Innoveix Pharmaceuticals Inc

3790 Arapaho Rd, Addison, Texas, United States

FEI 3012907473

FDA has 2 inspections on file for Innoveix Pharmaceuticals Inc in Addison, Texas (FEI 3012907473), from 2019 to 2021. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER · Office of Pharmaceutical Quality Operations, Division II).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2019–2021
2 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
↗
2 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Use of non-pharmaceutical component

      OBSERVATION 1 The [(b)(4)] intended to render final product sterile [illegible] Specifically, Your firm's Pharmacist in Charge (PIC) uses a non-pharmaceutical grade injectable drug preparations that are [(b)(4)] subcutaneously or intramuscularly. On 05/12/2021, I observed the PIC use a sterile non-pharmaceutical grade Sermorelin/Ipamorelin 3mg Injection Solution, Lot SIP225. In addition [illegible] performed and your firm has not conducted [(b)(4)].

    2. Observation 3

      Unvalidated sterilization/cleaning

      OBSERVATION 3 [(b)(4)] is not sterilized by routine sterilization cycles and cleaning process. Specifically, Your firm's Pharmacist in Charge (PIC) does not know whether or not the [(b)(4)] sterile injectable drug products has a sterilization, sanitization and/or clean in place cycle. PIC stated that he uses sterile [(b)(4)] wipes to clean [illegible].

    Show observations 4 to 8
    1. Observation 4

      Media fills not representative

      OBSERVATION 4 Failure to conduct media fills that closely simulates aseptic production under challenging and stressful conditions. Specifically, Your firm's Pharmacist in Charge (PIC) routinely compounds [illegible] per batch. According to your PIC, firm's smallest batch size [illegible]. However, your media fill consists of a total of [illegible] [(b)(4)] step in your media fill process.

    2. Observation 5

      Improper vial wrapping/sterility risk

      OBSERVATION 5 Glass vials intended to be sterile and [(b)(4)] were inadequately wrapped with foil and was observed. Specifically, On 5/11/2021, I observed your firm's Pharmacist in Charge (PIC) [illegible] were sterilized and [(b)(4)] in the [(b)(4)]. The vials were loosely wrapped with tin foil that the sides [illegible]; wrapped trays do not ensure that the vials are protected. Loosely wrapped trays were placed in the [(b)(4)].

    3. Observation 7

      Non-pharmaceutical detergent used

      OBSERVATION 7 Your firm uses a non-pharmaceutical grade detergent [illegible] your compounded sterile [(b)(4)] injectable drug [illegible]. Specifically, Your firm uses a household detergent, [(b)(4)] for beakers and glass rods that are routinely used in injectable drug products. You have not established removal of residues from your glassware.

    4. Observation 8

      Inadequate sterilizer cycle parameters

      OBSERVATION 8 The cycle parameters (temperature, pressure and [illegible]) for sterilization were not lethal to heat-resistant microorganisms. **Repeat Observation** Specifically, 1. Your firm uses the [(b)(4)] to sterilize [illegible] in the preparation of your firm's sterile injectable drug products. Endotoxin indicators to ensure and verify that the [(b)(4)] glassware is adequate are not used. 2. Your firm uses [(b)(4)] to sterilize rubber [illegible] used in the preparation of your firm's sterile injectable drug products. You do not verify and ensure that the temperature, time and pressure cycle used to sterilize the equipment is adequate.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Sterile product exposed to poor air

      Un-protected product intended to be sterile was exposed to low processing area quality air. Specifically, Your firm's Pharmacist-In-Charge left vials (b) (4) Units, Lot #INX575, Production Date 07/26/2019, inside your (b) (4), model (D) (4), pending sterility testing results. Your firm's Pharmacist-In-Charge executes all capping and crimping of your ISO 5 biosafety cabinet. Your firm caps and crimps sterile drug products area of the general pharmacy.

    2. Observation 2

      Poor-quality air influx to ISO area

      Your facility design allowed the influx of poor quality air into a higher classified area. Specifically, On 08/27/2019, I observed your firm's ISO 5 area to be a HEPA filtered area outside [illegible] cabinet and your ISO 5 area is separated from the ISO 7 (b) (4) pressure between the ISO 5 areas and the ISO 7 I.V. Buffer area. Your firm only monitors pressure differentials between the ISO 7 I.V. Buffer area, your ISO 8 Anteroom, and the general pharmacy area. Your firm's third-party ISO 5 environment qualification company, does not perform smoke studies under dynamic conditions for any classified areas at your facility, including your ISO 8 Anteroom, ISO 7 Buffer area, and most importantly your ISO 5 biosafety cabinet. your facility's ISO 5 environments are characterized, in order to prevent influx your higher classified areas. In addition, your firm turns off the airflow in your biosafety cabinet, brand name (b) (4), serial number (b) (4), while not in use. This allows for potential [illegible] air into your biosafety cabinet's higher classified environment. Your [illegible] intended to be sterile in your biosafety cabinet failed sterility testing on 05/15/2018 due to exceeding maximum air fungal counts, 08/04/2017 due to exceeding maximum air fungal counts, failure on 01/01/2016 for your drug product, Sermorel

    Show observations 3 to 8
    1. Observation 3

      Gloved hands touched non-ISO5 surfaces

      Personnel touched equipment or other surfaces located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing without sanitizing gloves. Specifically, On 08/28/2019, during the production of Human Chorionic Gonadotropin, Production Date 08/28/2019, your firm's Pharmacist-In-Charge touched an exterior alarm switch eight times (located on front of the biosafety cabinet), with gloved hands, and failed to disinfect his gloved hands prior to reentry into the ISO 5 biosafety cabinet. In addition, the firm's Pharmacist-In-Charge rested his arms on the front of the ISO 5 biosafety cabinet during production.

    2. Observation 4

      Insufficient disinfectant contact time

      Disinfectant contact time (also known as "dwell time") and coverage insufficient to achieve adequate levels of disinfection. Specifically, On 08/27/2019, your firm failed to allow adequate contact times for [the] cabinet, brand name (D) (4), model (D) (4), environment. Your firm's Pharmacist-In-Charge allows for a contact time inconsistent with the manufacturer's cleaning agent, (D) (4). The manufacturer's sporicidal activity for (b) (4) is (o) (4) [illegible].

    3. Observation 5

      Equipment not disinfected before use

      Equipment was not disinfected prior to entering the aseptic processing area. Specifically, On 08/28/2019, your firm's Pharmacist-In-Charge failed to adequately disinfect equipment prior to entering your biosafety cabinet. Your firm's electric connection cable to the repeater pump, brand name (b) (4), serial# (b) (4), was disinfected in the ISO 7 I.V. Buffer Room area, but was dragged on the ISO 7 I.V. Buffer Room's floor into the ISO 5 area prior to entry. This cable was not disinfected prior to entry into the firm's biosafety cabinet, during the production of Human Chorionic Gonadotropin, (b) (4) Units, Lot # [illegible].

    4. Observation 6

      Improper gowning technique contaminating

      Personnel donned gowning apparel improperly, in a way that may have caused the gowning to become contaminated. Specifically, On 08/28/2019, your Pharmacist-In-Charge failed to properly don the sterile gown and execute proper aseptic technique. While sterile gowning, the gown's arm sleeves and head hood tied to touch the floor of the anteroom and materials staging tables in the anteroom. This was prior to the production of Human Chorionic Gonadotropin, Lot SIM580, Production Date 08/28/2019. Your firm's PIC placed his head inside the biosafety cabinet without disinfecting it. Your firm's PIC placed his head inside the biosafety cabinet during set up of the repeater pump.

    5. Observation 7

      Particle-generating debris in ISO5 area

      The ISO 5 classified aseptic processing areas had particle-generating materials on the surface. Specifically, On 08/27/2019, your firm failed to adequately clean your biosafety cabinet, brand name [illegible], model [illegible], serial number (b) (4). The Pharmacist-In-Charge left empty syringes, vials, gloves, syringe wrappers, sterile wipe wrappers, and an open bottle of water in your biosafety cabinet overnight. Additionally, your firm's Pharmacist-In-Charge [illegible] overnight. This [illegible] utilized [illegible] into your I.V. Buffer Room (ISO 7 classified) and then further transferred [illegible] classified environments.

    6. Observation 8

      Insufficient anteroom space for gowning

      Your facility was designed and/or operated in a way that permits potential contamination. Specifically, On 08/28/2019, I witnessed your firm's lack of adequate space in your anteroom area to allow the Pharmacist-In-Charge to properly sterile gown and stage materials prior to the production of Human Chorionic Gonadotropin, (b) (4) Units, Lot # SIM580, Production Date 08/28/2019. I observed your firm's PIC touching items and surfaces in the ISO 8 anteroom without gloves.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3012907473 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3012907473. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.