Skip to content

Park Infusioncare LP dba Preferred Homecare

13621 Inwood Rd Ste 420, Dallas, Texas, United States

FEI 3013330273

FDA has one inspection on file for Park Infusioncare LP dba Preferred Homecare in Dallas, Texas (FEI 3013330273). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER). FDA has also posted a Form 483 dated Aug 3, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2017
Inspections with 483 observations shown
1 of 1
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Vermin and cleanroom/hood deficiencies

      Vermin was observed in your production area. Specifically, 1. On 06/28/17, one dead insect was observed on top of ISO5 Hood [illegible] (Serial [illegible]) inside the Cleanroom. Additionally, one dead insect was observed on the bottom shelf of the refrigerator used for storing your finished produced sterile products and one dead insect was observed on the bottom shelf of the refrigerator used for storing drug ingredients to be produced. 2. Your ISO5 Hoods are not constructed for appropriate cleaning and maintenance. Reddish-brown residue was observed under the contact surface grating of ISO 5 Hood [illegible] and ISO 5 [illegible] (serial # [illegible]) where the operator performs sterile production. 3. Ceiling tile of the Anteroom appeared to display reddish-brown discoloration. 4. The Anteroom door was observed to have an approximately one and a half (1 1/2) inch gap from the bottom of the door to the floor which exposed the Anteroom to the unclassified area. According to your Pressure Gauge Readings Log from October 20-31, 2016, the pressure readings were documented as [illegible] for the Anteroom (your firm's specifications for pressure differentials in the Anteroom are to be greater than [illegible] the Cleanroom and the unclassified area). On 06/27/17, materials were observed being transferred from the unclassified area to the Cleanroom with the use of [illegible] while producing sterile drug products in the Cleanroom.

    2. Observation 2

      Glove use and aseptic technique lapses

      Personnel were observed touching equipment or other surfaces located outside of the ISO5 area with gloved hands and then proceeding with aseptic processing without changing or sanitizing gloves. Specifically, A. On 06/27/17, an operator was observed opening the door of the Cleanroom to grab supplies in the Anteroom and then re-entered the Cleanroom to proceed with the preparation of 3 in 1 TPN 120gm Protein 1800ml, for RX (b)(6), (b)(7)(c) without changing or sanitizing gloves. B. On 06/28/17, an operator was observed donning sterile gloves improperly by touching the outside of the sterile gloves with her bare hands.

    Show observations 3 to 5
    1. Observation 3

      Inadequate media fill simulation

      Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, your media fill consists of [illegible] and the contents get [illegible]. However, this process does not simulate the most challenging aseptic manipulations performed at your firm such as the processing of your TPN sterile products. According to your Pharmacy Manager, the aseptic process for TPN products requires the following steps which include but are not limited to: setting up the [illegible], the specified amount of ingredients (i.e., [(b) (4)] into the [illegible]) the operator [illegible] then the operator [illegible].

    2. Observation 4

      Non-sterile disinfectants/wipes used

      Disinfecting agents and cleaning pads or wipes used in the ISO 5 area (aseptic processing areas) are not sterile. Specifically, A. Disinfectants, [illegible], and [illegible] wipes, used to clean surfaces and equipment in the ISO 5 Hoods, ISO 7 Cleanroom, and ISO 7 Chemoroom are non-sterile. B. The low-lint wipes used to clean surfaces and equipment in the ISO 5 Hoods are non-sterile.

    3. Observation 5

      Inadequate environmental monitoring/incubation

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Your environmental monitoring samples (viable air, surface monitoring plate, and finger touch plate) are not incubated at an adequate temperature and duration to recover the appropriate microorganisms. Per manufacturer's instruction for use of contact sampling plates, "[illegible]". However, your environmental air and [illegible] surface contact plates sampled from ISO 5 Hoods were documented to be incubated only at [illegible] (C) for [illegible] days. Additionally, finger touch plates were also documented to be incubated only at [illegible] (C) for [illegible] days. B. According to your ISO rooms and hoods certification records, [(b) (4)] was recovered from viable air sample collected from your ISO 5 [(b) (4)] (Serial # [illegible]) on 04/24/17 and on 10/17/16. Your firm has not performed investigation into the source of the contamination.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3013330273 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3013330273. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.