Skip to content

Reliant Compounded Solutions Monroe, LLC

810 Main St, Monroe, Connecticut, United States

FEI 3012039582

FDA has 3 inspections on file for Reliant Compounded Solutions Monroe, LLC in Monroe, Connecticut (FEI 3012039582), from 2017 to 2023. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published 3 citations from this inspection. They are listed below. One FOIA request has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Aug 29, 2019. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

One regulation was cited at more than one inspection: FDCA 501(a)(2)(A).

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2017–2023
2 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
4 posted
Requested under FOIA
1 request, latest Oct 17, 2023
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Personnel moving quickly, disrupting unidirectional airflow

      Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow.

    2. FDCA 501(a)(2)(A)

      Exposed to lower quality air/ISO 5

      Sterile drugs were exposed to lower than ISO 5 quality air.

    3. FDCA 501(a)(2)(A)

      Inadequate smoke studies

      Smoke studies were inadequately performed under dynamic conditions.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Inadequate sporicidal agents, cleanroom and ISO 5 area

      The use of sporicidal agents in the ISO 5 classified aseptic processing area was inadequate.

    2. FDCA 501(a)(2)(A)

      Non-microbial contamination, production area

      Non-microbial contamination was observed in your production area.

    3. FDCA 501(a)(2)(A)

      Inadequate HEPA filter, sterile product area

      You had inadequate HEPA filter coverage and airflow over the area to which sterile product was exposed.

    4. FDCA 501(a)(2)(A)

      Beta-lactam drugs, inadequate sanitation

      You produced beta-lactam drugs without providing adequate cleaning of work surfaces and cleaning of personnel to prevent cross-contamination.

    5. FDCA 501(a)(2)(A)

      Location, ISO 5 classified area

      The ISO 5 classified aseptic processing area was located within a non-classified room (segregated production area).

    Show 4 more citations
    1. FDCA 501(a)(2)(A)

      Ceiling tiles, cleanroom

      Unsealed, loose ceiling tiles were observed in your cleanroom.

    2. FDCA 501(a)(2)(A)

      Cleanliness, ISO-classified areas

      The ISO 5 classified aseptic processing areas had difficult to clean, particle-generating and visibly dirty equipment or surface.

    3. FDCA 501(a)(2)(A)

      Use of non-pharmaceutical grade components

      You used a non-pharmaceutical grade component in the formulation of a drug product.

    4. FDCA 501(a)(2)(A)

      Disinfecting and cleaning agents, ISO 5 area

      Disinfecting agents and used in the ISO 5 classified aseptic processing areas were not sterile.

  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance3 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inappropriate personnel clothing

      Clothing of personnel engaged in the manufacture of drug products is not appropriate for the duties they perform. Specifically, the pharmacist observed producing Triple P 10/0.5/16.6 Injectable Lot No. 02232017@8 on 02/23/2017 donned a disposable, non-sterile lab coat, rated for working in an ISO7 environment, and sterile gloves without sterile sleeves. The pharmacist was observed to extend [illegible] forearms exposing the ISO 5 production environment and product to the non-sterile lab coat.

    2. Observation 2

      Deficient environmental monitoring

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically: A. Your environmental monitoring program is deficient in that you do not perform monitoring of your classified spaces, including your ISO 5 working space and of personnel on a daily basis, rather it is performed (b)(4) and (b)(4), respectively. This frequency is not sufficient to demonstrate conditions are consistently maintained. B. Your firm does not continuously monitor the pressure differentials in your ISO8, ISO7 and ISO5 sterile production space in order to demonstrate that conditions are maintained throughout the operation. For example, continuous monitoring was not observed during the production of Triple P 10/0.5/16.6 Injectable Lot No. 02232017@8 on 02/23/2017.

    Show observation 3
    1. Observation 3

      Ceilings not smooth/cleanable

      Aseptic processing areas are deficient in that ceilings are not smooth and/or hard surfaces that are not easily cleanable. Specifically, on 02/23/2017 during the production of Triple P 10/0.5/16.6 Injectable Lot No. 02232017@8, unsealed ceiling tiles were noted in your ISO7 cleanroom where your ISO5 (b)(4) are located, and chipped/peeling caulking was noted on the ceiling tile in the adjacent ISO8 ante-room where the (b)(4) of this Triple P lot: Papaverine HCL USP, Phentolamine (b)(4) Prostaglandin E1 (b)(4) occurred.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Oct 17, 2023. It asked for a Form 483.

  • Inspection ending Aug 23, 2023VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Oct 17, 2023FDA-FOIA-2023-9183Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3012039582 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3012039582. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.