AMMAN PHARMACEUTICAL INDUSTRIES
Building 108, Street A3, King Abdullah Ii Industrial City, Amman, Jordan
FEI 3013501887
FDA has one inspection on file for AMMAN PHARMACEUTICAL INDUSTRIES in Amman, Jordan (FEI 3013501887). It ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 11 observations from the PDF; they are listed below. Two FOIA requests have asked FDA for this inspection's 483.
19 import refusals are filed under this FEI, the latest on . FDA’s Red Lists for Import Alerts 66-40 and 66-41 name this firm at this address. FDA printed no FEI on the entries. No court action is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2023
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 2 requests, latest Feb 10, 2025
- Import refusals
- 19 refusals
- Import alerts
- 66-40, 66-41Red List
- Matched on FDA’s firm name and street address
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Aseptic handling and gowning failures
OBSERVATION # 1 Procedures designed to prevent microbiological contamination are not established and followed. During the set-up, filling, and transfer of equipment a processing behavior was observed in the aseptic filling lines identified as (b)(4). A. During set-up and aseptic filling on (b)(4) the following was observed: 1. The operators performing line set-up and manual interventions did not wear goggles, resulting in exposed skin in the Grade A areas. 2. During the filling from approximately (b)(4) there were approximately 376 times when an operator had to perform a manual intervention. During an intervention the operator had their head and torso inside the Grade A areas and leaned over open sterile product. 3. Prior to performing manual interventions inside of the Grade A area sterile primary packaging components are not cleared and subsequently handled. "Behavior Inside Sterile Area" instructs the use of forceps; however, none of the operators used forceps and they directly contacted sterile components or surfaces that were not subsequently disinfected. 4. The operators were observed repeatedly performing a manual intervention to inspect bottles for defects caused by the bottle sorting equipment. The operators would handle the open, sterile bottle with their hands. If there was no defect, the bottle would be placed back on the line. 5. During set-up, the sterilized tube used to transfer sterile filtered product into the (b)(4) was handled by the operator unprotected in the Grade B area multiple times. The operator touched the exterior surface of the tubing that was then placed inside the sterilized tube box. 6. During set-up an operator placed their forearm on the filling machine and pressed down on the exposed (b)(4). 7. The (b)(4) of the (b)(4), (b)(4) dropper stations, and open bottles were exposed for extended periods of time while the operator performed activities. 8. The panels below the filling machine were removed multiple times during the filling to make adjustments to the machine. The operators knelt while making adjustments and then touched surfaces inside the Grade A area without sanitizing their hands. 9. The operators were observed to remove bags of sterile components from (b)(4) and open them. The bags were carried through the Grade B area and placed on the floor in the Grade B area until they were needed. Bags of bottles were picked up off the floor, and bottles were poured into the (b)(4). 10. Employees were observed crawling under the machine on their hands and knees, sitting while leaning against the wall and the (b)(4) during these activities. 11. Operators were observed to pick rejected bottles, disinfectant bottles, and empty component bags up from the floor. They did not change gloves or disinfect their hands after this occurred. 12. An operator was observed to bring a cell phone into the aseptic filling room. B. During aseptic filling on the (b)(4) the following was observed: 1. An operator had exposed skin on their nose while they had their head and torso inside the Grade A area while loading sterile tubes into the tube box. While loading the sterile tubes, the operator reached over open sterile tubes and the tube box. 2. A second operator entered the aseptic filling room during ongoing operations without wearing any goggles, resulting in exposed skin on their face. The operator walked through a Grade A area. 3. Following a line stoppage due to a non-viable particle count excursion, the (b)(4) had build-up and could not be filled into tubes without build-up on the outside. The operator was observed to repeatedly wipe the excess product from product contact surface for the sterile product. The operator used a wipe that was previously used on non-product contact surfaces before use on product contact surfaces. The operator's gloved hands touched the product contact surface of (b)(4). 4. During multiple interventions to clear a jammed tube, the operator touched tubes that the operator touched or re
Shortened here; the PDF has the full text.
- Observation 2
Inadequate aseptic process validation
OBSERVATION #2 Procedures designed to prevent microbiological contamination include adequate validation of the aseptic process. A. Smoke studies have not been performed under dynamic conditions. The studies performed do not evaluate line set-up, do not evaluate the filling line during operation, and limited static studies that were performed do not allow for thorough evaluation and do not demonstrate air turbulence in the Grade A filling areas. B. Media fills are not designed to ensure they provide a representative challenge. The media fill protocols do not establish the number of interventions that must occur. Routine batch records did not include documentation of interventions. Documentation during the media fill did not specifically identify when interventions were performed. For example: 1. For the (b)(4) media fill the routine or media fill batch records did not document jammed tubes or cleaning of the tubes. These operations were not documented in the routine or media fill batch records, but were observed to occur multiple times on August 7, 2023, during aseptic filling of batch (b)(4). 2. For the sterile (b)(4) media fill jammed (b)(4) on the track near (b)(4) occurred. These manual interventions are not documented in routine records but were observed to occur multiple times on batch (b)(4). 3. For the sterile media fill (b)(4) a jammed (b)(4) station occurred. This intervention was not documented in the routine or media fill batch records, but was observed. C. Sealed, integral units are rejected during media fills and not incubated. The firm is not incubating these units. For example: 1. 200 rejected sealed bottles were not incubated during media fill (b)(4). 2. 67 rejected sealed tubes were not incubated during media fill (b)(4). 3. 17 rejected sealed bottles were not incubated during media fill (b)(4). D. Some components are not sterilized. On the Steril (b)(4) filling line, (b)(4) packaging components that contact sterile (b)(4) were disinfected, but not sterilized. E. On the Steril (b)(4) filling line, the tube box that contacts the tube, the tube contacting the open end of the tube, and the tube sensor that contacts the open end are disinfected between batches, but not sterilized.
Show observations 3 to 11
- Observation 3
Incomplete and inaccurate lab records
OBSERVATION #3 Laboratory records do not include complete data derived from a testing program and do not demonstrate compliance with established specifications and standards. A. Laboratory records document results for samples that were not collected. 1. Review of contemporaneous recordings of (b)(4) showed there were no settle plates or active air monitoring samples collected. The laboratory reported no growth because microbial media was not available. However, the batch record documents that all samples were collected and the microbiology laboratory reported no growth for these samples. 2. The (b)(4) operators performing filling activities and interventions during batch operations were documented in the batch record to have had personnel monitoring performed upon exit. Review of contemporaneous recordings showed no samples were collected. Operators confirmed no personnel monitoring was conducted because no microbial media was available. The laboratory reported no growth for these samples. 3. During batch (b)(4) video recordings show that active air samples were collected from different locations. The operator confirmed the samples were collected from the correct location because the operator was too busy to collect from the location specified. The active air samples and settle plates collected during filling were logged by the microbiology laboratory and placed in the incubator. Video recordings show the samples did not leave the filling room until approximately (b)(4) minutes later. 4. During decontamination of sterile (b)(4) biological indicators were documented to have been placed in (b)(4). Video recordings showed no biological indicators were placed during decontamination and there were no results for all (b)(4) samples indicating they were negative for growth. 5. The microbiology laboratory reported results for (b)(4) samples collected during aseptic filling. The batch record and sampling records show (b)(4) samples were not collected. B. Counting of colonies on microbial plates is not accurate. 1. Active air sample (b)(4) from the Grade A area associated with batch (b)(4) was read incorrectly. After the plate was read, the plate was observed to have more colonies than recorded. 2. Active air sample (b)(4) from the Grade A area with batch (b)(4) after the plate was read, the plate was observed to have additional colonies. C. Records are not made when plates are counted. Some plates were reportedly read on August 12, 2023, or August 13, 2023, for samples. For example: 1. Complete records were not made for environmental monitoring of aseptically filled batch (b)(4). During excursions, no counts were reported for any other Grade A, B, or C samples. Plates still available in the waste area identified additional Grade A samples containing microbial growth, Grade B samples with microbial growth, and Grade C samples with microbial growth. Specific examples with no recorded results were: a. Settle plate sample (b)(4) from the Grade B area (action limit (b)(4)) viewed on August 10, 2023, before the end of incubation, had visible growth but no recorded result. b. Settle plate sample (b)(4) from the Grade B area (action limit (b)(4)) viewed on August 10, 2023, before the end of incubation, had visible growth but no recorded result. 2. Complete records were not made for environmental monitoring of aseptically filled batch (b)(4). During excursions, no counts were reported for any other Grade A, B, or C samples. Plates still available in the waste area identified additional Grade A samples containing microbial growth and Grade C samples with microbial growth. For example: a. Settle plate sample (b)(4) from the Grade A area (limit (b)(4)) was viewed on August 10, 2023, before the end of incubation and had recorded (b)(4) CFU; in the waste area on August 13, 2023, there were (b)(4) CFU. b. Settle plate sample (b)(4) from the Grade A area (limit (b)(4)) was viewed on August 10, 2023, before the end of incubation and had recorded (b)(4)
Shortened here; the PDF has the full text.
- Observation 4
Deficient environmental monitoring program
OBSERVATION #4 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. A. Risk assessment 026-RMR/2021 justifies the environmental monitoring program based on risks that existed at the time of the assessment in October of 2021. It does not justify areas that must be monitored. For example: 1. There is no surface monitoring of locations in the Grade A area on a routine basis. 2. The (b)(4) area has no air monitoring (settle plates or active air) inside the barrier where bottles are filled, where the tube is inserted, and where the bottle is capped. The non-viable particle counter working height is approximately (b)(4) above from where bottles are filled. B. Personnel monitoring is only conducted (b)(4) and not during all activities associated with aseptic operations including aseptic connections and complex manual interventions. C. On August 9, 2023, operators in the Grade A area and in the (b)(4) preparation room were observed spraying disinfectant in a manner that exposed settle plates. Additionally, microbial media used for personnel monitoring was exposed to inactivating agents. D. Completed environmental monitoring and personnel monitoring records (b)(4) were not evaluated to determine whether there was recovery of microbial contamination. On August 7, 2023, personnel monitoring (b)(4) samples for batch (b)(4) were observed to be left in (b)(4) prior to processing. E. (b)(4) plates used for environmental monitoring are old, drying out, and cracked. F. Microorganisms isolated during environmental monitoring have not been fully identified to the flora of the aseptic manufacturing facility. Only (b)(4) organisms were chosen since procedure SOPQC068 "Microbe Identification Procedure", implemented in 2022, were from samples in the production facility. Identification only included colony morphology and Gram staining.
- Observation 5
Inadequate cleaning and disinfectant validation
OBSERVATION #5 Aseptic processing areas are deficient regarding the system to assure ongoing aseptic conditions. A. Following the filling of batch (b)(4) on (b)(4) cleaning log documents machine cleaning occurred; however, review of the log showed no machine cleaning was performed. Bottles were present from the prior batch and were still present at the start of the next batch. There was no machine cleaning observed in the contemporaneous video recordings before the next batch (b)(4). B. Disinfectant efficacy studies have not evaluated the effectiveness of disinfectants used on machine surfaces inside the Grade A area (b)(4). Additional evaluation is needed for (b)(4) covers over the (b)(4). Additional studies are needed for gloves worn by operators or the bags containing the (b)(4).
- Observation 6
Incomplete batch records for interventions
OBSERVATION #6 Batch production and control records do not include complete information relating to the production and control of each batch. A. Manual interventions requiring personnel to enter into the Grade A area are not recorded in the batch record. Prior to August 1, 2023, there was no requirement to record interventions on batch records that have been distributed to the US market. Form MMSQA002/F-01.00 was implemented on August 1, 2023, to record interventions. However, this form does not capture all manual interventions. For example on August 7, 2023, during the filling of batch (b)(4) the operator entered the Grade A area from approximately (b)(4) times to perform various manual interventions, but none were recorded on Form MMSQA002/F-01.00. B. Personnel working in the aseptic filling room are not permitted to have access to the batch records during the filling operations. Information related to the production including filling machine settings, interventions, and other information cannot be recorded contemporaneously by the responsible personnel. 1. Review of contemporaneous video recordings of the batch records for steps including filling, cleaning, and environmental monitoring did not reflect the actual activities during the batch record. For example, on August 7, 2023, during filling of batch (b)(4) the batch record showed intervention times recorded, however the contemporaneous video showed the operator entered the Grade A area 15 times to perform interventions that were not recorded contemporaneously. The review found that personnel in the Grade C area made entries on behalf of the operator in the filling room.
- Observation 7
Chromatography data handling deficiencies
OBSERVATION #7 Established test procedures are not followed. Procedures related to integration of chromatographic peaks and data review are inadequate. For example: A. During the review of the assay results related to the 18-month stability time point (b)(4) the integration parameters applied to the sequence were timed integration events, which forced the integration of all chromatographic peaks from (b)(4). These timed integration events were not proper integration according to SOP QC242 "Review of Chromatograms, and Documentation". In addition, integration parameters are not provided as part of the method, and the integration performed during the method validation was not reviewed. On August 15, 2023, the chromatographic data for the 18-month stability time point for (b)(4) were integrated using incorrect integration events which resulted in an OOS for (b)(4). B. The peer review performed by the supervisor does not require review of the electronic audit trail in the system unless manual integration is applied, and only those chromatograms printed within the ChromNav system are reviewed. According to SOPQC234, "Data Integrity and Electronic Audit Trail", the audit trail is required to be printed and reviewed; however your audit trails are reviewed electronically within the ChromNav system and not printed for review. C. The chromatography data previously processed within the ChromNav system can be overwritten when changes are saved by the analyst within the system. The original processed result is not preserved and available for data review. During the review of the 18-month stability time point for (b)(4) the chromatogram for (b)(4) that showed manual integration could not be retrieved within the chromatography system and was not available as part of the test package.
- Observation 8
Inadequate investigation of discrepancies
OBSERVATION #8 There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been distributed. A. Investigations into unexplained discrepancies during the manufacture are inadequate. For example: 1. Non-viable particulate (NVP) count alarms obtained during operations require the initiation of SOP VA067/F-01. During the manufacture of (b)(4) NVP out of limit excursions occurred, which required the operations to stop, samples to be collected, and recleaning when applicable. The investigation into the NVP out of limit excursions did not adequately assess the impact of the batch being filled as the (b)(4) that contains the sterile drug product was being processed within the environment where the excursion occurred due to openings in the equipment or personnel activities. There was no documentation that the recleaning conducted during the NVP excursion was performed as stated on the out of limit form. These out of limit forms are also not controlled. 2. During the manufacture of (b)(4) an unplanned deviation was initiated due to an outage of the particle counter as outlined in SOP PE010, "Operating of Air Particle Counter and Air Sampler". During the filling operation, NVP out of limits were obtained within the Class A area. A note was added to the record indicating the particle counter had a fault; however there was no investigation or NVP out of limit form initiated for the excursion. Furthermore, there is no procedure that provides instructions on the required documentation when the particle counter is out of service. B. Investigations initiated for drug products do not extend to other potentially affected batches. For example an investigation was initiated on October 6, (b)(4) for Lot (b)(4) containing foreign particles during in-process testing. The root cause was attributable to not verifying the (b)(4) of the (b)(4) during (b)(4). The investigation did not confirm if this root cause impacted any other batches manufactured. Procedure SOPQA076, "Deviation Handling Procedure", does not require that an assessment be performed on batches previously manufactured.
- Observation 9
Unsound HPLC assay validation
OBSERVATION #9 Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. The HPLC method for the Assay of (b)(4) is not scientifically sound to ensure that the method is robust or stability indicating. According to the validation report and your R&D personnel, no forced degradation studies have been performed to demonstrate the method utilized can adequately determine the assay concentration during stability, per SOP RD017, "HPLC Method Validation for Degradation Products". In addition, robustness testing was not performed during this method validation, which is required for non-official methods per SOP RD017, "HPLC Method Validation".
- Observation 10
Equipment design impedes cleaning
OBSERVATION #10 Equipment used in the manufacture, processing, packing or holding of a drug product is not of appropriate design and is not suitably located to facilitate operations for its intended use, cleaning and maintenance. A. The (b)(4) installed on sterile (b)(4) has areas that impede proper cleaning and airflow. B. The (b)(4) and (b)(4) on sterile (b)(4) line (b)(4) have exposed threaded bolts and nuts that contact sterile (b)(4) packaging materials. They are not designed to facilitate cleaning.
- Observation 11
Quality unit and supplier qualification failures
OBSERVATION #11 The responsibilities and procedures applicable to the quality unit are not fully followed. A. The qualification of suppliers is inadequate and does not follow SOP QA074, "Supplier Approval and Evaluation". For example: 1. The qualification documents provided for active pharmaceutical ingredient (API) suppliers for (b)(4) used for (b)(4) have not been reviewed and completed. According to these qualification documents, the suppliers provide a certificate of analysis; however these suppliers did not complete Section 12 indicating additional supplier information. The supplier questionnaire and qualification documents do not ensure that the materials supplied are manufactured in accordance with applicable Good Manufacturing Practices. Certificates for pharmaceutical applications are not provided. The qualification documents for (b)(4) have not been completed as per SOP QA074. The questionnaire used for (b)(4) suppliers does not ensure suppliers are appropriate for products intended for the US market. For example, the questionnaire does not request or confirm that the firm is registered with FDA, including for those suppliers providing an API. B. The Quality Control examination of incoming raw materials and packaging is inadequate. Sampling of Packaging Materials and Non-Sterile Raw Materials is not adequate. Per SOP QC060, the QC analyst examines the containers fully for appropriate labeling content and container damage. During the walkthrough of the warehouse on August 3, 2023, containers were observed with additional labeling which read "Samples not for human use". Procedure SOP QC060 does not describe the disposition of such labels and there was no conclusion regarding acceptance for drug product manufacturing. In addition, the (b)(4) for the physical status of this material had not been recorded.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Feb 10, 2025. Each one asked for a Form 483.
Inspection ending Aug 15, 2023OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Feb 10, 2025FDA-FOIA-2025-1262Form 483Closed
- Oct 2, 2024FDA-FOIA-2024-8662Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3013501887, one row per refused product line.
19 refusals from 2022-11-23 to 2026-07-16 · charged DRUG GMPS on 19, FRNMFGREG on 5 · no FDA sample analysis
FDA firm profile- 2026-07-16
XYLOMETAZOLINE HCL (ADRENERGIC)60CBY53
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border ImportsSCS-9147237-0/10002/1
- 2023-08-29
WATER, PURIFIED (EYEWASH)65FBL06
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast Imports799-5894887-9/11/1
- 2023-08-18
SODIUM CHLORIDE (PHARMACEUTIC NECESSITY - TONICITY AGENT)55RY55
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast Imports799-5767052-4/11/1D
- 2023-08-18
SODIUM CHLORIDE (PHARMACEUTIC NECESSITY - TONICITY AGENT)55RY55
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast Imports799-5767052-4/11/1C
- 2023-08-18
SODIUM CHLORIDE (PHARMACEUTIC NECESSITY - TONICITY AGENT)55RY55
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast Imports799-5767052-4/11/1B
Show 14 more
- 2023-08-18
SODIUM CHLORIDE (PHARMACEUTIC NECESSITY - TONICITY AGENT)55RY55
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast Imports799-5767052-4/11/1A
- 2023-08-10
EMOLLIENT, LUBRICANT, N.E.C.64DBK99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of Northeast Imports799-5501972-4/21/1
- 2023-08-10
EMOLLIENT, LUBRICANT, N.E.C.64DBK99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of Northeast Imports799-5501972-4/11/1
- 2023-08-02
EMOLLIENT, LUBRICANT, N.E.C.64DBK99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of Northeast Imports799-5317651-8/31/1
- 2023-08-02
EMOLLIENT, LUBRICANT, N.E.C.64DBK99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of Northeast Imports799-5317651-8/21/1
- 2023-08-02
EMOLLIENT, LUBRICANT, N.E.C.64DBK99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of Northeast Imports799-5317651-8/11/1
- 2023-07-12
EMOLLIENT, LUBRICANT, N.E.C.64DBK99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports799-5525306-7/11/1
- 2023-06-09
EMOLLIENT, LUBRICANT, N.E.C.64DBK99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports799-5200251-7/11/1
- 2023-06-07
EMOLLIENT, LUBRICANT, N.E.C.64DBK99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports799-4631639-5/11/1
- 2023-06-07
EMOLLIENT, LUBRICANT, N.E.C.64DBK99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports799-4567573-4/11/1
- 2023-02-27
EXHIBITS - OTHER DRUG RELATED ITEMS N.E.C.66YBK99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of West Coast Imports286-6967893-1/21/1
- 2023-02-27
EXHIBITS - OTHER DRUG RELATED ITEMS N.E.C.66YBK99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of West Coast Imports286-6967893-1/11/1
- 2022-11-23
SODIUM CHLORIDE (REPLENISHER)65RAO19
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of West Coast Imports286-6962451-3/111/1
- 2022-11-23
SODIUM CHLORIDE (REPLENISHER)65RAK19
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of West Coast Imports286-6962451-3/101/1
Import alerts
FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.
- 66-41Red ListDetention Without Physical Examination of Unapproved New Drugs Promoted In The U.S.Import alert pageAlert on fda.gov
Date published 2023-09-12
- FDA’s entry
- AMMAN PHARMACEUTICAL INDUSTRIES · Building 108, Street A3, King Abdullah Ii Industrial City, Amman, The Capital JORDAN
- FDA’s inspection record for FEI 3013501887
- AMMAN PHARMACEUTICAL INDUSTRIES · Building 108, Street A3, King Abdullah Ii Industrial City, Amman, Jordan
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
239 products
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
Show 236 more products
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 Q Y - 58Glycerin (Pharmaceutic Necessity - Solvent), Not Elsewhere Classified (NEC)
- 55 R Y - 55Sodium Chloride (Pharmaceutic Necessity - Tonicity Agent), Not Elsewhere Classified (NEC)
- 55 R Y - 55Sodium Chloride (Pharmaceutic Necessity - Tonicity Agent), Not Elsewhere Classified (NEC)
- 55 R Y - 55Sodium Chloride (Pharmaceutic Necessity - Tonicity Agent), Not Elsewhere Classified (NEC)
- 55 R Y - 55Sodium Chloride (Pharmaceutic Necessity - Tonicity Agent), Not Elsewhere Classified (NEC)
- 55 R Y - 55Sodium Chloride (Pharmaceutic Necessity - Tonicity Agent), Not Elsewhere Classified (NEC)
219 more products on the alert page.
- 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov
Date published 2023-04-28
- FDA’s entry
- AMMAN PHARMACEUTICAL INDUSTRIES · Building 108, Street A3, King Abdullah Ii Industrial City, Amman, The Capital JORDAN
- FDA’s inspection record for FEI 3013501887
- AMMAN PHARMACEUTICAL INDUSTRIES · Building 108, Street A3, King Abdullah Ii Industrial City, Amman, Jordan
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
10 products
- 55 - - - --Pharm Necess & Ctnr For Drug/Bio
- 56 - - - --Antibiotics (Human/Animal)
- 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
Show 7 more products
- 60 - - - --Human and Animal Drugs
- 61 - - - --Human and Animal Drugs
- 62 - - - --Human and Animal Drugs
- 63 - - - --Human and Animal Drugs
- 64 - - - --Human and Animal Drugs
- 65 - - - --Human and Animal Drugs
- 66 - - - --Human and Animal Drugs
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013501887 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013501887. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.