Skip to content

Global Pharma Healthcare Private Limited

A - 9 Sidco Pharmaceutical Complex, Thiruporur, Chennai, India

FEI 3012323885

FDA has one inspection on file for Global Pharma Healthcare Private Limited in Chennai, India (FEI 3012323885). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below.

FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2023
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
66-40Red List
Matched on FDA’s firm name and street address

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Unvalidated sterilization and aseptic process

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, A. You aseptically fill the EXER mg/mL to manufacture for the US market. You intend to achieve the sterilization of the drug product through filtration on a filter for sterilization. There is not adequate validation data to demonstrate that the PYRE and the accompanying filter housing and equipment can reliably sterilize the EYRE solution. In addition, you have not established that the sterilization process is effective across different manufacturing conditions such as the pH and temperature of the solution, filtration pressure, flow rate, maximum filtration time, batch size (volume) and effect of [N@)sterilization on the filter’s retention capability. You have also not established the worst-case scenario for the bioburden. Your General Manager of the Quality Assurance stated that a controlled filling room temperature ba °C) established the filtration temperature, and the passing assay of the drug product confirms the filter compatibility. According to your Manufacturing process flow chart, you REE EIR filter for the manufacturing of EARN for the US market. However, your (master) Batch Manufacturing Record Doc. No. BMR/CMC/001 Effective date 9/28/2020 includes al lr (this s really the BY filter as per your General Manager QA). You have entered SOP No. BX) SOP-SFU-EEN-018-01 Filter Integrity Test for PHAN Filters in EXANEI Section (Effective date 1/30/2021) and SOP No. SOP-SFU-EEN-019-01 Filter Integrity Test for BN Filters in mi msOERe EE (Effective date 1/30/2021) in wet ink in the executed BMRs, e.g., Batch No’s The BMRs for the batches Your General Manager of the Quality Assurance stated that the pressure psi) recorded for the BI or here WEEE manufacture all @fbatches that were shipped to the US market. No explanation was provided for why the opening balance of EIEN filters for years 2021 and 2022 was Bl despite documented usage. Purchase order reconciliation of filters could not account for any quantity of PCT filters Lot No. CIR balance balance EN filer fot @batches [a El [6 _©Nfilter fof Bbatches. You did not have purchase order or any document to verify that EI filters Lot No. BYR was procured at your facility. Your QA manager stated that filters are considered consumable items and are not recorded in the warehouse entry register. B. You conducted filter integrity test (FIT) for the PNR filter by pressure hold method: BYE) The pressure and hold time used for FIT are not validated and are not documented in a procedure. You have not recorded the equipment IDs of the pressure gauges used for the FIT in the BMRs. Your General Manager of Quality Assurance stated that the SOP No. BI#I SOP-SFU-EEN-018-01 Filter Integrity Test for EIN Filters in ARIE Section (Effective date 1/30/2021) noted in the BMRs is not actually for the FIT for the This procedure describes FIT Tim ee a ote pressure and E@FNof hold time. C. You do not perform container closure integrity test (CCIT) for the drug products. Your General Manager QA stated that fer (RASAESRERES Ey is filed in an EAI bottle and solution is not visible. Because of this, a manual visual inspection is the only test to detect any leak. There is no assurance or documentation that this visual inspection can detect aseptic barrier issues with the container or closure. You used a manufacturing process that lacked assurance of product sterility. You used this deficient manufacturing process to manufacture (llbatches of [El between December 2020 and April 2022 and shipped these batches to the US customer. The batches shipped to the US customers include: Batch No’s| units for @)batches, Expiry date Batch No's| units Be Expiry date RIT Batch Lowa its for ggy batches, Expiry date BIT. D. Deficiency in formulation of rug products was observed. Specifically, Sterile EO and 2 Ointment did not contain preservatives to prevent

      Shortened here; the PDF has the full text.

    2. Observation 2

      Test method suitability not established

      The accuracy, sensitivity, specificity, reproducibility, of test methods have not been established. Specifically, A. The sterility method suitability testing for your firm’s [BNI and CYR Ointment did not meet the protocol acceptance criteria. Your firm lacked sterility assurance for the above drug products distributed to the U.S. market. Specifically, a. Analytical Method Verification Protocol for Sterility Test — ENN Protocol No. STVP/2019/004, requires that for product positive control, clear visible growth of microorganisms should be obtained after incubation. However, the positive product control test was not performed during method suitability validation. b. Analytical Method Verification Protocol for Sterility Test — Sterile BX#]Ointment, Protocol No. STVP/2020/002, requires that for product positive control, clear visible growth of microorganisms should be obtained after incubation. However, the positive product control test was not performed during method suitability validation. B. The sterilization of PYAR Ointment batch BYE) by EXER method was not validated. Batch BJ) was manufactured in December 2020 for the U.S. market. Your firm lacked sterility assurance for the above drug product distributed to the U.S. market.

    Show observations 3 to 6
    1. Observation 3

      Filling machine design/performance issues

      Equipment used in the manufacture, processing, packing, or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, Filling Machine ID # BYR FL.M/113 is used for the manufacturing of for the US customers. The machine fills Bm of mg/mL in an BIA Grade bottle o diameter and height. The (master) Batch Packing Record Doc. No. BPR/CMC/001 Effective date 9/28/2020 does not have filling speed. The design qualification confirmed that the machine is designed to fill fm flo BRmL SNE bottles EAN speed in a bottle of © imm i height; outside the Specification of the bottle used for [EYENTTIIN (OXI mm height) and the fill volume. The performance qualification was determined to be acceptable, however, no data for the batches that were used for test runs was included in the PQ Report.

    2. Observation 4

      Inadequate cleaning and sterilization controls

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions. Specifically, A. On 2/23/2023, Assistant Manager of Quality Assurance stated the EI effectiveness study has not been carried out for the Unit sterile Manufacturing Block where @IAFTIN is manufactured for the US market. As per your procedure SOP No. [BY SOP/SFU/EEN-008-0 Procedure for [EXER for in EYER Plant (Effective date 1/29/2021), you carry out BIER of clean area (including filling room) before resuming the production and after a BX or air handling unit is not under operation for more than BY In addition, you have not established the ETT EEO phase times for the BJA Hence, there is no assurance that [EYER with docs no cross contaminate aseptically filled products. E.g., according to the filling machine equipment use log, you carried out EIN on 4/10/2022 Fon ®@ OE, after you started filling for EAR Batch No. BIEN (filling on 4/10/2022). However, in the batch record you have noted filling timing 4/1 12022808 Pom. Your production manager did not have any explanation for the discrepancy between the equipment use logbook and the batch packing record. On 2/28/2023, your Microbiologist shared Validation Protocol to Determine the Duration of ENON Effectiveness No. BI DFEP/001/00-23 Effective date 1/11/2023 and corresponding report No. BIR DFER/001/00-23 to verify the conducted OX Al effectiveness study. The report lacks the location/rooms of the study, number, and locations of the microbial indicators, and is missing the signature dates for the reviewers and approvers. Your Microbiologist who carried out the BI&El study could not remember the room number where he carried out the [BIE study. B. Your cleaning process for the Unit sterile manufacturing area is deficient such that the cleaning record does not include cleaning of several areas of the room including but not limited to; doors, handles, and HEPA filter grills. The cleaning is documented on Format No. BJ) PRD-GEN-002-F-001-00 but this corresponds to procedure [BYE SOP-PRD-GEN-002-0 Procedure for Cleaning and Maintenance of the Manufacturing Areas (Tablets, Capsules, B®) Liquid, and BY Preparations) (Effective date 4/15/2021), which is not for the Sterile Unit. Your General Manager QA stated that the cleaning of the Unit sterile area is carried out as described in procedure PY SOP-SFU-FFS-005-02 General Cleaning Procedure for Sterile Formulation Plant (Effective date 2/3/2021). This procedure uses a [OYE system for cleaning and does not include BIN. The procedure lacks instruction for cleaning and sanitizing the surfaces. You have also not validated the effectiveness, contact times for the cleaning agents for various surfaces. C. Surfaces that contact EIEN container-closures were not cleaned, sanitized, decontaminated, or sterilized, and there were no written procedures indicating any such activities should be performed. Specifically, your firm does not have SOP(s) for the cleaning and sterilization of the Unit [ON EIOIN Fill Line bowls used for the dispensing of EIEN bottles, BY#caps, and PY@) caps which were all product contact surfaces. The @J Fill Line is located in Filling Room ®ER and used to aseptically fill IER for the U.S. market. D. [BIER Unit Preparation ID# SS/UPA/087 lacked load pattern and sterilization cycle validation. Specifically, The above BIEN was used for the sterilization of, for example, filling nozzle, [BYE tubing, BIO containers, B® bottles, bowls for sterile container-closure, tools, other change parts, and cleanroom garments, used for Unit EIN Fill Line aseptic filling activities. However, your firm lacked load pattern validation to ensure successful sterilization was achieved.

    3. Observation 5

      Failure to verify component identity/suppliers

      Your firm failed to conduct at least one test to verify the identity of each component of a drug product. Your firm also failed to validate and establish the reliability of your component supplier’s test analyses at appropriate intervals. Specifically, A. Active pharmaceutical ingredient (API) BX was used in the manufacturing of EIEN. Your firm failed to test incoming BXAF to determine conformance to identity, purity, strength, and other appropriate specifications. Instead, you released API for use in drug production based solely on certificates of analysis (COA) from your supplier without establishing the reliability of the supplier’s analysis through appropriate validation and ensuring that at least one specific identity test is conducted for each lot. B. Your firm failed to qualify the supplier for excipient EHNI used in the manufacturing of

    4. Observation 6

      No validated cleaning/maintenance procedures

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, A. You manufacture sterile ES 2 nL) for the US market in non-dedicated equipment in Unit sterile Plant where you also manufacture I or Miya and OY for Myanmar and Ethiopia. You have not validated the cleaning procedure for the manufacturing equipment including but not limited to: OYE vessel (ID # BIARINIMAV/108), filtration tank (ID# OXON FL T/110), and filling machine (ID # OMAN FLM/113). Instead, your QC manager stated that the firm analyzed the rinse samples collected after cleaning the manufacturing equipment to test for the last drug products against a specification for NMT Blppm by UV method. However, it was also stated that the test method to analyze the swab sample for low levels (sub ppm level) of drug substances was not validated and LOD and LOQ were not established. As a result, there is no analytical assurance that the cleaning procedure prevents cross contamination on this non-dedicated equipment. On 4/7/2022, you manufactured OX mg/mL Batch No. SX right after manufacturing CYR Batch No. on 4/3/2022. However, cleaning verification of the manufacturing equipment after manufacturing involved testing the rinse for the YT and not for the BURT. B. On 2/21/2023, during walkthrough of the filling room in Unit I, FDA observed a black, brown colored greasy deposit on the bottle transfer ENN bowl, which is part of Filling Machine ID # YARN FLM/113. The brownish material deposition on the bowl was confirmed by wiping the surface of the container with a blue lint free cloth. The portion of the lint free cloth that was rubbed against the black, brown surface of the bowl revealed brown spots. According to the equipment use logbook, the filling machine was last cleaned on 1/31/2023 after manufacturing @J& Batch No. BYR and has not been used since. On 2/27/2023, your Production Manager stated that there was no procedure for cleaning the Filling Machine ID # [PYRIIIFL.M/113. He stated that there was no space to store dirty and clean equipment in Unit Sterile Plant. After completion of the batch, the filling machine accessories are taken out for cleaning. After cleaning, the accessories are re-fixed immediately to the filling machine. Before starting the production, all the filling machine accessories are taken out and [PY and re-fixed to

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov

    Date published 2023-01-03

    FDA’s entry
    Global Pharma Healthcare Private Limited · A - 9 Sidco Pharmaceutical Complex, Thiruporur, Chennai, Tamil Nadu INDIA
    FDA’s inspection record for FEI 3012323885
    Global Pharma Healthcare Private Limited · A - 9 Sidco Pharmaceutical Complex, Thiruporur, Chennai, India

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    10 products

    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 56 - - - --Antibiotics (Human/Animal)
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    Show 7 more products
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3012323885 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3012323885. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.