Valisure, LLC
5 Science Park, New Haven, Connecticut, United States
FEI 3012063246
FDA has one inspection on file for Valisure, LLC in New Haven, Connecticut (FEI 3012063246). It ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Jul 6, 2022 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2021
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 2 requests, latest Jan 27, 2022
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate method validation/verification
The firm failed to adequately validate and/or verify analytical methods used in the evaluation of pharmaceutical products in that the firm failed to document the validation/verification process, acceptance criteria, and an evaluation of the validity of the method outlining its intended use. For example, (A). Inductively Coupled Plasma Mass Spectrometry (ICP-MS Test) PR-021 R1 (Verification of USP <233> Elemental Impurities): (a). Method Verification did not include justification for the removal of contaminants by (b) (4) [illegible]. Furthermore, there is no mention of [illegible]. (b). Method Verification did not include an evaluation of the sample (b) (4) for a variety of pharmaceutical dosage forms (i.e., capsules, liquids, semi-solids). (c). Method Verification did not include accuracy, precision, specificity, limit of quantitation, range, and linearity. (d). Method Verification did not include the outlined system suitability criteria. Furthermore, the ICP-MS Test does not include the USP <233> system suitability requirement prior to analysis. (e). On 01/13/2021, the firm had analyzed a sample of (b) (4) for Elemental Impurities, the laboratory identified an Out-of-Specification result for Lead at 17.749 ppb (1.7 μg lead/tablet, maximum adult dose 13.6 μg lead/day) exceeding the firm's specification of (b) (4). On 01/14/2021, the firm had re-analyzed this sample in triplicate using a new sample preparation using (b) (4). The analysis confirmed the Lead results at 17.0 ppb. This process of using (b) (4) in order to rule out lead contaminated glass was not verified and/or validated. (B). Gas Chromatography Mass Spectrometry (GC-MS) Impurity Test - Nitrosamines PR-018 R4 (Verification of U.S. FDA Method: Combined N-nitrosodimethylamine (NDMA) and Nitrosodiethylamine (NDEA) Impurity by (b) (4) in Valsartan Drug Substance or Drug Product): (a). Method Verification was performed on the Valsartan Drug Product for NDMA and NDEA impurities; however, the current method, PR-018 R4 is used to analyze a variety of drug products and dosage forms for the following impurities: NDMA, NDEA, N,N-Dimethylformamide (DMF), N-Nitrosoethylisopropylamine (NEIPA), N-Nitrosodiisopropylamine (NDIPA), and N-Nitrosomethylethylamine (NMEA). There was no documented validation process for analyzing the additional impurities on other drug products. (b). Method PR-018 R4 contains no system suitability requirement as outlined within the FDA Method, which states the correlation coefficient (R) of the linear calibration curves should be ≥ 0.995. (C). Liquid Chromatography High Resolution Mass Spectrometry (LC-HRMS) Impurity Test PR-020 R1, which is a Verification of U.S. FDA Method: Liquid Chromatography - Electrospray Ionization - High Resolution Mass Spectrometry (LC-ESI-HRMS) Method for the Determination of Nitrosamine Impurities in Metformin Drug Substance and Drug Product: (a). Method Verification was performed on Metformin Drug Product for impurities NDMA, NDEA, NMBA, NEIPA, N-nitrosodibutylamine (NDBA), DMF and N,N-diethylformamide (DEF); however, the FDA method only listed the following impurities NDMA, NDEA, NEIPA, NDIPA, NDPA, NMPA, NDBA and NMBA. There was no documented validation process for analyzing the additional impurities on other drug products. (b). There was no validation/verification report as of the time of the inspection (May 26, 2021). The method has been routinely used since its approval on 3/5/2020. (c). Method PR-020 R1 contains no system suitability requirement as outlined within the FDA Method (%RSD of peak area for each nitrosamine impurity for the first six injections NMT 10% and cumulative %RSD of the peak area for each nitrosamine impurity NMT 15%). (D). Gas Chromatography Mass Spectrometry (GC-MS) Impurity Test - Residual Solvent PR-024 R0, which is a Verification of U.S. FDA Test Method: Direct Injection Gas Chromatography Mass Spectrometry (GC-MS) Method for the Detection of Listed Impurities in Hand Sanitizers; and USP <4
Shortened here; the PDF has the full text.
- Observation 2
Inadequate equipment qualification program
The firm's equipment qualification program is inadequate. For example, The following instrumentation used in analytical testing of pharmaceutical drug products have not been fully qualified. Instrument Name Manufacturer Model Number ID Number (b) (4) (b) (4) (b) (4) (a). The firm failed to perform or document IQ/OQ/PQ on their (b) (4). In addition, the firm did not establish an IQ/OQ/PQ protocol. The (b) (4) are used to perform NDMA, NDEA, DMF, and Benzene analytical testing. (b). The firm failed to perform PQ for their (b) (4) used in Elemental Impurities Testing. (c). The firm failed to perform OQ/PQ for their (b) (4). Additionally, the Quality unit did not sign off on the IQ "Installation and Customer Familiarization Procedure" and failed to have documentation that the IQ was assessed. The (b) (4) is used to perform NDMA, NDEA, NDIPA, NEIPA, NMBA, NDBA, DMF, and DEF analytical testing. (d). The firm failed to establish a requalification frequency for their (b) (4) since original installation in 2019. The (b) (4) is used to perform Dosage Testing.
Show observations 3 to 6
- Observation 3
Uncontrolled instrument data access
The firm has failed to adequately control data access within analytical equipment used for the analysis of pharmaceutical products. For example, The (b) (1), (b) (4), (b) (4), and the (b) (4) have no controlled access (i.e., no passwords required). Furthermore, each analyst has administrative access to these systems.
- Observation 4
Inadequate laboratory investigations process
The firm's laboratory investigations are inadequate. For example, The firm's process for laboratory discrepancies and investigations is inadequate in the fact that the firm has had at least 45 out-of-specification events and failed to perform any documented investigations from 06/07/2019-06/02/2021. In addition, the firm does not have an SOP instructing an employee to open an investigation when products do not meet their specifications.
- Observation 5
DSCSA systems and suspect product controls
Drug Supply Chain Security Act There are no systems in place to enable compliance with the requirements of the Food, Drug, and Cosmetic Act Section 582(c)(A) & (B) and (d)(A) & (B). Your firm has none of the verification systems required by the Drug Supply Chain Security Act (DSCSA). When asked, your firm stated that it had not previously heard of the DSCSA. Specifically, (a). Valisure has operated a pharmacy and wholesale distributor business which places them within the DSCSA definition of a trading partner (dispenser and wholesale distributor) and subjects them to the applicable requirements for those trading partners in the DSCSA. Under the DSCSA, covered product in the possession or control of a wholesale distributor or dispenser which is determined by that person to be a suspect product must be placed into quarantine and not processed further until a determination is made that the product is either cleared or illegitimate. In addition, when a product is determined to be a suspect product, prompt investigations must be conducted in coordination with trading partners, including validating the transaction history and transaction information. There is no documentation demonstrating that your firm appropriately identified products potentially subject to rejection by your laboratory as suspect products in your system(s). Examples include but are not limited to the following products: Bupropion XL lot NB900240 and Metformin lot MTSB19003-A. This Metformin lot was tested in September 2019. When the test results indicated that the lot may be rejected by the Valisure laboratory, your firm decided to reverse distribute the lot. In these examples, when initial laboratory testing showed that product potentially could be subject to rejection by your laboratory, your firm determined such product to be a suspect product when it concluded there was reason to believe that the product was unfit for distribution. In these situations, and others, your firm failed to coordinate with trading partners and conduct a robust investigation. In addition, your firm has no systems in place for determining and identifying a product as a suspect product in your system(s), and for quarantining and investigating suspect products generally. (b). Your firm could not provide documentation that product rejected by the Valisure laboratory was appropriately identified as illegitimate in your system(s) and that the DSCSA verification requirements were complied with. Examples include but are not limited to the following products: Valsartan lot EVF804A and Metformin lot AM180405A. When additional testing by your lab resulted in Valisure's rejection of the lots, the lots at issue were identified as illegitimate because your firm had credible evidence that such product was unfit for distribution. Your firm was then required to make a determination, in coordination with the manufacturer, that the suspect products were illegitimate. Your firm was unable to provide evidence that the lots were appropriately identified as illegitimate in your system or that you sought to coordinate with the manufacturer on making the determination that those products were illegitimate. In addition, there is no documentation demonstrating that your firm has systems in place to identify illegitimate product in your system(s), and for quarantining and dispositioning illegitimate products generally. (c). Trading partners must also have systems in place to retain samples of illegitimate product at the request of the manufacturer or FDA. Your firm indicated that Valisure has no such procedures.
- Observation 6
Failure to notify about illegitimate product
Trading partners must have systems in place to make a notification of illegitimate product to FDA and immediate trading partners within 24 hours after making such a determination. There is no documentation to indicate that your firm has such procedures. Furthermore, your firm failed to make timely (within 24 hours) notifications to immediate trading partners or FDA once your firm became aware that it was in possession of an illegitimate product. Specifically, (a). Your firm did not notify FDA within 24 hours after tests confirmed that product in your possession or control would be rejected by Valisure and was illegitimate product. Your firm has not filed nor submitted the required FDA Form 3911 "Drug Notifications" via the established FDA mailbox in such cases. Examples include but are not limited to Metformin lot AM180405A and Valsartan lot EVF804A. (b). While your firm did notify some manufacturers when certain lots were rejected by your laboratory, your firm failed to identify such drug product as illegitimate in those notifications. In addition, your firm failed to notify the wholesale distributors from whom Valisure acquired the product within 24 hours after tests confirmed that product in your possession or control was illegitimate product. Examples include but are not limited to Metformin lot AM180405A and Valsartan lot EVF804A. (c). After (b) (4) were conducted on Metformin lot AM180405A on February 23, 2020, the product was rejected by your laboratory for containing levels of NDMA above the acceptable (1:X) [illegible]. At that time, your firm decided that the lot would not be dispensed or distributed and that it was to be sent to a reverse distributor. Your firm notified the manufacturer of the rejected Metformin lot in a March 2, 2020 letter but did not notify the manufacturer that the product was illegitimate product under the DSCSA. FDA was made aware of the issue with the product through a citizen's petition your firm filed with the Agency on March 2, 2020, rather than the required FDA Form 3911 for reporting illegitimate products to FDA. The citizen's petition did not identify the product as an illegitimate product. The wholesale distributor from whom your firm purchased the lot was effectively notified at the same time and in the same manner as FDA.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Jan 27, 2022.
Inspection ending Jul 6, 2021OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Nov 10, 2021FDA-FOIA-2021-7730Form 483Closed
Inspection ending Apr 28, 2021
1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.
- Jan 27, 2022FDA-FOIA-2022-649EIRClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012063246 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012063246. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.