Bhaumik Diversified LLC dba Texas Star Pharmacy
3033 W Parker Rd Ste 100, Plano, Texas, United States
FEI 3012032875
FDA has one inspection on file for Bhaumik Diversified LLC dba Texas Star Pharmacy in Plano, Texas (FEI 3012032875). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 12 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2021
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 12 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
No segregation for hazardous drugs
You produced hazardous and potent drugs without providing adequate segregation and cleaning of utensils to prevent cross-contamination. Specifically, Your firm routinely produces sterile and non-sterile drug products containing hormones such as Testosterone and Progesterone without appropriate controls to prevent cross-contamination from these hazardous and/or potent drug products. Your facility has no dedicated rooms, dedicated hoods, or dedicated equipment.
- Observation 2
Inadequate dynamic smoke studies
Smoke studies performed under dynamic conditions were inadequate. Specifically, Your firm's smoke study utilizing the [(I:>)(4)] failed to demonstrate unidirectional airflow over and away from the pharmacy technician due to the lack of smoke generation.
Show observations 3 to 12
- Observation 3
Inadequate media fill simulations
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most challenging and stressful conditions. Specifically, Your media fill kit on [illegible] vials of which [illegible] did not simulate production operations under the worst-case, most challenging and stressful conditions. The following sterile injectable products were produced by the firm: • On 8/11/2021, [illegible] aseptically filled vials, BUD: 12/09/2021. • On 10/08/2021, [illegible] aseptically filled vials, BUD: 02/05/2022. • On 10/14/2021, [illegible] aseptically filled vials, BUD: 04/12/2022.
- Observation 4
Insufficient disinfectant dwell time
Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection. Specifically, On 10/19/2021, I observed your sterile technician fail to follow the manufacturer's instructions for a sporicidal [(o)(4)] solution used to disinfect the surfaces of the ISO5 BSC that was being used to prepare Tacrolimus 0.03% Oil Ophthalmic Drops and/or Glutathione 200 mg/ml Injection, Lot #10192021@19, BUD: 02/15/2022. The manufacturer's instructions state that a [illegible] contact time is required to kill Clostridium difficile spores; however, the sterile technician only allowed a 2-minute contact time. In addition, there was no timer/clock located in the ISO5 BSC to adequately monitor contact times.
- Observation 5
Non-sterile items used in ISO areas
Use of non-sterile [(l:5)(4)] in ISO-classified areas. Specifically, On 10/19/2021, I observed the sterile technician compromise sterile practices by using non-sterile items in the ISO7 ante-room and in the ISO5 buffer area. The sterile technician removed the spray head from a commercially purchased bottle of [(I:>)(4)] in the ISO7 anteroom to disinfect the outside of totes containing items such as product and [(I:>)(4)]. The sterile bottle of [(I:>)(4)] was partially open to the ISO7 environment until the sterile technician used it to disinfect hands and equipment in the ISO5 BSC. The sterile technician also used non-sterile scissors and a non-sterile [6}]:iJ)] solution to disinfect or handle supplies before placement in the ISO5 BSC.
- Observation 6
Non-sterilized equipment in aseptic work
Non-sterilized equipment was used in sterile drug production. Specifically, On 10/19/2021, I observed your sterile technician use non-sterilized equipment during aseptic activities for Tacrolimus 0.03% Oil Ophthalmic Drops and/or Glutathione 200 mg/ml Injection, Lot #10192021@19, BUD 02/05/2022. Non-sterile scissors and non-sterile [6}]:iJ)] were stored exposed on a stainless-steel shelf where the ISO5 BSC is located.
- Observation 7
Failure to change/disinfect gloves
Personnel failed to disinfect or change gloves frequently enough. Specifically, On 10/19/2021, during the set up for aseptic activities for Lot #10182021@12, BUD: 02/15/2022 and Glutathione 200 mg/ml, I observed your sterile technician on two occasions fail to change gloves after touching the garbage can. The sterile technician proceeded to touch supplies (scissors) located on the stainless-steel shelf in the ISO7 buffer area and then placed gloved hands into the ISO5 BSC without disinfecting or removing gloves.
- Observation 8
Non-pharmaceutical grade components used
You used a non-pharmaceutical grade component in the formulation of drug products. Specifically, The following bulk drug substances were used in the formulation of drug products that are not compliant with approved drug components or a USP or NF monograph, not components of an FDA 503A bulk list: • [(6r(4)] Lot [(l:5)(4)], Exp: 04/02/23 was used in Kisspeptin-10 MDV 200 mcg/ml (5 ml) Injection, Lot #08112021@9, BUD: 12/09/2021. • (b)(4) I: Lot [(b)] used in [illegible] 5 mg/ml Injectable, Lot #05272021@4, BUD [illegible]. • [illegible] Lot #08202021@18, BUD: 12/18/2021. • [illegible] Lot [(t>H 4)] etc. These sterile injectable drug products made from non-pharmaceutical grade components were distributed to patients.
- Observation 9
Inadequate preparation of stock solutions
Stock solutions are not adequately prepared for prevention of microbial contamination. Specifically, Your Pharmacist stated that stock solutions are made [illegible] preparation and stored in the refrigerator until needed. Your firm prepared [(t>H 4)] Stock Solution, Lot [illegible], used to prepare approximately [illegible] batches of TRIMIX and QUADMIX drug products. Your firm prepared [(or(4)] Stock Solution, Lot [illegible], used in approximately [illegible] batches of QUADMIX produced drug product.
- Observation 10
Non-pharma grade detergent/disinfectant
You used a non-pharmaceutical grade detergent and a non-sterile disinfectant used in the production of sterile injectable and non-sterile drug products. Specifically, Your firm uses a commercial brand '(b)(4)' [(I:>)(4)] sterile disinfectant to clean equipment such as glassware used in the production of sterile and non-sterile drug products. There is no assurance that hazardous/potent drugs are absent from equipment and utensils used in the production of non-sterile drug products.
- Observation 11
Dirty utensils in non-sterile production
Visibly dirty utensils used in the production of non-sterile drug products. Specifically, On 10/21/2021, I observed several visibly dirty, discolored and rusted spatulas (with or without wooden handles) in a storage area used in the production of non-sterile drug products during the inspection of the laboratory.
- Observation 12
Visible non-microbial contamination
Non-microbial contamination was observed in your facility. Specifically, On 10/19/2021, the floor and door of your ISO7 processing and preparation room were visibly dirty with brown residue despite cleaning as stated by your Pharmacist.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012032875 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012032875. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.