Tri-Coast Pharmacy
14125 US Highway 1, Juno Beach, Florida, United States
FEI 3011827553
FDA has one inspection on file for Tri-Coast Pharmacy in Juno Beach, Florida (FEI 3011827553). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER). FDA has also posted a Form 483 dated Dec 23, 2016 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2016
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Microbial contamination in ISO 5 area
Observation 1: Actionable microbial contamination was present in the ISO 5 area or in adjacent areas during aseptic production without adequate product evaluation and remedial action. Specifically, on July 7, 2016 your firm detected high levels of gram-negative rods, coagulase positive staphylococcus, molds and yeast during routine Environmental Monitoring (EM) which is conducted every (b)(4) within the (b)(4). This is evident by the following examples: Location (b)(4) 5 cfus total: 3 cfus of coagulase-negative staph., 1 cfu of dermacoccus spp. and 1 cfu of bacillus spp. Location (b)(4) 5 )- 3 cfus total: 2 cfus of gram positive coryneform bacillus and 1 cfu of bacillus spp. Location (b)(4) - 4 cfus total: 3 cfus of micrococcus luteus and 1 cfu coagulase-negative staph. Location (b)(4) - 3 cfus total: 2 cfus of coagulase-negative staph. and 1 cfu of micrococcus spp. Location (b)(4) - 6 cfus total: 3 cfus of gram-positive coryneform bacillus, 2 cfus of coagulase-negative staph, and 1 cfu of bacillus spp. Location (b)(4) 5 4 )- 18 cfus total: 12 cfus of micrococcus luteus, 3 cfus of coagulase-negative staph., 3 cfus of acinetobacter radioresistens Location (b)(4) 29 cfus total: 23 cfus of micrococcus luteus, 3 cfus of micrococcus spp., 2 cfus of coagulase negative staph. and 1 cfu of acinetobacter radioresistens Location (b)(4) 5 4 )- 17 cfus total: 10 cfus of acinetobacter radioresistens, 3 cfus of micrococcus spp., 2 cfus of coagulase negative staph. and 2 cfus of bacillus spp. Location (b)(4) (Surface Samples) Location (b)(4) (b)(4) D-6 cfus total: 3 cfus of micrococcus luteus and 3 cfus of coagulase negative staph. Furthermore, your firm conducts (b)(4) surface sampling (b)(4) within the (b)(4) located in the (b)(4) (and the (b)(4)). Collecting surface samples (b)(4) does not represent environmental conditions during the aseptic operations. During this time, your firm continued to produce sterile drug products within the (b)(4) without evaluating the implication of the fungal and bacterial growth detected during the active air and surface sampling. In addition, your firm had two lots fail sterility testing in September 2016. L-Carnitine 250 mg/ml inj. lot # 09082016A (batch size: (b)(4) vials) and Glutamine/Arginine/Carnitine 25/100/200 mg/ml inj. Lot # 09152016O (batch size (b)(4) vials).
- Observation 2
Failure to conduct required sterilization procedures
Observation 2: Your firm failed to conduct (b)(4) (b)(4) (b)(4). Your firm has used this (b)(4) since approximately December 2015 to sterilize all large batches including HCG 1,000 IU inj. Lot # 08052016 A, BUD: 02/01/17 (b)(4) vials) and Testosterone Cypionate/Propionate 200 mg/50 mg/ml inj. lot # 01192016C, BUD: 07/17/16 (b)(4) vials).
Show observations 3 to 9
- Observation 3
Inadequate glove disinfection/change
Observation 3: Personnel failed to disinfect or change gloves frequently enough to prevent contamination. Specifically, on 10/13/16 during the preparation of Testosterone Propionate 100 mg/ml inj. lot # 10132016A, your firm's operator was observed entering the negative pressure clean room, touching the door handle with sterile (b)(4) gloves and without changing or disinfecting the gloves begins preparing to (b)(4). In addition, the operator began filling sterile product into the finished product vials without changing or disinfecting (b)(4) gloves. Furthermore, on 10/14/16 during the production of Methylcobalamin 1,000 mcg/ml inj. lot # 10132016F, BUD: 04/11/17 your firm's operator was observed touching the inner surfaces of the stoppers with (b)(4) gloved hand while applying them onto finished product vials.
- Observation 4
No HEPA over exposed product area
Observation 4: There is no HEPA filter (laminar air flow) over the area to which sterile product is exposed. Specifically, on 10/11/16 during the current FDA inspection, we observed Sermorel in plus 27 mg lot # 10102016K, BUD: 04/08/17 (batch size: (b)(4) vials) within the (b)(4) located in the ISO 5 negative pressure clean room. Your firm's operator stated that this lot was produced within the ISO 5 positive pressure clean room. (b)(4) stated since there was no room metering while positive pressure clean room (7XC) transported the (b)(4) vials from the positive clean room through the ante room (not under a HEPA filter) and into the negative pressure room (b)(4) (operator had to open the door to the positive pressure clean room and the door to the negative pressure clean room to place the vials into the negative pressure room (b)(4)) which in total is approximately (b)(4) distance).
- Observation 5
Stained HEPA filters not evaluated/replaced
Observation 5: The HEPA filters located in the laminar air (b)(4) Hood (b)(4) and Hood (b)(4) within the ISO 5 positive clean room contain significant brown stains. Your firm's operator stated that approximately one year ago during production within Hood (b)(4) he (b)(4) broke and the product splattered onto the HEPA filter. Your firm's operator also stated that the significant brown stains (approximately 12 x 5 inches) located in Hood (b)(4) have been that way for approximately two years. Your firm has continued to produce sterile products within Hood (b)(4) and Hood (b)(4) without evaluating the impact on product sterility and taking the appropriate corrective actions such as replacing the HEPA filters.
- Observation 6
Improper gowning and handling practices
Observation 6: Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. Specifically, a) On 10/11/16, your firm's operators were observed donning their sterile hood, sterile mask and (b)(4) goggles on with their bare hands prior to washing their hands. Both operators were also observed donning their sterile gowns on with their bare hands and leaning against the ante room wall allowing their sterile gowns to come in contact with the wall. b) On 10/14/16, your firm's operators were observed donning their sterile mask and sterile gowns with their bare hands. In addition, your firm's operators stated that they re-use their sterile gowns for one day while working on different products within the ISO 5 positive pressure clean room. They stated that when they finish a batch they will hang their sterile gowns in the ante room. In addition, on 10/14/16 during the production operations of Methylcobalamin 1,000 mcg/ml inj. lot # 10132016F, BUD: 04/11/17 your firm's operator was observed working directly over the open vials containing sterile product within the LAFW Hood therefore blocking the movement of first air around the open unit. Also, the operator's sleeve was observed touching the open finished product vials which contained sterile product potentially contaminating the batch.
- Observation 7
Non-sterile wipes used in ISO 5 hoods
Observation 7: Wipes used in the ISO 5 hoods (negative and positive pressure clean rooms) are not sterile. On 10/12/16 during the routine (b)(4) cleaning of the positive pressure ISO 5 clean room your firm's operator was observed using non-sterile wipes and spraying them with (b)(4) and (b)(4) to clean the interior surfaces of the (b)(4) LAFW hoods.
- Observation 8
Inadequate air flow in ISO 5 room
Observation 8: The ISO 5 positive pressure clean room is not operated appropriately to ensure adequate air flow within the room. Specifically, on 10/14/16 during the production of Methylcobalamin 1,000 mcg/ml inj. lot # 10132016F, BUD: 04/11/17 within the ISO 5 positive pressure clean room we observed 10 out of the (b) air return vents to be closed. Your firm's operators stated that during the cleaning of the walls some air return vents have a tendency to close.
- Observation 9
Foreign material found in released vial
Observation 9: One (1) vial out of (b)(4) vials of Calm Me Injection from Lot # 08032016C, BUD: 01/30/2017 was found to contain an unknown foreign material. Specifically, on 10/14/16 during the product inspection (released batches) of Calm Me Injection Lot # 08032016C, BUD: 01/30/2017 30 mL amber vials, we observed 1 vial out of (b)(4) vials to contain a round, white-like foreign material. According to Calm Me specifications, the amber 30 mL vial should contain a clear solution.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3011827553 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3011827553. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.