Genetech Inc
3030 Bunker Hill St Ste 308, San Diego, California, United States
FEI 3013306140
FDA has one inspection on file for Genetech Inc in San Diego, California (FEI 3013306140). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CBER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2018
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- · CBER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Blood and Blood ProductsPosted 483 · 9 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Donor eligibility not documented
ITEM 1 The eligibility of an HCT/P donor was not determined and documented by of donor screening and donor testing. A. Since operations began in mid-2017, there has been no documentation on whether donors of umbilical cord blood stem cells are eligible or not and there are no donor eligibility determination statements made Genetech, Inc. B. Relevant medical records, including the medical/social history interview and physical exams, are not consistently received from the umbilical cord blood recovery hospitals (suppliers). When these records are received from the supplier, they are not reviewed. The only records reviewed by Genetech, Inc. to determine whether to process the cord blood are communicable disease test results. [illegible] only provides a certificate of analysis. This supplier does [illegible] medical records which are needed to evaluate the donor for risk factors for and clinical evidence of communicable disease agents and diseases. C. For all products distributed since mid-2017, there is no completed summary of records [illegible] records provided by Genetech, Inc. The only information provided [illegible] disease test results and sterility test results.
- Observation 2
Unlicensed/unknown disease tests used
ITEM 2 Communicable disease agent tests were not FDA-licensed, approved A. All umbilical cord blood collections received by one [illegible] certificate of analysis. This certificate states FDA licensed or approved test [illegible] diseases, testing was performed in a "CUALab", and results were negative, but this testing, the test kit manufacturers, and actual test kits used are not known. B. Umbilical cord blood collected from donor [illegible] did not have appropriate test kits used. The test results received specifically state on HCV, and HIV [illegible] or [illegible] (if assay should not be used) results show a total CMV test was not performed separately. There are no HfLVI/II and WNV [illegible] perform and/or did not provide relevant medical records.
Show observations 3 to 10
- Observation 3
No donor eligibility procedures
ITEM 3 Procedures for all steps performed in the determining [illegible] implemented, followed and reviewed. Specifically, there are no donor eligibility determination procedures.
- Observation 4
No quality control unit
ITEM 4 There is no quality control unit. A. Umbilical cord blood stem cell Lot #: [illegible] Speciation was not performed. No investigation [illegible] to, reviewing environmental monitoring, equipment review, B. There are no written procedures that establish a quality [illegible] C. There is no documented final review/approval of [illegible] D. Procedure GEN-SOP-004, (Purification of Hematopo[ietic] Cord Blood), does not provide any incoming acceptance criteria E. The following procedures in use were prepared but not [illegible] 1) GEN-SOP-001, Laboratory Safety and Security, prepared [illegible] 2) GEN-SOP-002, Cord Blood Receipt and Hand[ling] [illegible] 3) GEN-SOP-003, Clean Room Operating and Maintenance Protocol, prepared 3/28/18 4) GEN-SOP-004, Purification of Hematopoietic Progenitor [illegible] prepared 4/2/18. 5) SOP: Product Recall/Adverse Events, prepared 5/24/18 F. Incoming supplies used during aseptic processing [illegible] analysis or other acceptance criteria before use. [illegible], sterile [illegible] spray bottles, sterile: [illegible] used during aseptic processing within the:
- Observation 5
Aseptic area environmental deficiencies
ITEM 5 Aseptic processing areas are deficient regarding the system for [illegible] A. There are no written environmental monitoring procedures. Environmental monitoring has been done once (May 2018), since operations began in mid-2017. [illegible] monitoring will begin being performed once every 2 [illegible] B. There is no gowning procedure. And there has been no personnel monitoring.
- Observation 6
Batch records missing step documentation
ITEM 6 The batch production and control records are deficient in that they do not include documentation of accomplishment of each significant step in processing. Specifically, the aseptic processing steps described in GEN-SOP-004 (Purification [of] Stem Cells from Human Umbilical Cord Blood) are not documented to assure all steps were performed as directed. For example: that the proper amount of [illegible] were performed, proper amount of [illegible] were added, proper incubation times and temperatures were performed, and proper controlled rate freezing was performed. On 6/20/18, I observed aseptic processing of donor [illegible]; labeling of the vials as instructed in step P, HJ of GEN-SOP-004 was not done.
- Observation 7
No process validation/control procedures
ITEM 7 Control procedures are not established which validate [illegible] be responsible for causing variability in the characteristics of [illegible]. Specifically, the aseptic process used to manufacture umbilical cord bl[ood] have an established incoming bioburden of collected umbilical [illegible] the cryopreserving agent.
- Observation 9
Cleaning process not validated
ITEM 9 Aseptic processing areas are deficient regarding the system to produce aseptic conditions. Specifically, the cleaning process has not been validated. A. There was no data or rationale provided to determine the se[lection] to clean the room and [illegible] I used (b) (4). B. There was no information on whether the cleaning records do not document whether dilutions or contact times occurred.
- Observation 10
Distribution records missing
ITEM 10 Distribution records do not contain the name and address of consignee and date and quantity shipped. Specifically, there are no distribution records.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCBER · BiologicsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013306140 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013306140. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.