Custom RX LLC
3510 N Ridge Rd Ste 900, Wichita, Kansas, United States
FEI 3013444075
FDA has 2 inspections on file for Custom RX LLC in Wichita, Kansas (FEI 3013444075), from 2017 to 2021. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on Aug 15, 2017. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 2, 2017–2021
- 1 OAI · 0 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 2
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance2 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Aseptic production contamination risk
You failed to prevent contamination while working in the aseptic production area (ISO 5 hood). Specifically, A) On 08/02/2017, I observed an aseptic operator produce sterile Magnesium Chloride Hexahydrate (PF), 5 mL vial 200 mg/ml injectable. During production, I notice the operator spray his gloves with sterile(1:5) (4) over open vials. The open vials contained finished sterile drug product. B) Your media tills are not representative of your aseptic production operations. The media fills conducted aseptically (b) (4} Specifically, your firm produces sterile drug products using bulk drug substances with volume sizes of up to(b)(4)ml. For example: •On 06/29/2017, you produced (ll) (4 )mlofAscorbicAcid(PF, Com Free) 500mg/ml injectable. The product was filled in SOml vials with lot number 06292017@6. You produced a total of! (1:5)(4) l
- Observation 2
Inadequate cleaning/disinfection of hood
You failed to adequately clean or disinfect the ISO 5 hood and equipment used in production. Specifically, A) Smoke studies utilizing(b) (4 base smoke were conducted in the ISO 5 hood on 12/20/2016 and 06/26/2017. Upon completion of smoke studies, there is no documentation indicating the production area was cleaned to remove smoke residue. The following sterile drug products were produced after the completion of the smoke study re-certification in the ISO 5 hood: • On 12/20/2016 - Acetylcysteine ophthalmic 10% solution lot 12202016@41 and Acetylcysteine ophthalmic 20% solution lot 12/20/2016@42. • On 06/26/2017 - Trimix 3011/0.02 mg/ml injectable lot 06262017@25. B) On 7/30/2017, during the sterile facility tour, I noticed a bottle of '(15) (4) ', a commercialized liquid detergent used for dishwashing. The liquid dishwashing soap was witnessed on the sink in the Ante Room (ISO 8 room). Your firm's management informed me the soap was used to wash glassware to be used in the sterile hood.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013444075 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013444075. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.