missing second person verification, dating from Sep 2023 (major DEV-003274) to Jun 2025. You failed to implement an adequate and effective CAPA to address the recurring practices. B. The filter integrity testing records for High-Efficiency Particulate Air (HEPA) filters in classified manufacturing areas and those installed in the [illegible] do not include complete records of [illegible]; penetration value(s) for each test is (are) not documented in the event of an HEPA filter integrity test failure. You do not adequately ensure the accuracy and completeness of these records. C. Your firm failed to implement appropriate access control over controlled documents and systems: i. During a tour of QA area on 01 July 2025, controlled [illegible] were found in an unsecure location where they could be accessed. Additionally, keys to access GMP documents that are under revision and moved into the archive are kept in lockboxes with a numeric code access. Although some of these lockboxes are located within the general access area, the codes are not periodically changed and there is no system in place for lockbox access traceability. ii. During tour of the QA office responsible for issuing batch records on 01 July 2025, the office was observed open. The office is used for printing and storage of the colored batch record paper. iii. Controlled documents are accessible and can be printed by unauthorized personnel, as evidenced by DEV-003418 which occurred 01 July 2025, DEV-003513 which occurred 22 Nov 2023, DEV-003732 which occurred 01 Dec 2023, and EV2024-056 which occurred 27 Sep 2024. This was also demonstrated by logging onto the Veeva system during this inspection. Your firm failed to implement adequate CAPAs to ensure proper control over access. iv. Management of superseded versions of controlled procedures (SOPs) is inadequate. Superseded versions of the Master Batch Record (MBR) and manufacturing laboratory records (MLR) were printed for use, as evidenced by EV2024-077 (occurred on 27 NOV 2024), Ql-000331 (occurred 25 MAR 2025). In addition, superseded versions of SOPs can be [illegible]. D. Master Batch Record (MBR) Instructions are inadequate or unclear. For example, Step [illegible] the [illegible] and the [illegible] are not precise. The calculation of [illegible] is incorrect in the batch records. The calculation [illegible] based on the [illegible].
- Observation 8
Inadequate computerized system controls
Your firm failed to exercise appropriate controls over computerized process control systems used for OS and DP manufacturing and testing. Specifically, A. Unique login identifications for each user have not been established; for example, two staff use a shared username and [illegible] to access the data acquisition of critical process equipment, including [illegible]. B. The electronic data review process is deficient. For example, audit trails enabled in the data acquisition systems are not reviewed for each data set during the [illegible] review processes. In addition, during data review, [illegible] results are reviewed and they are not verified against the original electronic records. C. During the power outage in January 2024, the [illegible] when the DeltaV Professional PLUS server could not be restarted and required database restoration. A revalidation of the computerized system was not performed after the system was restored.
- Observation 9
Quality unit oversight inadequate
Your quality unit does not fully exercise its responsibilities for audits, oversight, and qualification. Specifically, A. Your quality unit has not conducted on-site GMP audits nor performed critical qualification and validation oversight. For example, no audits have been conducted of: i. [illegible] provider of qualification activities for the HVAC system (including Unidirectional Air Flow (LAF) units, and Microbiological Safety Cabinets). ii. [illegible] provider of validator test systems. B. You contracted to perform cleaning of Grade C and D areas. Although [illegible] cleaning was approved by QA in September 2020, the contract was not updated until 23 Jun 2025. The current agreement is low impact. Additionally, you did not ensure that training [illegible] GMP training.
- Observation 10
Deficient materials management and shipping controls
Materials management is deficient. Specifically, A. Management of raw materials is inadequate. Not all raw materials are tested prior to release for use. Based on the lists provided during the inspection, some raw materials are released solely based on [illegible]. B. There is a lack of documentation for disposal of contaminated [illegible] which was used in the production and subsequently determined to be contaminated based on DEV-00[illegible]. The contaminated [illegible] was discarded; however, no supporting documentation could verify the final disposal of this material. C. DS was shipped in a container closure not validated to OS bags following shipment to a CMO; the shipment did not include instruction for shipment [illegible], creating a potential safety risk for patients. Additionally, during the inspection, a total of [illegible] shipments utilized SOP-1483, v3.0, for movement of DS. Damage to the storage bags, if unnoticed, is a [illegible] risk.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality unit failed procedures
OBSERVATION 1 The responsibilities and procedures applicable to the quality control unit are not fully followed. A. Your Quality Unit failed to implement adequate and reliable controls for ensuring that distributed (b)(4) drug product, (b)(4) or any of its components always comply with the quality they represent to possess. Specifically, nine (9) complaints (No-USA distributed lots) related to (b)(4) mL (b)(4) product were investigated between March 2023 and August 2024, reporting issues with the (b)(4) (b)(4). Complaint Number Closing Date Description of the event (b)(4) COM-009 10-Mar-23 COM-024 03-Mar-23 COM-025 03-Mar-23 COM-026 01-Jun-23 COM-062 01-Nov-23 COM-086 10-Nov-23 COM-115 15-Jan-24 COM-154 26-May-24 COMP-001048 28-Aug-24 The complaint investigations identified (b)(4) as the root cause for the reported event. Per your Quality Unit, your Quality Unit continues to release batches of (b)(4), based on the risk assessment REP-4641 (Risk Assessment Report [illegible issue]) that concluded that "a (b)(4) will not cause a significant harm to patients." B. Your Quality Unit did not submit a Product Deviation Report (PDR) for the (b)(4) defect identified in the (b)(4) drug product (b)(4). According to your assessment, this defect could cause the (b)(4) of the drug (b)(4), meaning that since the (b)(4) does not perform as expected, the patient cannot administer the drug.
- Observation 2
Inadequate investigation of OOS endotoxin
OBSERVATION 2 Your firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications, whether or not the batch has already been distributed. From January 2022 to August 2024, your Quality Control (QC) laboratory invalidated approximately [illegible] endotoxin tests for [illegible], i.e., in-process (i.e., [illegible]) and drug substance/product samples. The out-of-specification results are associated to failures in spike recovery, sample Coefficient of Variation (CV) and spike CV. Your quality control laboratory has attributed the out-of-specifications (OOS) results to a combination of factors such as analysts' error, pipette contamination, and cartridges with "hot wells," among others. According to your assessment, "hot wells" is defined as one (1) sample channel of the cartridge reacting within the range of the curve (suggests endotoxin is present), and one (1) channel does not react (suggests no endotoxin presence). Additionally, "hot wells" shows variability in the CV producing OOS results. In those events where OOS results were invalidated due to pipetting error or sample contamination, your investigation does not include conclusive evidence to support the justification for invalidation. Additionally, it is unclear whether a corrective action was implemented. Regarding cartridges with "hot wells", your Quality Unit has not worked in continual collaboration with the cartridge supplier to ensure that quality commitments and reliability of the endotoxin test are met.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
10 requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.
Inspection ending May 8, 2026VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jul 9, 2026FDA-FOIA-2026-6571Form 483Records released
Inspection ending Jan 19, 2024
3 requests. Not listed in FDA’s Data Dashboard yet. FDA has posted its Form 483.
- Oct 18, 2024FDA-FOIA-2024-9239Form 483Closed
- Jan 26, 2024FDA-FOIA-2024-851Form 483Closed
- Jan 23, 2024FDA-FOIA-2024-736Form 483Closed
Inspection ending Jan 10, 2024
1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.
- Jan 24, 2024FDA-FOIA-2024-770Form 483Closed
Inspection ending Mar 22, 2022
1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.
- Sep 21, 2022FDA-FOIA-2022-6750Form 483Withdrawn
Inspection date not given
4 requests. FDA released records in answer to a request for its Form 483 + EIR on Nov 6, 2025. FDAgent holds no copy that FDA posted.
- FY2023FDA-FOIA-2023-3147Form 483Closed
- FY2023FDA-FOIA-2023-2454Form 483Closed
- FY2023FDA-FOIA-2023-2412Form 483Closed
- Nov 4, 2025FDA-FOIA-2025-12594Form 483 + EIRRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, API manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Alvotech HfD-U-N-S 500791692
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013702557 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013702557. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.