Northern VA Compounders PLLC
23475 Rock Haven Way Ste 105, Sterling, Virginia, United States
FEI 3012590153
FDA has one inspection on file for Northern VA Compounders PLLC in Sterling, Virginia (FEI 3012590153). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER · Office of Pharmaceutical Quality).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 9 citations from this inspection. They are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2022
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Warning letters
- · CDER · Office of Pharmaceutical Quality ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Inadequate filter, final product sterilization
The filter intended to render final product sterile was not pharmaceutical grade.
- FDCA 501(a)(2)(A)
Cleanliness, ISO-classified areas
The ISO 5 classified aseptic processing areas had difficult to clean, particle-generating and visibly dirty equipment or surface.
- FDCA 501(a)(2)(A)
Inadequate HEPA filter, sterile product area
You had inadequate HEPA filter coverage and airflow over the area to which sterile product was exposed.
- FDCA 501(a)(2)(A)
First pass air blockage, open unit with sterile product
Personnel conducted aseptic manipulations and placed equipment/supplies in an area that blocked the movement of first pass air around an open unit, either before or after it was filled with sterile product.
- FDCA 501(a)(2)(A)
Beta-lactam drugs, inadequate sanitation
You produced beta-lactam drugs without providing adequate containment, segregation, cleaning of work surfaces, cleaning of utensils and cleaning of personnel to prevent cross-contamination.
Show 4 more citations
- FDCA 501(a)(2)(A)
Use of non-pharmaceutical grade components
You used a non-pharmaceutical grade component in the formulation of a drug product.
- FDCA 501(a)(2)(A)
Hazardous drugs, prevention of cross-contamination
You produced hazardous drugs without providing adequate cleaning of work surfaces to prevent cross-contamination.
- FDCA 501(a)(2)(A)
Non-microbial contamination, production area
Non-microbial contamination was observed in your production area.
- FDCA 501(a)(2)(A)
Improper gowning, contamination
Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Office of Pharmaceutical Quality · DrugsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012590153 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012590153. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.