Generation Next Fertility
115 E 57th St Fl 11, New York, New York, United States
FEI 3013676494
FDA has 3 inspections on file for Generation Next Fertility in New York, New York (FEI 3013676494), from 2018 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 3 citations from this inspection, all under 21 CFR Part 1271, the rules for human cell and tissue products. They are listed below. Two of the four FOIA requests for this site have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 1271.47(a).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2018–2024
- 0 OAI · 2 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 3
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 4 requests, latest FY2023
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Risk factors, clinical evidence
Donors were not screened by a review of relevant medical records for risk factors and clinical evidence of communicable disease agents and diseases.
Accurate, indelible, legible
Donor eligibility records are not accurate.
Design of procedures to ensure compliance
Procedures were not designed to ensure compliance with the donor eligibility requirements.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Testing, screening, donor eligibility procedures
You did not establish and maintain procedures for testing and screening of HCT/P donors.
Determination based on screening and testing
HCT/P donors were not determined to be eligible based on the results of donor screening and testing.
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood Products2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Name and address on summary
The summary of records for HCT/Ps did not contain the address of the establishment that made the donor-eligibility determination.
Testing, screening, donor eligibility procedures
Procedures for all steps performed in the screening and determining of donor eligibility of HCT/Ps were not followed.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.
Inspection ending Jan 12, 2024VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jun 27, 2024FDA-FOIA-2024-5638Form 483Closed
- Feb 7, 2024FDA-FOIA-2024-1382Form 483Closed
Inspection ending May 25, 2022VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2022-7644Form 483Merged with another request
- Sep 13, 2022FDA-FOIA-2022-6573Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 4 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 1271.47What procedures must I establish and maintain?3 of 3
- 21 CFR 1271.55What records must accompany an HCT/P after the donor-eligibility determination is complete; and what records must I retain?2 of 3
- 21 CFR 1271.50How do I determine whether a donor is eligible?1 of 3
- 21 CFR 1271.75How do I screen a donor?1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013676494 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013676494. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.